654 research outputs found

    An evaluation of alternative techniques for estimating county population in a six-state area

    Get PDF
    County population statistics in Arkansas, Iowa, Kansas, Missouri, Nebraska, and Oklahoma for industry, government, and educatio

    Visual Impairment and Intracranial Hypertension: An Emerging Spaceflight Risk

    Get PDF
    What is the risk? Given that astronauts exposed to microgravity experience a cephalad fluid shift, and that both symptomatic and asymptomatic astronauts have exhibited optic nerve sheath edema on MRI, there is a high probability that all astronauts have some degree of increased intracranial pressure (ICP; intracranial hypertension), and that those susceptible (via eye architecture, anatomy, narrow optic disc) have a high likelihood of developing papilledema (optic disc edema, globe flattening), choroidal folds, and/or hyperopic shifts and that the degree of edema may determine long-term or permanent vision impairment or loss. Back to back panels on this topic have been developed to address this emerging risk. The first panel will focus on the 6 clinical cases with emphasis on ophthalmic findings and imaging techniques used pre-, in-, and post-flight. The second panel will discuss the operational mitigation and medical requirements, the potential role of CO2 on ISS, and the research approach being developed. In total these back to back panels will explore what is known about this risk, what has been done immediately to address it, and how an integrated research model is being developed

    Patient-reported outcomes measures and patient preferences for minimally invasive glaucoma surgical devices.

    Get PDF
    BackgroundMany therapeutic options are available to glaucoma patients. One recent therapeutic option is minimally invasive glaucoma surgical (MIGS) devices. It is unclear how patients view different treatments and which patient-reported outcomes would be most relevant in patients with mild to moderate glaucoma. We developed a questionnaire for patients eligible for MIGS devices and a patient preference study to examine the value patients place on certain outcomes associated with glaucoma and its therapies.ObjectivesTo summarize the progress to date.MethodsQuestionnaire development: We drafted the questionnaire items based on input from one physician and four patient focus groups, and a review of the literature. We tested item clarity with six cognitive interviews. These items were further refined. Patient preference study: We identified important benefit and risk outcomes qualitatively using semi-structured, one-on-one interviews with patients who were eligible for MIGS devices. We then prioritized these outcomes quantitatively using best-worst scaling methods.ResultsQuestionnaire testing: Three concepts were deemed relevant for the questionnaire: functional limitations, symptoms, and psychosocial factors. We will evaluate the reliability and validity of the 52-item draft questionnaire in an upcoming field test. Patient preference study: We identified 13 outcomes that participants perceived as important. Outcomes with the largest relative importance weights were "adequate IOP control" and "drive a car during the day."ConclusionsPatients have the potential to steer clinical research towards outcomes that are important to them. Incorporating patients' perspectives into the MIGS device development and evaluation process may expedite innovation and availability of these devices

    Do Astronauts have a Higher Rate of Orthopedic Shoulder Conditions than a Cohort of Working Professionals?

    Get PDF
    Occupational surveillance of astronaut shoulder injuries began with operational concerns at the Neutral Buoyancy Laboratory (NBL) during Extra Vehicular Activity (EVA) training. NASA has implemented several occupational health initiatives during the past 20 years to decrease the number and severity of injuries, but the individual success rate is unknown. Orthopedic shoulder injury and surgery rates were calculated, but classifying the rates as normal, high or low was highly dependent on the comparison group. The purpose of this study was to identify a population of working professionals and compare orthopedic shoulder consultation and surgery rates

    The Regional Background of Oklahoma's People

    Get PDF

    Variations in Income and Levels of Living of Oklahoma People

    Get PDF

    Do Astronauts Havbe a Higher Rate of Orthopedic Shoulder Conditions Than a Cohort of Working Professionals

    Get PDF
    Occupational surveillance of astronaut shoulder injuries began with operational concerns at the Neutral Buoyancy Laboratory (NBL) during Extra Vehicular Activity (EVA) training. Orthopedic shoulder injury and surgery rates were calculated [1], but classifying the rates as normal, high or low was highly dependent on the comparison group. Thus, the purpose of this study was to identify a population of working professionals and compare orthopedic shoulder consultation and surgery rates

    Orion Portable Fire Extinguisher Performance Testing Against a Laptop Lithium-Ion Battery Stored-Energy Fire-Method, Magnesium Fires, and Combustion By-Product Toxicity

    Get PDF
    As part of the qualification of the International Space Station (ISS) fine water mist portable fire extinguisher (PFE), several test methods were developed to determine firefighting capability against stored-energy sources. The most challenging of these devised stored-energy fire test methods proved to be the Lithium-ion (Li-ion) battery fire test scenario. The Orion crew capsule will utilize a different PFE technology from ISS (water spray rather than water mist), which spurred the need for the same type of evaluation focused on the sources of stored energy slated for use on Orion. Laptops were identified as a realistic source for stored-energy fires, requiring a modified Li-ion battery fire test scenario. In addition to open test cell (ambient oxygen concentration) testing to evaluate new proposed PFE performance, sealed chamber (20.9% and elevated oxygen concentration) testing was also performed. Chamber testing included combustion product sampling at various fire progression points for analysis and application to Orion emergency equipment design and response planning. The PFE stored-energy fire test methodology was modified and testing performed. Initial tests indicated ignition of the laptop magnesium laptop cases was possible. Additional tests were performed to characterize the laptop magnesium case fire behavior in various configurations. The new water spray PFE technology proved effective in extinguishing laptop stored-energy fires, and much was learned in the way these types of fires progressed. Findings indicate potential laptop magnesium case ignition mitigation strategies need to be further investigated

    Crowdsourced Mapping in Crisis Zones: Collaboration, Organisation and Impact

    Get PDF
    Crowdsourced mapping has become an integral part of humanitarian response, with high profile deployments of platforms following the Haiti and Nepal earthquakes, and the multiple projects initiated during the Ebola outbreak in North West Africa in 2014, being prominent examples. There have also been hundreds of deployments of crowdsourced mapping projects across the globe, that did not have a high profile. This paper, through an analysis of 51 mapping deployments between 2010–2016, complimented with expert interviews, seeks to explore the organisational structures that create the conditions for effective mapping actions, and the relationship between the commissioning body, often a Non-Governmental Organisation (NGO) and the volunteers who regularly make up the team charged with producing the map. The research suggests that there are three distinct areas that need to be improved in-order to provide appropriate assistance through mapping in humanitarian crisis; regionalise; prepare; and research. The paper concludes, based on the case studies, how each of these areas can be handled more effectively, concluding that failure to implement one area sufficiently can lead to overall project failure
    corecore