25 research outputs found

    Fragmentation of 120 and 200 MeV/u 4^4He in water

    Get PDF

    A compact Time-Of-Flight detector for space applications: The LIDAL system

    Get PDF
    Abstract LIDAL (Light Ion Detector for ALTEA system) is a compact detector designed to upgrade ALTEA (Anomalous Long Term Effects on Astronauts) silicon detector apparatus, in order to study in detail the low-Z part of ions spectrum inside the International Space Station (ISS) and to enhance the Particle Identification (PID) capability of the system. The new detector is designed to trigger ALTEA and to perform Time-Of-Flight measurements. It is based on plastic scintillators for fast timing applications read by Photo-Multiplier-Tubes (PMTs). A custom Front End Electronics (FEE) has been designed to reach time resolutions less than 100 ps ( σ ) for protons. A LIDAL prototype has been developed at the University of Rome Tor Vergata to test the timing performance of the scintillators, the PMTs and of the custom FEE using the proton beam line at the TIFPA (Trento Institute for Fundamentals Physics Applications) center in Trento, Italy. The results of these tests are reported and discussed. They have also been used for a preliminary evaluation of the Particle Identification (PID) capability of the final LIDAL-ALTEA detector system in response to the ions spectra expected on-board the ISS

    Performance of the ToF detectors in the foot experiment

    Get PDF
    The FOOT (FragmentatiOn Of Target) experiment aims to deter- mine the fragmentation cross-sections of nuclei of interest for particle therapy and radioprotection in space. The apparatus is composed of several detectors that allow fragment identification in terms of charge, mass, energy and direction. The frag- ment time of flight (ToF) along a lever arm of ∼2 m is used for particle ID, requiring a resolution below 100ps to achieve a sufficient resolution in the fragment atomic mass identification. The timing performance of the ToF system evaluated with 12C and 16O beams is reviewed in this contribution

    A Geant4 based simulation platform of the HollandPTC R&D proton beamline for radiobiological studies

    No full text
    A Geant4 based simulation platform of the Holland Proton Therapy Centre (HollandPTC, Netherlands) R&D beamline (G4HPTC-R&D) was developed to enable the planning, optimisation and advanced dosimetry for radiobiological studies. It implemented a six parameter non-symmetrical Gaussian pencil beam surrogate model to simulate the R&D beamline in both a pencil beam and passively scattered field configuration. Three different experimental proton datasets (70 MeV, 150 MeV, and 240 MeV) of the pencil beam envelope evolution in free air and depth-dose profiles in water were used to develop a set of individual parameter surrogate functions to enable the modelling of the non-symmetrical Gaussian pencil beam properties with only the ProBeam isochronous cyclotron mean extraction proton energy as input. This refined beam model was then benchmarked with respect to three independent experimental datasets of the R&D beamline operating in both a pencil beam configuration at 120 and 200 MeV, and passively scattered field configuration at 150 MeV. It was shown that the G4HPTC-R&D simulation platform can reproduce the pencil beam envelope evolution in free air and depth-dose profiles to within an accuracy on the order of ±5% for all tested energies, and that it was able to reproduce the 150 MeV passively scattered field to the specifications need for clinical and radiobiological applications.RST/Medical Physics & TechnologyRST/Reactor Physics and Nuclear Material

    <i>Ex vivo</i> radiation sensitivity assessment for individual head and neck cancer patients using deep learning-based automated nuclei and DNA damage foci detection

    Get PDF
    Introduction: Tumor biopsy tissue response to ex vivo irradiation is potentially an interesting biomarker for in vivo tumor response, therefore, for treatment personalization. Tumor response ex vivo can be characterized by DNA damage response, expressed by the large-scale presence of DNA damage foci in tumor nuclei. Currently, characterizing tumor nuclei and DNA damage foci is a manual process that takes hours per patient and is subjective to inter-observer variability, which is not feasible in for clinical decision making. Therefore, our goal was to develop a method to automatically segment nuclei and DNA damage foci in tumor tissue samples treated with radiation ex vivo to characterize the DNA damage response, as potential biomarker for in vivo radio-sensitivity. Methods: Oral cavity tumor tissue of 21 patients was irradiated ex vivo (5 or 0 Gy), fixated 2 h post-radiation, and used to develop our method for automated nuclei and 53BP1 foci segmentation. The segmentation model used both deep learning and conventional image-analysis techniques. The training (22 %), validation (22 %), and test set (56 %) consisted of thousands of manually segmented nuclei and foci. The segmentations and number of foci per nucleus in the test set were compared to their ground truths. Results: The automatic nuclei and foci segmentations were highly accurate (Dice = 0.901 and Dice = 0.749, respectively). An excellent correlation (R2 = 0.802) was observed for the foci per nucleus that outperformed reported inter-observation variation. The analysis took ∼ 8 s per image. Conclusion: This model can replace manual foci analysis for ex vivo irradiation of head-and-neck squamous cell carcinoma tissue, reduces the image-analysis time from hours to minutes, avoids the problem of inter-observer variability, enables assessment of multiple images or conditions, and provides additional information about the foci size. Thereby, it allows for reliable and rapid ex vivo radio-sensitivity assessment, as potential biomarker for response in vivo and treatment personalization.</p

    A hybrid multi-particle approach to range assessment-based treatment verification in particle therapy

    No full text
    Particle therapy (PT) used for cancer treatment can spare healthy tissue and reduce treatment toxicity. However, full exploitation of the dosimetric advantages of PT is not yet possible due to range uncertainties, warranting development of range-monitoring techniques. This study proposes a novel range-monitoring technique introducing the yet unexplored concept of simultaneous detection and imaging of fast neutrons and prompt-gamma rays produced in beam-tissue interactions. A quasi-monolithic organic detector array is proposed, and its feasibility for detecting range shifts in the context of proton therapy is explored through Monte Carlo simulations of realistic patient models and detector resolution effects. The results indicate that range shifts of 1mm can be detected at relatively low proton intensities (22.30 (13) × 10 7 protons/spot) when spatial information obtained through imaging of both particle species are used simultaneously. This study lays the foundation for multi-particle detection and imaging systems in the context of range verification in PT.</p

    Fragmentation of 120 and 200 MeV u-14He ions in water and PMMA targets

    No full text
    Recently, the use of 4He particles in cancer radiotherapy has been reconsidered as they potentially represent a good compromise between protons and 12C ions. The first step to achieve this goal is the development of a dedicated treatment planning system, for which basic physics information such as the characterization of the beam lateral scattering and fragmentation cross sections are required. In the present work, the attenuation of 4He primary particles and the build-up of secondary charged fragments at various depths in water and polymethyl methacrylate were investigated experimentally for 120 and 200 MeV u-1 beams delivered by the synchrotron at the Heidelberg Ion-Beam Therapy Center, Heidelberg. Species and isotope identification was accomplished combining energy loss and time-of-flight measurements. Differential yields and energy spectra of all fragments types were recorded between 0° and 20° with respect to the primary beam direction

    Fragmentation of 120 and 200 MeV u −1 4 He ions in water and PMMA targets

    Get PDF
    Recently, the use of 4 He particles in cancer radiotherapy has been reconsidered as they potentially represent a good compromise between protons and 12C ions. The first step to achieve this goal is the development of a dedicated treatment planning system, for which basic physics information such as the characterization of the beam lateral scattering and fragmentation cross sections are required. In the present work, the attenuation of 4 He primary particles and the build-up of secondary charged fragments at various depths in water and polymethyl methacrylate were investigated experimentally for 120 and 200 MeV u−1 beams delivered by the synchrotron at the Heidelberg Ion-Beam Therapy Center, Heidelberg. Species and isotope identification was accomplished combining energy loss and time-of-flight measurements. Differential yields and energy spectra of all fragments types were recorded between 0° and 20° with respect to the primary beam directio

    A hybrid multi-particle approach to range assessment-based treatment verification in particle therapy

    No full text
    Particle therapy (PT) used for cancer treatment can spare healthy tissue and reduce treatment toxicity. However, full exploitation of the dosimetric advantages of PT is not yet possible due to range uncertainties, warranting development of range-monitoring techniques. This study proposes a novel range-monitoring technique introducing the yet unexplored concept of simultaneous detection and imaging of fast neutrons and prompt-gamma rays produced in beam-tissue interactions. A quasi-monolithic organic detector array is proposed, and its feasibility for detecting range shifts in the context of proton therapy is explored through Monte Carlo simulations of realistic patient models and detector resolution effects. The results indicate that range shifts of 1mm can be detected at relatively low proton intensities (22.30 (13) × 10 7 protons/spot) when spatial information obtained through imaging of both particle species are used simultaneously. This study lays the foundation for multi-particle detection and imaging systems in the context of range verification in PT. © 2023, The Author(s)
    corecore