106 research outputs found

    Improving the repeatability of heterochromatic flicker photometry for measurement of macular pigment optical density

    Get PDF
    Background: Heterochromatic flicker photometry (HFP) is a psychophysical technique used to measure macular pigment optical density (MPOD). We used the MPS 9000 (MPS) HFP device. Our aim was to determine if the repeatability of the MPS could be improved to make it more suitable for monitoring MPOD over time. Methods: Intra-session repeatability was assessed in 25 participants (aged 20-50 years). The resulting data was explored in detail, e.g., by examining the effect of removal and adjustment of data with less than optimal quality parameters. A protocol was developed for improved overall reliability, which was then tested in terms of inter-session repeatability in a separate group of 27 participants (aged 19-52 years). Results: Removal and adjustment of data reduced the intra-session coefficient of repeatability (CR) by 0.04, on average, and the mean individual standard deviation by 0.004. Raw data observation offered further insight into ways of improving repeatability. The proposed protocol resulted in an inter-session CR of 0.08. Conclusions: Removal and adjustment of less than optimal data improved repeatability, and is therefore recommended. To further improve repeatability, in brief we propose that each patient perform each part of the test twice, and a third time where necessary (described in detail by the protocol). Doing so will make the MPS more useful in research and clinical settings. © 2012 Springer-Verlag

    A Method of Drusen Measurement Based on the Geometry of Fundus Reflectance

    Get PDF
    BACKGROUND: The hallmarks of age-related macular degeneration, the leading cause of blindness in the developed world, are the subretinal deposits known as drusen. Drusen identification and measurement play a key role in clinical studies of this disease. Current manual methods of drusen measurement are laborious and subjective. Our purpose was to expedite clinical research with an accurate, reliable digital method. METHODS: An interactive semi-automated procedure was developed to level the macular background reflectance for the purpose of morphometric analysis of drusen. 12 color fundus photographs of patients with age-related macular degeneration and drusen were analyzed. After digitizing the photographs, the underlying background pattern in the green channel was leveled by an algorithm based on the elliptically concentric geometry of the reflectance in the normal macula: the gray scale values of all structures within defined elliptical boundaries were raised sequentially until a uniform background was obtained. Segmentation of drusen and area measurements in the central and middle subfields (1000 μm and 3000 μm diameters) were performed by uniform thresholds. Two observers using this interactive semi-automated software measured each image digitally. The mean digital measurements were compared to independent stereo fundus gradings by two expert graders (stereo Grader 1 estimated the drusen percentage in each of the 24 regions as falling into one of four standard broad ranges; stereo Grader 2 estimated drusen percentages in 1% to 5% intervals). RESULTS: The mean digital area measurements had a median standard deviation of 1.9%. The mean digital area measurements agreed with stereo Grader 1 in 22/24 cases. The 95% limits of agreement between the mean digital area measurements and the more precise stereo gradings of Grader 2 were -6.4 % to +6.8 % in the central subfield and -6.0 % to +4.5 % in the middle subfield. The mean absolute differences between the digital and stereo gradings 2 were 2.8 +/- 3.4% in the central subfield and 2.2 +/- 2.7% in the middle subfield. CONCLUSIONS: Semi-automated, supervised drusen measurements may be done reproducibly and accurately with adaptations of commercial software. This technique for macular image analysis has potential for use in clinical research

    Neurodegenerative influence of oxidative stress in the retina of a murine model of diabetes

    Get PDF
    Aims/hypothesis: Diabetic retinopathy is a progressive neuro-degenerative disease, but the underlying mechanism is still obscure. Here, we focused on oxidative stress in the retina, and analysed its influence on retinal neurodegeneration, using an antioxidant, lutein. Methods: C57BL/6 mice with streptozotocin-induced diabetes were constantly fed either a lutein-supplemented diet or a control diet from the onset of diabetes, and their metabolic data were recorded. In 1-month-diabetic mice, reactive oxygen species (ROS) in the retina were measured using dihydroethidium and visual function was evaluated by electroretinograms. Levels of activated extracellular signal-regulated kinase (ERK), synaptophysin and brain-derived neurotrophic factor (BDNF) were also measured by immunoblotting in the retina of 1-month-diabetic mice. In the retinal sections of 4-month-diabetic mice, histological changes, cleaved caspase-3 and TUNEL staining were analysed. Results: Lutein did not affect the metabolic status of the diabetic mice, but it prevented ROS generation in the retina and the visual impairment induced by diabetes. ERK activation, the subsequent synaptophysin reduction, and the BDNF depletion in the diabetic retina were all prevented by lutein. Later, in 4-month-diabetic mice, a decrease in the thickness of the inner plexiform and nuclear layers, and ganglion cell number, together with increase in cleaved caspase-3- and TUNEL-positive cells, were avoided in the retina of lutein-fed mice. Conclusions/interpretation: The results indicated that local oxidative stress that has a neurodegenerative influence in the diabetic retina is prevented by constant intake of a lutein-supplemented diet. The antioxidant, lutein may be a potential therapeutic approach to protect visual function in diabetes

    The role of the carotenoids, lutein and zeaxanthin, in protecting against age-related macular degeneration: A review based on controversial evidence

    Get PDF
    PURPOSE: A review of the role of the carotenoids, lutein and zeaxanthin, and their function in altering the pathogenesis of age-related macular degeneration (AMD). METHODS: Medline and Embase search. RESULTS: Recent evidence introduces the possibility that lutein and zeaxanthin, carotenoids found in a variety of fruits and vegetables may protect against the common eye disease of macular degeneration. This potential and the lack to slow the progression of macular degeneration, has fueled high public interest in the health benefits of these carotenoids and prompted their inclusion in various supplements. The body of evidence supporting a role in this disease ranges from basic studies in experimental animals to various other clinical and epidemiological studies. Whilst some epidemiological studies suggest a beneficial role for carotenoids in the prevention of AMD, others are found to be unrelated to it. Results of some clinical studies indicate that the risk for AMD is reduced when levels of the carotenoids are elevated in the serum or diet, but this correlation is not observed in other studies. Published data concerning the toxicity of the carotenoids or the optimum dosage of these supplements is lacking. CONCLUSION: An intake of dietary supplied nutrients rich in the carotenoids, lutein and zeaxanthin, appears to be beneficial in protecting retinal tissues, but this is not proven. Until scientifically sound knowledge is available we recommend for patients judged to be at risk for AMD to: alter their diet to more dark green leafy vegetables, wear UV protective lenses and a hat when outdoors. Future investigations on the role of nutrition, light exposure, genetics, and combinations of photodynamic therapy with intravitreal steroid (triamcinolone-acetonide) injections hold potential for future treatment possibilities

    Identifying characteristic features of the retinal and choroidal vasculature in choroideremia using optical coherence tomography angiography

    Get PDF
    PURPOSE: Using optical coherence tomography angiography (OCTA) to investigate the area with flow in the superficial retinal vessel network (SVRN) and choriocapillaris (CC) layer among male subjects with choroideremia (CHM), female carriers, and normal controls to identify vascular changes. PATIENTS AND METHODS: Images of SRVN and CC layer were acquired in 9 affected males, 5 female carriers, and 14 age- and gender-matched controls using the Angiovue software of the RTVue XR Avanti. RESULTS: The mean age was 33 years for affected male CHM patients (median 30 years), 46 years for female carriers (median 53 years), and 39 years for controls (median 38.5). Mean SRVN area±SD in subjects with CHM was 12.93±2.06 mm², in carrier subjects 15.36±0.60 mm², and in controls 15.30±1.35 mm² (P<0.01). The mean CC area±SD with flow was 6.97±5.26 mm² in CHM subjects, 21.65±0.17 mm² in carriers and 21.36±0.76 mm² in controls (P<0.01). SRVN and CC area with flow showed a negative correlation in CHM subjects with the age (r=−0.86; P<0.003 and r=−0.77; P<0.01, respectively). CC area with flow had a positive correlation with SRVN (r=0.83, P<0.001). Overall, visual acuity had a negative correlation with SRVN and CC area with flow (r=−0.67, P<0.001 and r=−0.57, P<0.002, respectively). CONCLUSIONS: This is the first study to highlight changes in the SRVN in CHM subjects. OCTA detected a reduced area with flow in both retinal and choroidal circulations, and may be a useful tool for monitoring natural history and disease progression in forthcoming clinical trials

    Effect of lutein and antioxidant dietary supplementation on contrast sensitivity in age-related macular disease:A randomized controlled trial

    Get PDF
    Objective: The aim of the study is to determine the effect of lutein combined with vitamin and mineral supplementation on contrast sensitivity in people with age-related macular disease (ARMD). Design: A prospective, 9-month, double-masked randomized controlled trial. Setting: Aston University, Birmingham, UK and a UK optometric clinical practice. Subjects: Age-related maculopathy (ARM) and atrophic age-related macular degeneration (AMD) participants were randomized (using a random number generator) to either placebo (n = 10) or active (n=15) groups. Three of the placebo group and two of the active group dropped out. Interventions: The active group supplemented daily with 6 mg lutein combined with vitamins and minerals. The outcome measure was contrast sensitivity (CS) measured using the Pelli-Robson chart, for which the study had 80% power at the 5% significance level to detect a change of 0.3log units. Results: The CS score increased by 0.07 ± 0.07 and decreased by 0.02 ± 0.18 log units for the placebo and active groups, respectively. The difference between these values is not statistically significant (z = 0.903, P = 0.376). Conclusion: The results suggest that 6 mg of lutein supplementation in combination with other antioxidants is not beneficial for this group. Further work is required to establish optimum dosage levels
    corecore