17 research outputs found

    Pharmacokinetic/pharmacodynamic relationships of antimicrobial drugs used in veterinary medicine

    No full text
    The rise in incidence of antimicrobial resistance, consumer demands and improved understanding of antimicrobial action has encouraged international agencies to review the use of antimicrobial drugs. More detailed understanding of relationships between the pharmacokinetics (PK) of antimicrobial drugs in target animal species and their action on target pathogens [pharmacodynamics (PD)] has led to greater sophistication in design of dosage schedules which improve the activity and reduce the selection pressure for resistance in antimicrobial therapy. This, in turn, may be informative in the pharmaceutical development of antimicrobial drugs and in their selection and clinical utility. PK/PD relationships between area under the concentration time curve from zero to 24 h (AUC(0-24)) and minimum inhibitory concentration (MIC), maximum plasma concentration and MIC and time during which plasma concentrations exceed the MIC have been particularly useful in optimizing efficacy and minimizing resistance. Antimicrobial drugs have been classified as concentration-dependent where increasing concentrations at the locus of infection improve bacterial kill, or time-dependent where exceeding the MIC for a prolonged percentage of the inter-dosing interval correlates with improved efficacy. For the latter group increasing the absolute concentration obtained above a threshold does not improve efficacy. The PK/PD relationship for each group of antimicrobial drugs is 'bug and drug' specific, although ratios of 125 for AUC(0-24):MIC and 10 for C-max:MIC have been recommended to achieve high efficacy for concentration-dependent antimicrobial drugs, and exceeding MIC by 1-5 multiples for between 40 and 100% of the inter-dosing interval is appropriate for most time-dependent agents. Fluoroquinolones, aminoglycosides and metronidazole are concentration-dependent and beta-lactams. macrolides, lincosamides and glycopeptides are time-dependent. For drugs of other classes there is limited and conflicting information on their classification. Resistance selection may be reduced for concentration-dependent antimicrobials by achieving an AUC(0-24):MIC ratio of greater than 100 or a C-max:MIC ratio of greater than 8. The relationships between time greater than MIC and resistance selection for time-dependent antimicrobials have not been well characterized.Peer reviewe

    EXILL—a high-efficiency, high-resolution setup for γ\gamma-spectroscopy at an intense cold neutron beam facility

    Get PDF
    In the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of γ-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 10(8) n s(−)(1)cm(−)(2) at the target position and negligible neutron halo. The target was surrounded by an array of eight to ten anti-Compton shielded EXOGAM Clover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the campaign the array was combined with 16 LaBr(3):(Ce) detectors from the FATIMA collaboration. The detectors were arranged in an array of rhombicuboctahedron geometry, providing the possibility to carry out very precise angular correlation and directional-polarization correlation measurements. The triggerless acquisition system allowed a signal collection rate of up to 6 × 10(5) Hz. The data allowed to set multi-fold coincidences to obtain decay schemes and in combination with the FATIMA array of LaBr(3):(Ce) detectors to analyze half-lives of excited levels in the pico- to microsecond range. Precise energy and efficiency calibrations of EXILL were performed using standard calibration sources of (133)Ba, (60)Co and (152)Eu as well as data from the reactions (27)Al(n,γ)(28)Al and (35)Cl(n,γ)(36)Cl in the energy range from 30 keV up to 10 MeV

    EXILL—a high-efficiency, high-resolution setup for γ-spectroscopy at an intense cold neutron beam facility

    No full text
    In the EXILL campaign a highly efficient array of high purity germanium (HPGe) detectors was operated at the cold neutron beam facility PF1B of the Institut Laue-Langevin (ILL) to carry out nuclear structure studies, via measurements of γ-rays following neutron-induced capture and fission reactions. The setup consisted of a collimation system producing a pencil beam with a thermal capture equivalent flux of about 108 n s−1cm−2 at the target position and negligible neutron halo. The target was surrounded by an array of eight to ten anti-Compton shielded EXOGAM Clover detectors, four to six anti-Compton shielded large coaxial GASP detectors and two standard Clover detectors. For a part of the campaign the array was combined with 16 LaBr3:(Ce) detectors from the FATIMA collaboration. The detectors were arranged in an array of rhombicuboctahedron geometry, providing the possibility to carry out very precise angular correlation and directional-polarization correlation measurements. The triggerless acquisition system allowed a signal collection rate of up to 6 × 105 Hz. The data allowed to set multi-fold coincidences to obtain decay schemes and in combination with the FATIMA array of LaBr3:(Ce) detectors to analyze half-lives of excited levels in the pico- to microsecond range. Precise energy and efficiency calibrations of EXILL were performed using standard calibration sources of 133Ba, 60Co and 152Eu as well as data from the reactions 27Al(n,γ)28Al and 35Cl(n,γ)36Cl in the energy range from 30 keV up to 10 MeV

    Mouse Chromosome 9

    No full text

    Mouse chromosome 9

    No full text
    corecore