303 research outputs found

    Method and apparatus for controlling an earthworking implement to preserve a crown on a road surface

    Get PDF
    A method and apparatus for controlling an earthworking implement on an earthworking machine to preserve a crown on the surface of a road, including determining the position of the crown on the road surface, choosing a sloped grade on one side of the crown, positioning the earthworking implement on the sloped grade so that a first end of the earthworking implement is on the road surface. The processor determines a desired position of a second end of the earthworking implement so that the second end overlaps the crown and the earthworking implement does not cut the crown

    Longitudinal Momentum Fraction X_L for Two High P_t Protons in pp->ppX Reaction

    Full text link
    We present an analysis of new data from Experiment E850 at BNL. We have characterized the inclusive cross section near the endpoint for pp exclusive scattering in Hydrogen and in Carbon with incident beam energy of 6 GeV. We select events with a pair of back-to-back hadrons at large transverse momentum. These cross sections are parameterized with a form dσdXL\frac{d \sigma}{d X_{L}} (1XL)p\sim(1-X_{L})^{p}, where XL{X_{L}} is the ratio of the longitudinal momentum of the observed pair to the total incident beam momentum. Small value of pp may suggest that the number of partons participating in the reaction is large and reaction has a strong dependence on the center-of-mass energy. We also discuss nuclear effects observed in our kinematic region.Comment: 4 pages, 2 figures, to be published in Proceedings of CIPANP2000, Quebec, May 22-28, 2000, requires aipproc.sty(included

    Presentation and management of keloid scarring following median sternotomy: a case study

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Keloid scars following median sternotomy are rare and occur more frequently in pigmented skin. Different management strategies have been described with variable success. We present a case of keloid scar formation following cardiac surgery including our management and the final aesthetic result.</p> <p>Case description</p> <p>A 64 year old female of fair complexion underwent mitral valve replacement. The procedure and postoperative recovery were uncomplicated, however, during the following year, thick keloid scars formed over the incision sites. Initial non surgical measures failed to relieve pain and did not offer any tangible aesthetic benefit. Eventually surgical excision was attempted. She presented to our clinic for nine months follow up with significant improvement in pain and aesthetic result.</p> <p>Discussion and Evaluation</p> <p>Several theories have attempted to explore the pathophysiology of keloid scar formation. A number of predisposing factors have been documented however none existed in this case. A variety of invasive and non invasive approaches have been described but significant differences in success rates and methodology of investigations still precludes a standardized management protocol.</p> <p>Conclusions</p> <p>In this case study a rare presentation of keloid scar has been presented. The variety of methods used to improve pain and aesthetic result demonstrates the propensity of keloid scars to recur and the therapeutic challenges that surgeons have to face in their quest for a satisfactory patient outcome.</p

    Measurement of quasi-elastic 12C(p,2p) scattering at high momentum transfer

    Full text link
    We measured the high-momentum quasi-elastic 12C(p,2p) reaction (at center of mass angle near 90 degrees) for 6 and 7.5 GeV/c incident protons. The three-momentum components of both final state protons were measured and the missing energy and momentum of the target proton in the nucleus were determined. The validity of the quasi-elastic picture was verified up to Fermi momenta of about 450 MeV/c, where it might be questionable. Transverse and longitudinal Fermi momentum distributions of the target proton were measured and compared to independent particle models which do not reproduce the large momentum tails. We also observed that the transverse Fermi distribution gets wider as the longitudinal component increases in the beam direction, in contrast to a simple Fermi gas model.Comment: 4 pages including 3 figure

    Spatially Resolved Ultrasound Diagnostics of Li-Ion Battery Electrodes

    Get PDF
    The importance of reliable battery diagnostic systems has grown substantially in recent years as a result of the use of high power Li-ion battery packs in an increasingly diverse range of applications. Here, spatially resolved ultrasound acoustic measurements are used to analyse the condition of Li-ion electrodes. Ultrasonic measurements are performed on a commercial mobile phone battery over the full operating voltage window with the lithiation and delithiation of electrodes observed at 36 locations on the surface of the cell. X-ray computed tomography was performed on the cell to ascertain the internal architecture and features that enabled the architecture of the battery to be correlated with the acoustic signature. Analyses of the acoustic signals obtained suggest that the anode and cathode layers can be identified by examining the change in attenuation associated with the charging process. It is also seen that expansions of the electrode layers are inhibited by the presence of the anode current collecting tab in the battery which leads to spatial inhomogeneities in the expansion of the electrode layer examined within the cell

    Energy Dependence of Nuclear Transparency in C(p,2p) Scattering

    Get PDF
    The transparency of carbon for (p,2p) quasi-elastic events was measured at beam energies ranging from 6 to 14.5 GeV at 90 degrees c.m. The four momentum transfer squared q*q ranged from 4.8 to 16.9 (GeV/c)**2. We present the observed energy dependence of the ratio of the carbon to hydrogen cross sections. We also apply a model for the nuclear momentum distribution of carbon to normalize this transparency ratio. We find a sharp rise in transparency as the beam energy is increased to 9 GeV and a reduction to approximately the Glauber level at higher energies.Comment: 4 pages, 2figures, submitted to PR
    corecore