441 research outputs found
Design considerations for the beam-waveguide retrofit of a ground antenna station
Retrofitting an antenna that was originally designed without a beam waveguide introduces special difficulties because it is desirable to minimize alteration of the original mechanical truss work and to image the actual feed without distortion at the focal point of the dual-shaped reflector. To obtain an acceptable image, certain Geometrical Optics (GO) design criteria are followed as closely as possible. The problems associated with applying these design criteria to a 34-meter dual-shaped DSN (Deep Space Network) antenna are discussed. The use of various diffraction analysis techniques in the design process is also discussed. GTD and FFT algorithms are particularly necessary at the higher frequencies, while Physical Optics and Spherical Wave Expansions proved necessary at the lower frequencies
Performance of horn-coupled transition edge sensors for L- and S-band optical detection on the SAFARI instrument
We describe the geometry, architecture, dark- and optical performance of ultra-low-noise transition edge sensors as THz detectors for the SAFARI instrument. The TESs are fabricated from superconducting Mo/Au bilayers coupled to impedance-matched superconducting ß-phase Ta thin-film absorbers. The detectors have phonon-limited dark noise equivalent powers of order 0.5 - 1.0 aW/ and saturation powers of order 20 - 40 fW. The low temperature test configuration incorporating micro-machined backshorts is also described, and construction and typical performance characteristics for the optical load are shown. We report preliminary measurements of the optical performance of these TESs for two SAFARI bands; L-band at 110 - 210 µm and S-band 34 - 60 µm .European Space AgencyThis is the final version of the article. It first appeared from SPIE via http://dx.doi.org/10.1117/12.223274
Simulation of sub-millimetre atmospheric spectra for characterizing potential ground-based remote sensing observations
The sub-millimetre is an understudied region of the Earth's atmospheric electromagnetic spectrum. Prior technological gaps and relatively high opacity due to the prevalence of rotational water vapour lines at these wavelengths have slowed progress from a ground-based remote sensing perspective; however, emerging superconducting detector technologies in the fields of astronomy offer the potential to address key atmospheric science challenges with new instrumental methods. A site study, with a focus on the polar regions, is performed to assess theoretical feasibility by simulating the downwelling clear-sky sub-millimetre spectrum from 30 mm (10 GHz) to 150 μm (2000 GHz) at six locations under annual mean, summer, winter, daytime, nighttime and low humidity conditions. Vertical profiles of temperature, pressure and 28 atmospheric gases are constructed by combining radiosonde, meteorological reanalysis, and atmospheric chemistry model data. The sensitivity of the simulated spectra to the choice of water vapour continuum model and spectroscopic line database is explored. For the atmospheric trace species hypobromous acid (HOBr), hydrogen bromide (HBr), perhydroxyl radical (HO2) and nitrous oxide (N2O) the emission lines producing the largest change in brightness temperature are identified. Signal strengths, centre frequencies, bandwidths, estimated minimum integration times and maximum receiver noise temperatures are determined for all cases. HOBr, HBr and HO2 produce brightness temperature peaks in the mK to K range, whereas the N2O peaks are in the K range. The optimal sub-millimetre remote sensing lines for the four species are shown to vary significantly between location and scenario, strengthening the case for future hyperspectral instruments that measure over a broad wavelength range. The techniques presented here provide a framework that can be applied to additional species of interest and taken forward to simulate retrievals and guide the design of future sub-millimetre instruments
The non-equilibrium response of a superconductor to pair-breaking radiation measured over a broad frequency band
We have measured the absorption of terahertz radiation in a BCS
superconductor over a broad range of frequencies from 200 GHz to 1.1 THz, using
a broadband antenna-lens system and a tantalum microwave resonator. From low
frequencies, the response of the resonator rises rapidly to a maximum at the
gap edge of the superconductor. From there on the response drops to half the
maximum response at twice the pair-breaking energy. At higher frequencies, the
response rises again due to trapping of pair-breaking phonons in the
superconductor. In practice this is the first measurement of the frequency
dependence of the quasiparticle creation efficiency due to pair-breaking in a
superconductor. The efficiency, calculated from the different non-equilibrium
quasiparticle distribution functions at each frequency, is in agreement with
the measurements.We would like to thank Jan Barkhof for help with the FTS calibration. This work was in part supported by ERC starting Grant Nos. ERC-2009-StG and 240602 TFPA. T. M. Klapwijk acknowledges financial support from the Ministry of Science and Education of Russia under Contract No. 14.B25.31.0007 and from the European Research Council Advanced Grant No. 339306 (METIQUM). P. J. de Visser acknowledges support from a Niels Stensen Fellowship.This is the author accepted manuscript. The final version is available from AIP via http://dx.doi.org/10.1063/1.492309
SWIPE: a bolometric polarimeter for the Large-Scale Polarization Explorer
The balloon-borne LSPE mission is optimized to measure the linear
polarization of the Cosmic Microwave Background at large angular scales. The
Short Wavelength Instrument for the Polarization Explorer (SWIPE) is composed
of 3 arrays of multi-mode bolometers cooled at 0.3K, with optical components
and filters cryogenically cooled below 4K to reduce the background on the
detectors. Polarimetry is achieved by means of large rotating half-wave plates
and wire-grid polarizers in front of the arrays. The polarization modulator is
the first component of the optical chain, reducing significantly the effect of
instrumental polarization. In SWIPE we trade angular resolution for
sensitivity. The diameter of the entrance pupil of the refractive telescope is
45 cm, while the field optics is optimized to collect tens of modes for each
detector, thus boosting the absorbed power. This approach results in a FWHM
resolution of 1.8, 1.5, 1.2 degrees at 95, 145, 245 GHz respectively. The
expected performance of the three channels is limited by photon noise,
resulting in a final sensitivity around 0.1-0.2 uK per beam, for a 13 days
survey covering 25% of the sky.Comment: In press. Copyright 2012 Society of Photo-Optical Instrumentation
Engineers. One print or electronic copy may be made for personal use only.
Systematic reproduction and distribution, duplication of any material in this
paper for a fee or for commercial purposes, or modification of the content of
the paper are prohibite
- …