9,814 research outputs found

    Single-color two-photon spectroscopy of Rydberg states in electric fields

    Get PDF
    Rydberg states of atomic helium with principal quantum numbers ranging from n=20 to n=100 have been prepared by non-resonance-enhanced single-color two-photon excitation from the metastable 2 {^3}S{_1} state. Photoexcitation was carried out using linearly and circularly polarized pulsed laser radiation. In the case of excitation with circularly polarized radiation, Rydberg states with azimuthal quantum number |m_{\ell}|=2 were prepared in zero electric field, and in homogeneous electric fields oriented parallel to the propagation axis of the laser radiation. In sufficiently strong electric fields, individual Rydberg-Stark states were resolved spectroscopically, highlighting the suitability of non-resonance-enhanced multiphoton excitation schemes for the preparation of long-lived high-|m_{\ell}| hydrogenic Rydberg states for deceleration and trapping experiments. Applications of similar schemes for Doppler-free excitation of positronium atoms to Rydberg states are also discussed

    Conclusion of Viking Lander Imaging Investigation: Picture catalog of experiment data record

    Get PDF
    The images returned by the two Viking landers during the Viking Survey Mission are presented in this report. Listing of supplemental information which describe the conditions under which the images were acquired are included. Subsets of the images are listed in a variety of sequences to aid in locating images of interest. The format and organization of the digital magnetic tape storage of the images are described. A brief description of the mission and the camera system is also included

    Reflectance characteristics of the Viking lander camera reference test charts

    Get PDF
    Reference test charts provide radiometric, colorimetric, and spatial resolution references for the Viking lander cameras on Mars. Reflectance measurements of these references are described, including the absolute bidirectional reflectance of the radiometric references and the relative spectral reflectance of both radiometric and colorimetric references. Results show that the bidirection reflectance of the radiometric references is Lambertian to within + or - 7% for incidence angles between 20 deg and 60 deg, and that their spectral reflectance is constant with wavelength to within + or - 5% over the spectral range of the cameras. Estimated accuracy of the measurements is + or - 0.05 in relative spectral reflectance

    A filter spectrometer concept for facsimile cameras

    Get PDF
    A concept which utilizes interference filters and photodetector arrays to integrate spectrometry with the basic imagery function of a facsimile camera is described and analyzed. The analysis considers spectral resolution, instantaneous field of view, spectral range, and signal-to-noise ratio. Specific performance predictions for the Martian environment, the Viking facsimile camera design parameters, and a signal-to-noise ratio for each spectral band equal to or greater than 256 indicate the feasibility of obtaining a spectral resolution of 0.01 micrometers with an instantaneous field of view of about 0.1 deg in the 0.425 micrometers to 1.025 micrometers range using silicon photodetectors. A spectral resolution of 0.05 micrometers with an instantaneous field of view of about 0.6 deg in the 1.0 to 2.7 micrometers range using lead sulfide photodetectors is also feasible

    An investigation of the facsimile camera response to object motion

    Get PDF
    A general analytical model of the facsimile camera response to object motion is derived as an initial step toward characterizing the resulting image degradation. This model expresses the spatial convolution of a time-varying object radiance distribution and camera point-spread function for each picture element in the image. Time variations and these two functions during each convolution account for blurring of small image detail, and variations between, as well as during, successive convolutions account for geometric image distortions. If the object moves beyond the angular extent of several picture elements while it is being imaged, then geometric distortion tends to dominate blurring as the primary cause of image degradation. The extent of distortion depends not only on object size and velocity but also on the direction of object motion, and is therefore difficult to classify in a general sense

    Optical analysis of a compound quasi-microscope for planetary landers

    Get PDF
    A quasi-microscope concept, consisting of facsimile camera augmented with an auxiliary lens as a magnifier, was introduced and analyzed. The performance achievable with this concept was primarily limited by a trade-off between resolution and object field; this approach leads to a limiting resolution of 20 microns when used with the Viking lander camera (which has an angular resolution of 0.04 deg). An optical system is analyzed which includes a field lens between camera and auxiliary lens to overcome this limitation. It is found that this system, referred to as a compound quasi-microscope, can provide improved resolution (to about 2 microns ) and a larger object field. However, this improvement is at the expense of increased complexity, special camera design requirements, and tighter tolerances on the distances between optical components

    Mediators of mechanotransduction between bone cells

    Get PDF
    Mechanical forces are known to regulate the function of tissues in the body, including bone. Bone adapts to its mechanical environment by altering its shape and increasing its size in response to increases in mechanical load associated with exercise, and by decreasing its size in response to decreases in mechanical load associated with microgravity or prolonged bed rest. Changes in bone size and shape are produced by a cooperative action of two main types of the bone cells - osteoclasts that destroy bone and osteoblasts that build bone. These cell types come from different developmental origins, and vary greatly in their characteristics, such as size, shape, and expression of receptor subtypes, which potentially may affect their responses to mechanical stimuli. The objective of this study is to compare the responses of osteoclasts and osteoblasts to mechanical stimulation. This study has allowed us to conclude the following: 1. A mediator is released from a single source cell. 2. The response to the mediator changes with distance. 3. The value of the apparent diffusion coeficient increases with distance. 4. A plausible proposed mechanism is that ATP is released and degrades to ADP. 5. Future experiments are required to confim that ATP is the mediator as suggested

    Prediction of Viking lander camera image quality

    Get PDF
    Formulations are presented that permit prediction of image quality as a function of camera performance, surface radiance properties, and lighting and viewing geometry. Predictions made for a wide range of surface radiance properties reveal that image quality depends strongly on proper camera dynamic range command and on favorable lighting and viewing geometry. Proper camera dynamic range commands depend mostly on the surface albedo that will be encountered. Favorable lighting and viewing geometries depend mostly on lander orientation with respect to the diurnal sun path over the landing site, and tend to be independent of surface albedo and illumination scattering function. Side lighting with low sun elevation angles (10 to 30 deg) is generally favorable for imaging spatial details and slopes, whereas high sun elevation angles are favorable for measuring spectral reflectances

    Performance evaluation of a quasi-microscope for planetary landers

    Get PDF
    Spatial resolutions achieved with cameras on lunar and planetary landers have been limited to about 1 mm, whereas microscopes of the type proposed for such landers could have obtained resolutions of about 1 um but were never accepted because of their complexity and weight. The quasi-microscope evaluated in this paper could provide intermediate resolutions of about 10 um with relatively simple optics that would augment a camera, such as the Viking lander camera, without imposing special design requirements on the camera of limiting its field of view of the terrain. Images of natural particulate samples taken in black and white and in color show that grain size, shape, and texture are made visible for unconsolidated materials in a 50- to 500-um size range. Such information may provide broad outlines of planetary surface mineralogy and allow inferences to be made of grain origin and evolution. The mineralogical descriptions of single grains would be aided by the reflectance spectra that could, for example, be estimated from the six-channel multispectral data of the Viking lander camera

    A reliable Pade analytical continuation method based on a high accuracy symbolic computation algorithm

    Full text link
    We critique a Pade analytic continuation method whereby a rational polynomial function is fit to a set of input points by means of a single matrix inversion. This procedure is accomplished to an extremely high accuracy using a novel symbolic computation algorithm. As an example of this method in action we apply it to the problem of determining the spectral function of a one-particle thermal Green's function known only at a finite number of Matsubara frequencies with two example self energies drawn from the T-matrix theory of the Hubbard model. We present a systematic analysis of the effects of error in the input points on the analytic continuation, and this leads us to propose a procedure to test quantitatively the reliability of the resulting continuation, thus eliminating the black magic label frequently attached to this procedure.Comment: 11 pages, 8 eps figs, revtex format; revised version includes reference to anonymous ftp site containing example codes (MapleVr5.1 worksheets) displaying the implementation of the algorithm, including the padematinv.m library packag
    • …
    corecore