351 research outputs found

    Epidemiology and natural history of central venous access device use and infusion pump function in the NO16966 trial

    Get PDF
    Background: Central venous access devices in fluoropyrimidine therapy are associated with complications; however, reliable data are lacking regarding their natural history, associated complications and infusion pump performance in patients with metastatic colorectal cancer.<p></p> Methods: We assessed device placement, use during treatment, associated clinical outcomes and infusion pump perfomance in the NO16966 trial.<p></p> Results: Device replacement was more common with FOLFOX-4 (5-fluorouracil (5-FU)+oxaliplatin) than XELOX (capecitabine+oxaliplatin) (14.1% vs 5.1%). Baseline device-associated events and post-baseline removal-/placement-related events occurred more frequently with FOLFOX-4 than XELOX (11.5% vs 2.4% and 8.5% vs 2.1%). Pump malfunctions, primarily infusion accelerations in 16% of patients, occurred within 1.6–4.3% of cycles. Fluoropyrimidine-associated grade 3/4 toxicity was increased in FOLFOX-4-treated patients experiencing a malfunction compared with those who did not (97 out of 155 vs 452 out of 825 patients), predominantly with increased grade 3/4 neutropenia (53.5% vs 39.8%). Febrile neutropenia rates were comparable between patient cohorts±malfunction. Efficacy outcomes were similar in patient cohorts±malfunction.<p></p> Conclusions: Central venous access device removal or replacement was common and more frequent in patients receiving FOLFOX-4. Pump malfunctions were also common and were associated with increased rates of grade 3/4 haematological adverse events. Oral fluoropyrimidine-based regimens may be preferable to infusional 5-FU based on these findings

    An in vitro study comparing a peripherally inserted central catheter to a conventional central venous catheter: no difference in static and dynamic pressure transmission

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Early goal directed therapy improves survival in patients with septic shock. Central venous pressure (CVP) monitoring is essential to guide adequate resuscitation. Use of peripherally inserted central catheters (PICC) is increasing, but little data exists comparing a PICC to a conventional CVP catheter. We studied the accuracy of a novel PICC to transmit static and dynamic pressures <it>in vitro</it>.</p> <p>Methods</p> <p>We designed a device to generate controlled pressures via a column of water allowing simultaneous measurements from a PICC and a standard triple lumen catheter. Digital transducers were used to obtain all pressure readings. Measurements of static pressures over a physiologic range were recorded using 5Fr and 6Fr dual lumen PICCs. Additionally, random repetitive pressure pulses were applied to the column of water to simulate physiologic intravascular pressure variations. The resultant PICC and control waveforms were recorded simultaneously.</p> <p>Results</p> <p>Six-hundred thirty measurements were made using the 5 Fr and 6 Fr PICCs. The average bias determined by Bland-Altman plot was 0.043 mmHg for 5 Fr PICC and 0.023 mmHg for 6 Fr PICC with a difference range of 1.0 to -1.0. The correlation coefficient for both catheters was 1.0 (p-value < 0.001). Dynamic pressure waveforms plotted simultaneously between PICC and control revealed equal peaks and troughs.</p> <p>Conclusion</p> <p><it>In vitro</it>, no static or dynamic pressure differences were found between the PICC and a conventional CVP catheter. Clinical studies are required to assess whether the novel PICC has bedside equivalence to conventional catheters when measuring central venous pressures.</p

    Central venous catheter use in severe malaria: time to reconsider the World Health Organization guidelines?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To optimize the fluid status of adult patients with severe malaria, World Health Organization (WHO) guidelines recommend the insertion of a central venous catheter (CVC) and a target central venous pressure (CVP) of 0-5 cmH<sub>2</sub>O. However there are few data from clinical trials to support this recommendation.</p> <p>Methods</p> <p>Twenty-eight adult Indian and Bangladeshi patients admitted to the intensive care unit with severe <it>falciparum </it>malaria were enrolled in the study. All patients had a CVC inserted and had regular CVP measurements recorded. The CVP measurements were compared with markers of disease severity, clinical endpoints and volumetric measures derived from transpulmonary thermodilution.</p> <p>Results</p> <p>There was no correlation between the admission CVP and patient outcome (p = 0.67) or disease severity (p = 0.33). There was no correlation between the baseline CVP and the concomitant extravascular lung water (p = 0.62), global end diastolic volume (p = 0.88) or cardiac index (p = 0.44). There was no correlation between the baseline CVP and the likelihood of a patient being fluid responsive (p = 0.37). On the occasions when the CVP was in the WHO target range patients were usually hypovolaemic and often had pulmonary oedema by volumetric measures. Seven of 28 patients suffered a complication of the CVC insertion, although none were fatal.</p> <p>Conclusion</p> <p>The WHO recommendation for the routine insertion of a CVC, and the maintenance of a CVP of 0-5 cmH<sub>2</sub>O in adults with severe malaria, should be reconsidered.</p

    A Retrospective Analysis of the Haemodynamic and Metabolic Effects of Fluid Resuscitation in Vietnamese Adults with Severe Falciparum Malaria

    Get PDF
    BACKGROUND: Optimising the fluid resuscitation of patients with severe malaria is a simple and potentially cost-effective intervention. Current WHO guidelines recommend central venous pressure (CVP) guided, crystalloid based, resuscitation in adults. METHODS: Prospectively collected haemodynamic data from intervention trials in Vietnamese adults with severe malaria were analysed retrospectively to assess the responses to fluid resuscitation. RESULTS: 43 patients were studied of whom 24 received a fluid load. The fluid load resulted in an increase in cardiac index (mean increase: 0.75 L/min/m(2) (95% Confidence interval (CI): 0.41 to 1.1)), but no significant change in acid-base status post resuscitation (mean increase base deficit 0.6 mmol/L (95% CI: -0.1 to 1.3). The CVP and PAoP (pulmonary artery occlusion pressure) were highly inter-correlated (r(s) = 0.7, p<0.0001), but neither were correlated with acid-base status (arterial pH, serum bicarbonate, base deficit) or respiratory status (PaO(2)/FiO(2) ratio). There was no correlation between the oxygen delivery (DO(2)) and base deficit at the 63 time-points where they were assessed simultaneously (r(s) = -0.09, p = 0.46). CONCLUSIONS: In adults with severe falciparum malaria there was no observed improvement in patient outcomes or acid-base status with fluid loading. Neither CVP nor PAoP correlated with markers of end-organ perfusion or respiratory status, suggesting these measures are poor predictors of their fluid resuscitation needs

    Discovery of molecular hydrogen in a high-velocity cloud of the Galactic halo

    Get PDF
    We report the discovery of molecular hydrogen absorption in a Galactic high-velocity cloud (HVC) in the direction of the Large Magellanic Cloud. For the same HVC we derive an iron abundance which is half of the solar value. Thus, all evidence points to a Galactic origin for high-velocity cloud complex in front of the LMC.Comment: Published in Nature, this week; 14 pages, 3 figure

    High carriage rate of high-level penicillin-resistant Streptococcus pneumoniae in a Taiwan kindergarten associated with a case of pneumococcal meningitis

    Get PDF
    BACKGROUND: The Taiwan(19F)-14 Streptococcus pneumoniae clone and its variants are being found with increasing frequency in the Asia-Pacific region. A 5-year old child with S. pneumoniae meningitis caused by a high-level penicillin resistant strain (MIC = 4 μg/ml) was admitted to a hospital in southern Taiwan. We carried out a study to determine the potential source of this strain. METHODS: Nasopharyngeal cultures were obtained from all children attending the same kindergarten as the index case. To determine their relatedness all isolates were compared by serotype, antimicrobial susceptibility profile and pulsed field gel electrophoresis (PFGE). RESULTS: A high proportion of the children including the index case (32/78, 41.0%) carried S. pneumoniae in their nasopharynx (NP). The most common serotype was 19F (13/32, 40.6%). The PFGE types of the 19F serotype isolates obtained from the patient's blood, CSF and NP were identical and were related to 11 other serotype 19F NP isolates including 10 that were indistinguishable from the Taiwan(19F)-14 clone. All 14 isolates had similar high-level penicillin and multi-drug resistance. The serotypes of the other 19 NP isolates included 6A (2), 6B (10), 23F (5), 9V (1) and 3 (1). The overall rate of penicillin resistance in these S. pneumoniae from these children was 87.5% (28/32), with an MIC(50 )of 2 and MIC(90 )of 4 ug/ml. In addition, multi-drug resistant-isolates (isolates resistant to 3 different classes of antimicrobials) accounted for 87.5% (28/32) of all isolates. CONCLUSION: The high carriage rate of high-level penicillin- and multi-drug- resistant S. pneumoniae in a kindergarten associated with a case of pneumococcal meningitis emphasizes the need for restraint in antibiotic use and consideration of childhood immunization with conjugate pneumococcal vaccine to prevent the further spread of resistant S. pneumoniae in Taiwan

    Catheter Related Bloodstream Infection (CR-BSI) in ICU Patients: Making the Decision to Remove or Not to Remove the Central Venous Catheter

    Get PDF
    Background Approximately 150 million central venous catheters (CVC) are used each year in the United States. Catheter-related bloodstream infections (CR-BSI) are one of the most important complications of the central venous catheters (CVCs). Our objective was to compare the in-hospital mortality when the catheter is removed or not removed in patients with CR-BSI. Methods We reviewed all episodes of CR-BSI that occurred in our intensive care unit (ICU) from January 2000 to December 2008. The standard method was defined as a patient with a CVC and at least one positive blood culture obtained from a peripheral vein and a positive semi quantitative (\u3e15 CFU) culture of a catheter segment from where the same organism was isolated. The conservative method was defined as a patient with a CVC and at least one positive blood culture obtained from a peripheral vein and one of the following: (1) differential time period of CVC culture versus peripheral culture positivity of more than 2 hours, or (2) simultaneous quantitative blood culture with 5:1 ratio (CVC versus peripheral). Results 53 CR-BSI (37 diagnosed by the standard method and 16 by the conservative method) were diagnosed during the study period. There was a no statistically significant difference in the in-hospital mortality for the standard versus the conservative method (57% vs. 75%, p = 0.208) in ICU patients. Conclusion In our study there was a no statistically significant difference between the standard and conservative methods in-hospital mortality

    Prevention of catheter lumen occlusion with rT-PA versus heparin (Pre-CLOT): study protocol of a randomized trial [ISRCTN35253449]

    Get PDF
    BACKGROUND: Many patients with end-stage renal disease use a central venous catheter for hemodialysis access. A large majority of these catheters malfunction within one year of insertion, with up to two-thirds due to thrombosis. The optimal solution for locking the catheter between hemodialysis sessions, to decrease the risk of thrombosis and catheter malfunction, is unknown. The Prevention of Catheter Lumen Occlusion with rt-PA versus Heparin (PreCLOT) study will determine if use of weekly rt-PA, compared to regular heparin, as a catheter locking solution, will decrease the risk of catheter malfunction. METHODS/DESIGN: The study population will consist of patients requiring chronic hemodialysis thrice weekly who are dialyzed with a newly inserted permanent dual-lumen central venous catheter. Patients randomized to the treatment arm will receive rt-PA 1 mg per lumen once per week, with heparin 5,000 units per ml as a catheter locking solution for the remaining two sessions. Patients randomized to the control arm will receive heparin 5,000 units per ml as a catheter locking solution after each dialysis session. The study treatment period will be six months, with 340 patients to be recruited from 14 sites across Canada. The primary outcome will be catheter malfunction, based on mean blood flow parameters while on hemodialysis, with a secondary outcome of catheter-related bacteremia. A cost-effectiveness analysis will be undertaken to assess the cost of maintaining a catheter using rt-PA as a locking solution, compared to the use of heparin. DISCUSSION: Results from this study will determine if use of weekly rt-PA, compared to heparin, will decrease catheter malfunction, as well as assess the cost-effectiveness of these locking solutions

    Rural–Urban Migration and Experience of Childhood Abuse in the Young Thai Population

    Get PDF
    Evidence suggests that certain migrant populations are at increased risk of abusive behaviors. It is unclear whether this may also apply to Thai rural–urban migrants, who may experience higher levels of psychosocial adversities than the population at large. The study aims to examine the association between migration status and the history of childhood sexual, physical, and emotional abuse among young Thai people in an urban community. A population-based cross-sectional survey was conducted in Northern Bangkok on a representative sample of 1052 young residents, aged 16–25 years. Data were obtained concerning: 1) exposures—migration (defined as an occasion when a young person, born in a more rural area moves for the first time into Greater Bangkok) and age at migration. 2) outcomes—child abuse experiences were assessed with an anonymous self report adapted from the Conflict Tactics Scales (CTS). There were 8.4%. 16.6% and 56.0% reporting sexual, physical, and emotional abuse, respectively. Forty six percent of adolescents had migrated from rural areas to Bangkok, mostly independently at the age of 15 or after to seek work. Although there were trends towards higher prevalences of the three categories of abuse among early migrants, who moved to Bangkok before the age of 15, being early migrants was independently associated with experiences of physical abuse (OR 1.9 95%CI 1.1–3.2) and emotional abuse (OR 2.0, 95%CI 1.3–3.0) only. Our results suggest that rural–urban migration at an early age may place children at higher risk of physical and emotional abuse. This may have policy implications for the prevention of childhood abuse particularly among young people on the move
    corecore