3 research outputs found

    Design and Validation of a Conformation Sensitive Capillary Electrophoresis-Based Mutation Scanning System and Automated Data Analysis of the More than 15 kbp-Spanning Coding Sequence of the SACS Gene

    Get PDF
    In this study, we developed and analytically validated a fully automated, robust confirmation sensitive capillary electrophoresis (CSCE) method to perform mutation scanning of the large SACS gene. This method facilitates a rapid and cost-effective molecular diagnosis of autosomal recessive spastic ataxia of Charlevoix-Saguenay. Critical issues addressed during the development of the CSCE system included the position of a DNA variant relative to the primers and the CG-content of the amplicons. The validation was performed in two phases; a retrospective analysis of 32 samples containing 41 different known DNA variants and a prospective analysis of 20 samples of patients clinically suspected of having autosomal recessive spastic ataxia of Charlevoix-Saguenay. These 20 samples appeared to contain 73 DNA variants. In total, in 32 out of the 45 amplicons, a DNA variant was present, which allowed verification of the detection capacity during the validation process. After optimization of the original design, the overall analytical sensitivity of CSCE for the SACS gene was 100%, and the analytical specificity of CSCE was 99.8%. In conclusion, CSCE is a robust technique with a high analytical sensitivity and specificity, and it can readily be used for mutation scanning of the large SACS gene. Furthermore this technique is less time-consuming and less expensive, as compared with standard automated sequencing

    A DGGE system for comprehensive mutation screening of BRCA1 and BRCA2: Application in a Dutch cancer clinic setting

    No full text
    Rapid and reliable identification of deleterious changes in the breast cancer genes BRCA1 and BRCA2 has become one of the major issues in most DNA services laboratories. To rapidly detect all possible changes within the coding and splice site determining sequences of the breast cancer genes, we established a semiautomated denaturing gradient gel electrophoresis (DGGE) mutation scanning system. All exons of both genes are covered by the DGGE scan, comprising 120 amplicons. We use a semiautomated approach, amplifying all individual amplicons with the same PCR program, after which the amplicons are pooled. DGGE is performed using three slightly different gel conditions. Validation was performed using DNA samples with known sequence variants in 107 of the 120 amplicons; all variants were detected. This DGGE mutation scanning, in combination with a PCR test for two Dutch founder deletions in BRCA1 was then applied in 431 families in which 52 deleterious changes and 70 unclassified variants were found. Fifteen unclassified variants were not reported before. The system was easily adopted by five other laboratories, where in another 3,593 families both exons 11 were analyzed by the protein truncation test (PTT) and the remaining exons by DGGE. In total, a deleterious change (nonsense, frameshift, splice-site mutation, or large deletion) was found in 661 families (16.4%), 462 in BRCA1 (11.5%), 197 in BRCA2 (4.9%), and in two index cases a deleterious change in both BRCA1 and BRCA2 was identified. Eleven deleterious changes in BRCA1 and 36 in BRCA2 had not been reported before. In conclusion, this DGGE mutation screening method for BRCA1 and BRCA2 is proven to be highly sensitive and is easy to adopt, which makes screening of large numbers of patients feasible. The results of screening of BRCA1 and BRCA2 in more than 4,000 families present a valuable overview of mutations in the Dutch population
    corecore