1,175 research outputs found
Electronic structure of C60 / graphite
We report temperature-dependent photoelectron spectra for a monolayer of C_60
adsorbed on HOPG, as well as C 1s x-ray absorption. This extends a previous
report which showed the close similarity between the spectrum of the HOMO for
the two-dimensional overlayer and that of C_60 in the gas phase. The present
work shows that intermolecular and molecule-substrate vibrations contribute
strongly to the spectral lineshape at room temperature. Thus, vibrational
effects are shown to be crucial for the proper understanding of photoelectron
spectra, and thus the charge transport properties, for C_60 in contact with
graphite and graphite-like materials.Comment: Proc. of the XV. Int. Winterschool on Electronic Properties of Novel
Materials, Kirchberg/Tirol, Austria, 200
Element specific characterization of heterogeneous magnetism in (Ga,Fe)N films
We employ x-ray spectroscopy to characterize the distribution and magnetism
of particular alloy constituents in (Ga,Fe)N films grown by metal organic vapor
phase epitaxy. Furthermore, photoelectron microscopy gives direct evidence for
the aggregation of Fe ions, leading to the formation of Fe-rich nanoregions
adjacent to the samples surface. A sizable x-ray magnetic circular dichroism
(XMCD) signal at the Fe L-edges in remanence and at moderate magnetic fields at
300 K links the high temperature ferromagnetism with the Fe(3d) states. The
XMCD response at the N K-edge highlights that the N(2p) states carry
considerable spin polarization. We conclude that FeN{\delta} nanocrystals, with
\delta > 0.25, stabilize the ferromagnetic response of the films.Comment: 4 pages, 3 figures, 1 tabl
Dynamic range and mass accuracy of wide-scan direct infusion nanoelectrospray fourier transform ion cyclotron resonance mass spectrometry-based metabolomics increased by the spectral stitching method
Direct infusion nanoelectrospray Fourier transform ion cyclotron resonance mass spectrometry (DI nESI FT-ICR MS)offers high mass accuracy and resolution for analyzing complex metabolite mixtures. High dynamic range across a wide mass range, however, can only be achieved at the expense of mass accuracy, since the large numbers of ions entering the ICR detector induce adverse spacecharge effects. Here we report an optimized strategy for wide-scan DI nESI FT-ICR MS that increases dynamic range but maintains high mass accuracy. It comprises the collection if multiple adjacent selected ion monitoring (SIM) windows that are stitched together using novel algorithms. The final SIM-stitching method, derived from several optimization experiments, comprises 21 adjoining SIM windows each of width m/z 30 (from m/z 70 to 500; adjacent windows overlap by m/z 10) with an automated gain control (AGC) target of 1 105 charges. SIMstitching and wide-scan range (WSR; Thermo Electron)were compared using a defined standard to assess mass accuracy and a liver extract to assess peak count and dynamic range. SIM-stitching decreased the maximum mass error by 1.3- and 4.3-fold, and increased the peak count by 5.3- and 1.8-fold, versus WSR (AGC targets of 1 x 105 and 5 x 105, respectively). SIM-stitching achieved an rms mass error of 0.18 ppm and detected over 3000 peaks in liver extract. This novel approach increases metabolome coverage, has very high mass accuracy, and at 5.5 min/sample is conducive for high- throughput metabolomics
Optimized Perturbation Theory for Wave Functions of Quantum Systems
The notion of the optimized perturbation, which has been successfully applied
to energy eigenvalues, is generalized to treat wave functions of quantum
systems. The key ingredient is to construct an envelope of a set of
perturbative wave functions. This leads to a condition similar to that obtained
from the principle of minimal sensitivity. Applications of the method to
quantum anharmonic oscillator and the double well potential show that uniformly
valid wave functions with correct asymptotic behavior are obtained in the
first-order optimized perturbation even for strong couplings.Comment: 11 pages, RevTeX, three ps figure
Direct observation of frozen moments in the NiFe/FeMn exchange bias system
We detect the presence of frozen magnetic moments in an exchange biased NiFe ferromagnet at the NiFe/FeMn ferromagnet/antiferromagnet interface by magnetic circular dichroism in x-ray absorption and resonant reflectivity experiments. Frozen moments are detected by means of the element-specific hysteresis loops. A weak dichroic absorption with unidirectional anisotropy can be linked to frozen magnetic moments in the ferromagnet. A more pronounced exchange bias for increasing the thickness of the FeMn layer correlates with an increase in orbital moment for interface Ni atoms carrying a frozen moment. These atoms compose about a single monolayer, but only a fraction of the atoms contributes by means of a strongly enhanced orbital moment to the macroscopic exchange bias phenomenon. The microscopic spin-orbit energy associated with these few interface frozen moment atoms appears to be sufficient to account for the macroscopic exchange bias energ
Direct observation of frozen moments in the NiFe/FeMn exchange bias system
We detect the presence of frozen magnetic moments in an exchange biased NiFe ferromagnet at the NiFe/FeMn ferromagnet/antiferromagnet interface by magnetic circular dichroism in x-ray absorption and resonant reflectivity experiments. Frozen moments are detected by means of the element-specific hysteresis loops. A weak dichroic absorption with unidirectional anisotropy can be linked to frozen magnetic moments in the ferromagnet. A more pronounced exchange bias for increasing the thickness of the FeMn layer correlates with an increase in orbital moment for interface Ni atoms carrying a frozen moment. These atoms compose about a single monolayer, but only a fraction of the atoms contributes by means of a strongly enhanced orbital moment to the macroscopic exchange bias phenomenon. The microscopic spin-orbit energy associated with these few interface frozen moment atoms appears to be sufficient to account for the macroscopic exchange bias energ
Controlled Ultrasound-Induced Blood-Brain Barrier Disruption Using Passive Acoustic Emissions Monitoring
The ability of ultrasonically-induced oscillations of circulating microbubbles to permeabilize vascular barriers such as the blood-brain barrier (BBB) holds great promise for noninvasive targeted drug delivery. A major issue has been a lack of control over the procedure to ensure both safe and effective treatment. Here, we evaluated the use of passively-recorded acoustic emissions as a means to achieve this control. An acoustic emissions monitoring system was constructed and integrated into a clinical transcranial MRI-guided focused ultrasound system. Recordings were analyzed using a spectroscopic method that isolates the acoustic emissions caused by the microbubbles during sonication. This analysis characterized and quantified harmonic oscillations that occur when the BBB is disrupted, and broadband emissions that occur when tissue damage occurs. After validating the system's performance in pilot studies that explored a wide range of exposure levels, the measurements were used to control the ultrasound exposure level during transcranial sonications at 104 volumes over 22 weekly sessions in four macaques. We found that increasing the exposure level until a large harmonic emissions signal was observed was an effective means to ensure BBB disruption without broadband emissions. We had a success rate of 96% in inducing BBB disruption as measured by in contrast-enhanced MRI, and we detected broadband emissions in less than 0.2% of the applied bursts. The magnitude of the harmonic emissions signals was significantly (P<0.001) larger for sonications where BBB disruption was detected, and it correlated with BBB permeabilization as indicated by the magnitude of the MRI signal enhancement after MRI contrast administration (R2 = 0.78). Overall, the results indicate that harmonic emissions can be a used to control focused ultrasound-induced BBB disruption. These results are promising for clinical translation of this technology
The Impact of Antimicrobial Resistance and Aging in VAP Outcomes: Experience from a Large Tertiary Care Center
Background: Ventilator associated pneumonia (VAP) is a serious infection among patients in the intensive care unit (ICU). Methods: We reviewed the medical charts of all patients admitted to the adult intensive care units of the Massachusetts General Hospital that went on to develop VAP during a five year period. Results: 200 patients were included in the study of which 50 (25%) were infected with a multidrug resistant pathogen. Increased age, dialysis and late onset (≥5 days from admission) VAP were associated with increased incidence of resistance. Multidrug resistant bacteria (MDRB) isolation was associated with a significant increase in median length of ICU stay (19 vs. 16 days, p = 0.02) and prolonged duration of mechanical ventilation (18 vs. 14 days, p = 0.03), but did not impact overall mortality (HR 1.12, 95% CI 0.51–2.46, p = 0.77). However, age (HR 1.04 95% CI 1.01–1.07, p = 0.003) was an independent risk factor for mortality and age ≥65 years was associated with increased incidence of methicillin-resistant Staphylococcus aureus (MRSA) infections (OR 2.83, 95% CI 1.27–6.32, p = 0.01). Conclusions: MDRB-related VAP is associated with prolonged ICU stay and mechanical ventilation. Interestingly, age ≥ 65 years is associated with MRSA VAP
Dynamical mass generation by source inversion: Calculating the mass gap of the Gross-Neveu model
We probe the U(N) Gross-Neveu model with a source-term . We
find an expression for the renormalization scheme and scale invariant source
, as a function of the generated mass gap. The expansion of this
function is organized in such a way that all scheme and scale dependence is
reduced to one single parameter d. We get a non-perturbative mass gap as the
solution of . In one loop we find that any physical choice for d
gives good results for high values of N. In two loops we can determine d
self-consistently by the principle of minimal sensitivity and find remarkably
accurate results for N>2.Comment: 13 pages, 3 figures, added referenc
- …
