329 research outputs found

    Initial experience of a large, self-expanding, and fully recapturable transcatheter aortic valve: The UK & Ireland Implanters' registry.

    Get PDF
    OBJECTIVES: The UK & Ireland Implanters' registry is a multicenter registry which reports on real-world experience with novel transcatheter heart valves. BACKGROUND: The 34 mm Evolut R transcatheter aortic valve is a self-expanding and fully recapturable transcatheter aortic valve, designed to treat patients with a large aortic annulus. METHODS: Between January 2017 and April 2018, clinical, procedural and 30-day outcome data were prospectively collected from all patients receiving the 34 mm Evolut R valve across 17 participating centers in the United Kingdom and Ireland. The primary efficacy outcome was the Valve Academic Research Consortium-2(VARC-2)-defined endpoint of device success. The primary safety outcome was the VARC-2-defined composite endpoint of early safety at 30 days. RESULTS: A total of 217 patients underwent attempted implant. Mean age was 79.5 ± 8.8 years and Society of Thoracic Surgeons Predicted Risk of Mortality Score 5.2% ± 3.4%. Iliofemoral access was used in 91.2% of patients. Device success was 79.7%. Mean gradient was 7.0 ± 4.6 mmHg and effective orifice area 2.0 ± 0.6 cm2 . Paravalvular regurgitation was more than mild in 7.2%. A new permanent pacemaker was implanted in 15.7%. Early safety was demonstrated in 91.2%. At 30 days, all-cause mortality was 3.2%, stroke 3.7%, and major vascular complication 2.3%. CONCLUSIONS: Real-world experience of the 34 mm Evolut R transcatheter aortic valve demonstrated acceptable procedural success, safety, valve function, and incidence of new permanent pacemaker implantation

    Rationale and design of the prevail global trial program evaluating the prevail drug-coated balloon in patients with in-stent restenosis and de novo small vessel disease

    Get PDF
    \ua9 2025 The AuthorsBackground and Rationale: In-stent restenosis (ISR) remains the leading cause of treatment failure following percutaneous coronary intervention (PCI) with contemporary drug-eluting stents. Especially in small caliber coronary arteries, restenosis is common following PCI and represents a treatment challenge. Drug-coated balloons (DCB) are an attractive alternative to stents for treatment of both ISR and small vessel disease. The safety and efficacy of the Prevail DCB will be assessed for (1) the treatment of ISR and (2) de novo lesions in small vessels. Trial Design: Prevail Global is a prospective, international, dual cohort clinical study enrolling (1) patients undergoing PCI for ISR in a randomized controlled trial (1:1) design comparing the Prevail DCB versus an FDA-approved DCB (AgentTM, Boston Scientific Corporation, Natick MA), and (2) patients with de novo small vessel disease undergoing PCI with the Prevail DCB as part of a single-arm study compared with a historical control. The primary endpoint is target lesion failure, defined as a composite of cardiac death, target vessel myocardial infarction, or clinically-driven target lesion revascularization at 12 months post procedure. Patient follow-up is planned for 1 month, 6 months, and yearly through 5 years. Enrollment is expected to start in early 2025. Conclusions: The Prevail Global study will directly assess the safety and efficacy of the Prevail DCB for the treatment of ISR and de novo small vessel lesions. Trial Registration: Prevail Global, NCT06535854, is registered at https://clinicaltrials.gov/study/NCT06535854

    Intestinal carriage of Staphylococcus aureus: How does its frequency compare with that of nasal carriage and what is its clinical impact?

    Get PDF
    The bacterial species Staphylococcus aureus, including its methicillin-resistant variant (MRSA), finds its primary ecological niche in the human nose, but is also able to colonize the intestines and the perineal region. Intestinal carriage has not been widely investigated despite its potential clinical impact. This review summarizes literature on the topic and sketches the current state of affairs from a microbiological and infectious diseases' perspective. Major findings are that the average reported detection rate of intestinal carriage in healthy individuals and patients is 20% for S. aureus and 9% for MRSA, which is approximately half of that for nasal carriage. Nasal carriage seems to predispose to intestinal carriage, but sole intestinal carriage occurs relatively frequently and is observed in 1 out of 3 intestinal carriers, which provides a rationale to include intestinal screening for surveillance or in outbreak settings. Colonization of the intestinal tract with S. aureus at a young age occurs at a high frequency and may affect the host's immune system. The frequency of intestinal carriage is generally underestimated and may significantly contribute to bacterial dissemination and subsequent risk of infections. Whether intestinal rather than nasal S. aureus carriage is a primary predictor for infections is still ill-defined

    Rationale and design of a randomized clinical trial comparing safety and efficacy of myval transcatheter heart valve versus contemporary transcatheter heart valves in patients with severe symptomatic aortic valve stenosis: The LANDMARK trial

    Get PDF
    BACKGROUND: The recent approval of transcatheter aortic valve replacement (TAVR) in patients with low operative risk has paved the way for the introduction of novel and potentially improved technologies. The safety and efficacy of these novel technologies should be investigated in randomized control trials against the contemporary TAVR devices. The objective of the LANDMARK trial is to compare the balloon-expandable Myval transcatheter heart valve (THV) series with contemporary THV (SAPIEN THV and Evolut THV series) series in patients with severe symptomatic native aortic stenosis. METHODS/DESIGN: The LANDMARK trial (ClinicalTrials.govNCT04275726, EudraCT number 2020-000,137-40) is a prospective, randomized, multinational, multicenter, open-label, and noninferiority trial of approximately 768 patients treated with TAVR via the transfemoral approach. Patients will be allocated in a 1:1 randomization to Myval THV series (n = 384) or to contemporary THV (n = 384) (either of SAPIEN THV or Evolut THV series). The primary combined safety and efficacy endpoint is a composite of all-cause mortality, all stroke (disabling and nondisabling), bleeding (life-threatening or disabling), acute kidney injury (stage 2 or 3), major vascular complications, prosthetic valve regurgitation (moderate or severe), and conduction system disturbances (requiring new permanent pacemaker implantation), according to the Valve Academic Research Consortium-2 criteria at 30-day follow-up. All patients will have follow-up to 10 years following TAVR. SUMMARY: The LANDMARK trial is the first randomized head-to-head trial comparing Myval THV series to commercially available THVs in patients indicated for TAVR. We review prior data on head-to-head comparisons of TAVR devices and describe the rationale and design of the LANDMARK trial

    Clinical Predictors for Procedural Stroke and Implications for Embolic Protection Devices during TAVR: Results from the Multicenter Transcatheter Aortic Valve Replacement In-Hospital Stroke (TASK) Study

    Get PDF
    \ua9 2022 by the authors. Licensee MDPI, Basel, Switzerland. Background: Data to support the routine use of embolic protection devices for stroke prevention during transcatheter aortic valve replacement (TAVR) are controversial. Identifying patients at high risk for peri-procedural cerebrovascular events may facilitate effective patient selection for embolic protection devices during TAVR. Aim: To generate a risk score model for stratifying TAVR patients according to peri-procedural cerebrovascular events risk. Methods and results: A total of 8779 TAVR patients from 12 centers worldwide were included. Peri-procedural cerebrovascular events were defined as an ischemic stroke or a transient ischemic attack occurring ≤24 h from TAVR. The peri-procedural cerebrovascular events rate was 1.4% (n = 127), which was independently associated with 1-year mortality (hazards ratio (HR) 1.78, 95% confidence interval (CI) 1.06–2.98, p < 0.028). The TASK risk score parameters were history of stroke, use of a non-balloon expandable valve, chronic kidney disease, and peripheral vascular disease, and each parameter was assigned one point. Each one-point increment was associated with a significant increase in peri-procedural cerebrovascular events risk (OR 1.96, 95% CI 1.56–2.45, p < 0.001). The TASK score was dichotomized into very-low, low, intermediate, and high (0, 1, 2, 3–4 points, respectively). The high-risk TASK score group (OR 5.4, 95% CI 2.06–14.16, p = 0.001) was associated with a significantly higher risk of peri-procedural cerebrovascular events compared with the low TASK score group. Conclusions: The proposed novel TASK risk score may assist in the pre-procedural risk stratification of TAVR patients for peri-procedural cerebrovascular events

    Empiric Antibiotic Therapy for Staphylococcus aureus Bacteremia May Not Reduce In-Hospital Mortality: A Retrospective Cohort Study

    Get PDF
    Appropriate empiric therapy, antibiotic therapy with in vitro activity to the infecting organism given prior to confirmed culture results, may improve Staphylococcus aureus outcomes. We aimed to measure the clinical impact of appropriate empiric antibiotic therapy on mortality, while statistically adjusting for comorbidities, severity of illness and presence of virulence factors in the infecting strain.We conducted a retrospective cohort study of adult patients admitted to a tertiary-care facility from January 1, 2003 to June 30, 2007, who had S. aureus bacteremia. Time to appropriate therapy was measured from blood culture collection to the receipt of antibiotics with in vitro activity to the infecting organism. Cox proportional hazard models were used to measure the association between receipt of appropriate empiric therapy and in-hospital mortality, statistically adjusting for patient and pathogen characteristics.Among 814 admissions, 537 (66%) received appropriate empiric therapy. Those who received appropriate empiric therapy had a higher hazard of 30-day in-hospital mortality (Hazard Ratio (HR): 1.52; 95% confidence interval (CI): 0.99, 2.34). A longer time to appropriate therapy was protective against mortality (HR: 0.79; 95% CI: 0.60, 1.03) except among the healthiest quartile of patients (HR: 1.44; 95% CI: 0.66, 3.15).Appropriate empiric therapy was not associated with decreased mortality in patients with S. aureus bacteremia except in the least ill patients. Initial broad antibiotic selection may not be widely beneficial

    Safety and Efficacy of Myval Implantation in Patients with Severe Bicuspid Aortic Valve Stenosis-A Multicenter Real-World Experience.

    Get PDF
    Bicuspid aortic valve (BAV) is the most common valvular congenital anomaly and is apparent in nearly 50% of candidates for AV replacement. While transcatheter aortic valve implantation (TAVI) is a recommended treatment for patients with symptomatic severe aortic stenosis (AS) at all surgical risk levels, experience with TAVI in severe bicuspid AS is limited. TAVI in BAV is still a challenge due to its association with multiple and complex anatomical considerations. A retrospective study has been conducted to investigate TAVI's procedural and 30-day outcomes using the Myval transcatheter heart valve (THV) (Meril Life Sciences Pvt. Ltd. Vapi, Gujarat, India) in patients with severe bicuspid AS. Data were collected on 68 patients with severe bicuspid AS who underwent TAVI with the Myval THV. Baseline characteristics, procedural, 30-day echocardiographic and clinical outcomes were collected. The mean age and STS PROM score were 72.6 ± 9.4 and 3.54 ± 2.1. Procedures were performed via the transfemoral route in 98.5%. Major vascular complications (1.5%) and life-threatening bleeding (1.5%) occurred infrequently. No patient had coronary obstruction, second valve implantation or conversion to surgery. On 30-day echocardiography, the mean transvalvular gradient and effective orifice area were 9.8 ± 4.5 mmHg and 1.8 ± 0.4 cm2, respectively. None/trace aortic regurgitation occurred in 76.5%, mild AR in 20.5% and moderate AR in 3%. The permanent pacemaker implantation rate was 8.5% and 30-day all-cause death occurred in 3.0% of cases. TAVI with the Myval THV in selected BAV anatomy is associated with favorable short-term hemodynamic and clinical outcomes
    corecore