33 research outputs found

    Sternal plating for primary and secondary sternal closure; can it improve sternal stability?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Sternal instability with mediastinitis is a very serious complication after median sternotomy. Biomechanical studies have suggested superiority of rigid plate fixation over wire cerclage for sternal fixation. This study tests the hypothesis that sternal closure stability can be improved by adding plate fixation in a human cadaver model.</p> <p>Methods</p> <p>Midline sternotomy was performed in 18 human cadavers. Four sternal closure techniques were tested: (1) approximation with six interrupted steel wires; (2) approximation with six interrupted cables; (3) closure 1 (wires) or 2 (cables) reinforced with a transverse sternal plate at the sixth rib; (4) Closure using 4 sternal plates alone. Intrathoracic pressure was increased in all techniques while sternal separation was measured by three pairs of sonomicrometry crystals fixed at the upper, middle and lower parts of the sternum until 2.0 mm separation was detected. Differences in displacement pressures were analyzed using repeated measures ANOVA and Regression Coefficients.</p> <p>Results</p> <p>Intrathoracic pressure required to cause 2.0 mm separation increased significantly from 183.3 ± 123.9 to 301.4 ± 204.5 in wires/cables alone vs. wires/cables plus one plate respectively, and to 355.0 ± 210.4 in the 4 plates group (p < 0.05). Regression Coefficients (95% CI) were 120 (47–194) and 142 (66–219) respectively for the plate groups.</p> <p>Conclusion</p> <p>Transverse sternal plating with 1 or 4 plates significantly improves sternal stability closure in human cadaver model. Adding a single sternal plate to primary closure improves the strength of sternal closure with traditional wiring potentially reducing the risk of sternal dehiscence and could be considered in high risk patients.</p

    Fatigue testing of three peristernal median sternotomy closure techniques

    Get PDF
    Failure of a sternotomy closure because of closure system fatigue is a complication that may result in dehiscence and put the individual at risk for serious complications. The purpose of this study was to assess the fatigue performance of three peristernal median sternotomy closure techniques (figure-of-eight stainless-steel wires, figure-of-eight stainless-steel cables, or Pectofix Dynamic Sternal Fixation [DSF] stainless-steel plates) in order to quantify the potential risk of fatigue failure of these devices when subject to cyclic loads in physiologically relevant loading directions

    Compressive properties of commercially available polyurethane foams as mechanical models for osteoporotic human cancellous bone

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Polyurethane (PU) foam is widely used as a model for cancellous bone. The higher density foams are used as standard biomechanical test materials, but none of the low density PU foams are universally accepted as models for osteoporotic (OP) bone. The aim of this study was to determine whether low density PU foam might be suitable for mimicking human OP cancellous bone.</p> <p>Methods</p> <p>Quasi-static compression tests were performed on PU foam cylinders of different lengths (3.9 and 7.7 mm) and of different densities (0.09, 0.16 and 0.32 g.cm<sup>-3</sup>), to determine the Young's modulus, yield strength and energy absorbed to yield.</p> <p>Results</p> <p>Young's modulus values were 0.08–0.93 MPa for the 0.09 g.cm<sup>-3 </sup>foam and from 15.1–151.4 MPa for the 0.16 and 0.32 g.cm<sup>-3 </sup>foam. Yield strength values were 0.01–0.07 MPa for the 0.09 g.cm<sup>-3 </sup>foam and from 0.9–4.5 MPa for the 0.16 and 0.32 g.cm<sup>-3 </sup>foam. The energy absorbed to yield was found to be negligible for all foam cylinders.</p> <p>Conclusion</p> <p>Based on these results, it is concluded that 0.16 g.cm<sup>-3 </sup>PU foam may prove to be suitable as an OP cancellous bone model when fracture stress, but not energy dissipation, is of concern.</p

    Overfishing of small pelagic fishes increases trophic overlap between immature and mature striped dolphins in the Mediterranean Sea

    Get PDF
    The interactions among diet, ecology, physiology, and biochemistry affect N and C stable isotope signatures in animal tissues. Here, we examined if ecological segregation among animals in relation to sex and age existed by analyzing the signatures of δ15N and δ13C in the muscle of Western Mediterranean striped dolphins. Moreover, we used a Bayesian mixing model to study diet composition and investigated potential dietary changes over the last two decades in this population. For this, we compared isotope signatures in samples of stranded dolphins obtained during two epizootic events occurring in 1990 and 2007–2008. Mean δ13C values for females and males were not significantly different, but age-related variation indicated δ13C enrichment in both sexes, suggesting that females and males most likely fed in the same general areas, increasing their consumption of benthic prey with age. Enrichment of δ15N was only observed in females, suggesting a preference for larger or higher trophic level prey than males, which could reflect different nutritional requirements. δ13C values showed no temporal variation, although the mean δ15N signature decreased from 1990 to 2007–2008, which could indicate a dietary shift in the striped dolphin over the last two decades. The results of SIAR indicated that in 1990, hake and sardine together contributed to 60% on the diet of immature striped dolphins, and close to 90% for mature striped dolphins. Conversely, the diet of both groups in 2007–2008 was more diverse, as hake and sardine contributed to less than 40% of the entire diet. These results suggest a dietary change that was possibly related to changes in food availability, which is consistent with the depletion of sardine stocks by fishing
    corecore