27 research outputs found
Detection tube with composite carrier for detection of phosgene and diphosgene in air
A new highly sensitive detection tube for measurement of concentration of phosgene and diphosgene in air has been developed. The detection is based on chemical reaction of 4-(p-nitrobenzyl)pyridine and N-phenylbenzylamine which with phosgene (diphosgene) give characteristic red methine dye. As a carrier serves spherical granules (pellets) of composite material prepared by granulation of microcrystalline cellulose with MgO. This new indication filling is stable, resistant to interferences and climatic influences. The detection limit (0.05 mg.m-3) meets the requirements for conducting hygienic checks of air quality in the workplace environment. In addition, the tube allows a prolonged and continuous monitoring of phosgene and diphosgene in air for at least 240 minutes
Biomedicínske použitie 3D tlače
Rešeršný článok, ktorý sa zaoberá súhrnom informácii a konkrétnych príkladov o použití 3D technológie v medicíne, farmácii a zdravotníctve. V druhej časti sú rozobraté materiály, ktoré sú najčastejšie používané, ich výhody a limitácie.235 / 5000 Výsledky překladu A research article that deals with a summary of information and specific examples of the use of 3D technology in medicine, pharmacy and healthcare. In the second part, the materials that are most often used, their advantages and limitations are discussed
Biphasic dissolution method for quality control and assurance of drugs containing active substances in the form of weak acid salts
Substances in the form of weak acid salts have been found to be problematic for dissolution testing. Their absorption can start only after they are turned into the form of an acid following the gastric passage although they were administered in the form of a salt. Due to poor solubility, they cannot be tested in acidic gastric environment for a biased dissolution profile. The biphasic dissolution method is promising for overcoming this obstacle. Tablets with warfarin clathrate sodium salt in two concentrations and two different particle size distributions were tested as a suitable model for finding the medium and process conditions of dissolution. The dissolution method based on the use of the upper organic layer (1-octanol) and the lower aqueous layer (0.1 mol L–1 HCl) was found suitable and discriminatory for tablets containing active substances in the form of salts of weak acids. The method also reflects physical differences in the quality of used substances
Carmellose mucoadhesive oral films containing vermiculite/chlorhexidine nanocomposites as innovative biomaterials for treatment of oral infections
Infectious stomatitis represents the most common oral cavity ailments. Current therapy is insufficiently effective because of the short residence time of topical liquid or semisolid medical formulations. An innovative application form based on bioadhesive polymers featuring prolonged residence time on the oral mucosa may be a solution to this challenge. This formulation consists of a mucoadhesive oral film with incorporated nanocomposite biomaterial that is able to release the drug directly at the target area. This study describes the unique approach of preparing mucoadhesive oral films from carmellose with incorporating a nanotechnologically modified clay mineral intercalated with chlorhexidine. The multivariate data analysis was employed to evaluate the influence of the formulation and process variables on the properties of the medical preparation. This evaluation was complemented by testing the antimicrobial and antimycotic activity of prepared films with the aim of finding the most suitable composition for clinical application. Generally, the best results were obtained with sample containing 20 mg of chlorhexidine diacetate carried by vermiculite, with carmellose in the form of nonwoven textile in its structure. In addition to its promising physicomechanical, chemical, and mucoadhesive properties, the formulation inhibited the growth of Staphylococcus and Candida; the effect was prolonged for tens of hours.Web of Scienceart. no. 58014
The influence of different formulations and process parameters during the preparation of drug-loaded PLGA microspheres evaluated by multivariate data analysis
The main objective of this study was to evaluate the influence of the formulation and process parameters on PLGA microparticles containing a practically insoluble model drug (ibuprofen) prepared by the o/w solvent evaporation method. Multivariate data analysis was used. The effects of altered stirring speed of a mechanical stirrer (600, 1000 rpm), emulsifier concentrations (PVA concentration 0.1 %, 1 %) and solvent selection (dichlormethane, ethyl acetate) on microparticles characteristics (encapsulation efficiency, drug loading, burst effect) were observed. It was found that with increased stirring speed, the PVA concentration or the use of ethyl acetate had a significantly negative effect on encapsulation efficiency. In addition, ethyl acetate had an adverse effect on the burst effect, while the increased stirring speed had the opposite effect. Drug load was not affected by any individual variable, but rather by the interactions of evaluated variables
Clinical testing of antiretroviral drugs as a future prevention against vaginal and rectal transmission of HIV infection – review of currently available results
The original purpose of vaginally applied microbicides was to slow down the HIV epidemic among the population until an effective vaccination was developed. Nowadays, antiretrovirals applied in the form of gels or vaginal rings are considered most prominent in this field and are tested via vaginal or, rarely, rectal applications in numerous clinical studies (9 different antiretroviral drugs in 26 clinical studies, especially in Africa). Only tenofovir (1 % gel) and dapivirine (25 mg in vaginal ring) progressed into the phase III clinical testing. Their efficiency depended on the user´s strict adherence to the application regimen (for tenofovir 54 %, for dapivirine 61 % in participants over 25 years of age). Despite this, they are expected to be important and effective tools of preventive medicine in the near future. This review summarizes the results obtained during long-term clinical testing (2005–2018) of antiretroviral drugs against vaginal and rectal transmission of HIV infection
Modern Evaluation of Liquisolid Systems with Varying Amounts of Liquid Phase Prepared Using Two Different Methods
Liquisolid systems are an innovative dosage form used for enhancing dissolution rate and improving in vivo bioavailability of poorly soluble drugs. These formulations require specific evaluation methods for their quality assurance (e.g., evaluation of angle of slide, contact angle, or water absorption ratio). The presented study is focused on the preparation, modern in vitro testing, and evaluation of differences of liquisolid systems containing varying amounts of a drug in liquid state (polyethylene glycol 400 solution of rosuvastatin) in relation to an aluminometasilicate carrier (Neusilin US2). Liquisolid powders used for the formulation of final tablets were prepared using two different methods: simple blending and spraying of drug solution onto a carrier in fluid bed equipment. The obtained results imply that the amount of liquid phase in relation to carrier material had an effect on the hardness, friability, and disintegration of tablets, as well as their height. The use of spraying technique enhanced flow properties of the prepared mixtures, increased hardness values, decreased friability, and improved homogeneity of the final dosage form
Commercially Available Enteric Empty Hard Capsules, Production Technology and Application
Currently, there is a growing need to prepare small batches of enteric capsules for individual therapy or clinical evaluation since many acidic-sensitive substances should be protected from the stomach’s acidic environment, including probiotics or fecal material, in the fecal microbiota transplantation (FMT) process. A suitable method seems to be the encapsulation of drugs or lyophilized alternatively frozen biological suspensions in commercial hard enteric capsules prepared by so-called Enteric Capsule Drug Delivery Technology (ECDDT). Manufacturers supply these types of capsules, made from pH-soluble polymers, in products such as AR Caps®, EnTRinsicTM, and Vcaps® Enteric, or capsules made of gelling polymers that release their content as the gel erodes over time when passing through the digestive tract. These include DRcaps®, EMBO CAPS® AP, BioVXR®, or ACGcaps™ HD. Although not all capsules in all formulations meet pharmaceutical requirements for delayed-release dosage forms in disintegration and dissolution tests, they usually find practical application. This literature review presents their composition and properties. Since ECDDT is a new technology, this article is based on a limited number of references
Development of a New Bioequivalent Omeprazole Product
Background and Objectives: The enteric form of omeprazole is one of the most commonly prescribed medications. Similarly to Europe, Kazakhstan relies on the localization of pharmaceutical drug production as one of its primary strategies to ensure that its population has access to affordable and good-quality medicines. This study comprehensively describes the technologically available development of bioequivalent delayed-release omeprazole. Materials and Methods: Various regimes and technological parameters were tested on laboratory- and production-scale equipment to establish a technical process where a functional and gastro-protective layer is essential. According to the ICH guidance on stability testing and Kazakhstan local rules, stability studies were conducted under conditions appropriate for climate zone II. The comparison of the rate and extent of absorption with subsequent assessment of the bioequivalence of the generic and reference drugs after a single dose of each drug at a dose of 40 mg was performed. Results: The quantitative and qualitative composition and technology of producing a new generic enteric form of omeprazole in capsules were developed and implemented at the manufacturing site of solid forms. Dissolution profiles in media with pH 1.2 and 6.8 were proven. During the accelerated six-month and long-term twelve-month studies, the developed formulation in both packaging materials at each control point passed the average weight and mass uniformity test, dissolution test, acid-resistance stage test, buffer stage test, impurity assay, and microbiological purity test and met all the specification criteria. A bioequivalence study in 24 healthy volunteers compared against the innovative drug showed the bioequivalency of the new generic system. The obtained values from the test and reference products were 1321 ± 249.0 ng/mL and 1274 ± 233 ng/mL for Cmax, 4521 ± 841 ng·h /mL and 4371 ± 695 ng·h /mL for AUC0-t, and 4636 ± 814 ng·h /mL and 4502 ± 640 ng·h /mL for AUC0-∞. Conclusions: Using affordable technologies, a bioequivalent generic delayed-release formulation of 20 and 40 mg omeprazole has been developed