40 research outputs found

    RR5. Surgical Treatment of Popliteal Aneurysms Using a Posterior Approach: Thirteen Years' Follow-up

    Get PDF
    OBJECTIVES : Long-term results of posterior approach (PA) for the treatment of popliteal artery aneurysms are lacking in the literature. We compared our results with this access with those from a standard medial approach over a 13-years\u2019 period. METHODS: Clinical data of all patients treated for a popliteal aneurysm between 2/1998 and 10/2011 were retrospectively reviewed and outcomes analyzed: Kaplan-Meier method with log-rank, chi2 and Wilcoxon test were employed for analysis. RESULTS : A total of 78 aneurysms were treated in 66 patients (65 men). Mean age was 68 years (range 48-96 years). Thirty-six aneurysms were asymptomatic (46%). Mean sac diameter was 2.9\ub11 cm. A PA was used in 43 cases (55%) and a medial approach (MA) in 35. All PA consisted in aneurysmectomy with an interposition graft with end to end anastomoses; among MA 25 interposition grafts and 10 bypass were performed. A PTFE graft was used mostly (57 cases). The two groups differed for age only (median 65.4 for PA vs. 72.9 for MA p=0.01). Five patients had an early thrombosis and required a Fogarty thrombectomy (2 PA and 3 MA, all PTFE grafts). Mortality rate at 30 days was 0%. One patient suffered a peroneal nerve lesion (permanent) and another one a major wound necrosis with tissue loss (both PA). There were no early amputations. Median follow-up was 58.8 months (range 5 days-166.7 months). Nine patients died during follow-up for unrelated causes. The 5-year primary and secondary patency rates were 58.9%\ub18,7% and 96.4%\ub13.5% respectively for PA, and 67.4%\ub110,4% and 81.3%\ub18,9% respectively for MA (p=0.41 for primary patency rate and 0.28 for secondary patency rate). Limb salvage was 100% and 93.3%\ub16.4% at 5 and 10 years respectively for PA and 91.5%\ub15.6% at both time points for MA (p=0.3). CONCLUSIONS : PA in our experience was burdened by a few more early complications compared to MA. However in the long term it provided results which compare favorably to MA. AUTHOR DISCLOSURES: I. Barbetta, Nothing to disclose; M. Carmo, Nothing to disclose; R. Dallatana, Nothing to disclose; G. Grava, Nothing to disclose; D. Mazzaccaro, Nothing to disclose; A. M. Settembrini, Nothing to disclose; P. Settembrini, Nothing to disclose

    Endovascular Treatment of Thoracic Aortic Floating Thrombus in Patients Presenting with Acute Lower Limb Ischemia

    Get PDF
    We report two cases of descending thoracic aorta floating thrombus treated with Bolton Relay thoracic free-flow stent graft. The patients had symptoms of lower limb ischemia; they underwent preoperative angiography and CTscan, then we proceeded with endovascular exclusion of the thrombus from the systemic circulation. At 12 months, the graft was still patent in both patients, without any signs of endoleak

    Venous thromboembolism and chronic venous disease among people who inject drugs: A systematic review and meta-analysis

    Full text link
    Introduction Intravenous drug use continues to pose a substantial burden worldwide and little is known about the risk of venous thromboembolism (VTE) and its sequelae in people who inject drugs (PWID). Methods A systematic literature search was conducted on the prevalence of VTE and chronic venous disease in intravenous drug users, as well as on the prevalence of intravenous drug use among selected VTE patients. Two reviewers independently selected the articles and appraised their quality. A random-effect meta-analysis was performed to pool risks across studies. Results We included 18 studies with a total of 7691 patients. The overall prevalence of VTE among PWID was 29% (95%CI: 19–40%). Among patients diagnosed with VTE, 15% (95%CI: 10–20%) were PWID. Similar rates were confirmed in more recent studies published in the past decade, although these studies are often based on the general population from higher-risk areas. Reported rates of chronic venous disease ranged between 58% and 61%. The majority of the included studies had a low to moderate quality of evidence. We could not exclude a selection bias in the studies in geographical regions with high intravenous drug use prevalence. Conclusion VTE and chronic venous disease appear to be common and understudied complications of injective drug use. National programs for PWID patients should also focus on early and late VTE-associated complications

    Endovascular treatment of iatrogenic axillary artery pseudoaneurysm under echographic control: A case report

    Get PDF
    Aim: Brief case report of the treatment of a large axillary artery pseudoaneurysm after a pacemaker using a left brachial cutdown and a retrograde delivery of a covered stent using ultrasound and fluoroscopic guidance. The patient's renal function precluded the use of contrast materials.Case Report: A 77 years old man presenting with acute renal failure and haemoglobin decrease arrived with an expanding pseudoaneurysm of the left axillary artery from a pacemaker placement. Considering the site of the lesion and patient's comorbidities, under echographic control, a Hemobahn \uae stent-graft was placed; fluoroscopy assisted manipulation of guidewires and sheaths into the aortic arch. The procedure was successfully ended without any complications. At 8 months the stent graft was still patent.Conclusion: Ultrasound guidance may represent an alternative for pseudo-aneurysm exclusion without any use of contrast medium, especially in those patient where lesions are easily detectable using ultrasonography and when comorbidities contraindicate aggressive surgical or angiographic approach

    Delayed endovascular treatment of descending aorta stent graft collapse in a patient treated for post- traumatic aortic rupture: a case report

    Get PDF
    Background: We report a case of delayed endovascular correction of graft collapse occurred after emergent Thoracic Endovascular Aortic Repair (TEVAR) for traumatic aortic isthmus rupture.Case presentation: In 7 th post-operative day after emergent TEVAR for traumatic aortic isthmus rupture (Gore TAG \uae 28-150), a partial collapse of the endoprosthesis at the descending tract occurred, with no signs of visceral ischemia. Considering patient's clinical conditions, the graft collapse wasn't treated at that time. When general conditions allowed reintervention, the patient refused any new treatment, so he was discharged.Four months later the patient complainted for severe gluteal and sural claudication, erectile disfunction and abdominal angina; endovascular correction was performed. At 18 months the graft was still patent.Discussion and Conclusion: Graft collapse after TEVAR is a rare event, which should be detected and treated as soon as possible. Delayed correction of this complication can be lethal due to the risk of visceral ischemia and limbs loss

    Guideline on carotid surgery for stroke prevention: updates from the Italian Society of Vascular and Endovascular Surgery. A trend towards personalized medicine

    Get PDF
    Background: This guideline (GL) on carotid surgery as updating of "Stroke: Italian guidelines for Prevention and Treatment" of the ISO-SPREAD Italian Stroke Organization-Group, has recently been published in the National Guideline System and shared with the Italian Society of Vascular and Endovascular Surgery (SICVE) and other Scientific Societies and Patient's Association. Methods: GRADE-SIGN version, AGREE quality of reporting checklist. Clinical questions formulated according to the PICO model. Recommendations developed based on clinical questions by a multidisciplinary experts' panel and patients' representatives. Systematic reviews performed for each PICO question. Considered judgements filled by assessing the evidence level, direction, and strength of the recommendations. Results: The panel provided indications and recommendations for appropriate, comprehensive, and individualized management of patients with carotid stenosis. Diagnostic and therapeutic processes of the best medical therapy, carotid endarterectomy (CEA), carotid stenting (CAS) according to the evidences and the judged opinions were included. Symptomatic carotid stenosis in elective and emergency, asymptomatic carotid stenosis, association with ischemic heart disease, preoperative diagnostics, types of anesthesia, monitoring in case of CEA, CEA techniques, comparison between CEA and CAS, post-surgical carotid restenosis, and medical therapy are the main topics, even with analysis of uncertainty areas for risk-benefit assessments in the individual patient (personalized medicine [PM]). Conclusions: This GL updates on the main recommendations for the most appropriate diagnostic and medical-surgical management of patients with atherosclerotic carotid artery stenosis to prevent ischemic stroke. This GL also provides useful elements for the application of PM in good clinical practice
    corecore