79 research outputs found

    Cost-effective therapy remission assessment in lymphoma patients using 2-[fluorine-18]fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography: is an end of treatment exam necessary in all patients?

    Get PDF
    Background: The aim of this study was to evaluate the necessity of 2-[fluorine-18]fluoro-2-deoxy-D-glucose-positron emission tomography/computed tomography (FDG-PET/CT) after end of treatment in lymphoma patients who had an interim FDG-PET/CT. Patients and methods: In 38 patients with Hodgkin's disease (HD) and 30 patients with non-Hodgkin's lymphoma (NHL) interim PET/CT (intPET) after two to four cycles of chemotherapy and PET/CT after completion of first-line treatment (endPET) were carried out. Cost reduction was retrospectively calculated for the potentially superfluous endPET examinations. Results: In 31 (82%) HD patients, intPET demonstrated complete remission (CR) which was still present on endPET. The remaining seven HD patients (18%) had partial remission (PR) on intPET. For NHL, 22 (73%) patients had CR on intPET analysis which was still present on endPET. In the remaining eight NHL patients, intPET revealed PR in seven and stable disease in one patient. None of all intPET complete responders progressed until the end of therapy. Thus, of the 196 PET/CT's carried out in our study population, 53 endPET's (27.0%) were carried out in interim complete responders. Conclusion: End-treatment PET/CT is unnecessary if intPET shows CR and the clinical course is uncomplicated. An imaging cost reduction of 27% in our study population could have been achieved by omitting end of treatment FDG-PET/CT in interim complete responder

    Asteroids' physical models from combined dense and sparse photometry and scaling of the YORP effect by the observed obliquity distribution

    Full text link
    The larger number of models of asteroid shapes and their rotational states derived by the lightcurve inversion give us better insight into both the nature of individual objects and the whole asteroid population. With a larger statistical sample we can study the physical properties of asteroid populations, such as main-belt asteroids or individual asteroid families, in more detail. Shape models can also be used in combination with other types of observational data (IR, adaptive optics images, stellar occultations), e.g., to determine sizes and thermal properties. We use all available photometric data of asteroids to derive their physical models by the lightcurve inversion method and compare the observed pole latitude distributions of all asteroids with known convex shape models with the simulated pole latitude distributions. We used classical dense photometric lightcurves from several sources and sparse-in-time photometry from the U.S. Naval Observatory in Flagstaff, Catalina Sky Survey, and La Palma surveys (IAU codes 689, 703, 950) in the lightcurve inversion method to determine asteroid convex models and their rotational states. We also extended a simple dynamical model for the spin evolution of asteroids used in our previous paper. We present 119 new asteroid models derived from combined dense and sparse-in-time photometry. We discuss the reliability of asteroid shape models derived only from Catalina Sky Survey data (IAU code 703) and present 20 such models. By using different values for a scaling parameter cYORP (corresponds to the magnitude of the YORP momentum) in the dynamical model for the spin evolution and by comparing synthetics and observed pole-latitude distributions, we were able to constrain the typical values of the cYORP parameter as between 0.05 and 0.6.Comment: Accepted for publication in A&A, January 15, 201

    The Hybrid SPECT/CT as an Additional Lymphatic Mapping Tool in Patients with Breast Cancer

    Get PDF
    Background Conventional lymphoscintigraphy does not always define the exact anatomic location of a sentinel node. The lymphatic drainage pattern may be unusual or may not be shown at all. The recently introduced hybrid SPECT/CT imaging could help overcome these difficulties. SPECT is a tomographic version of conventional lymphoscintigraphy and the images have better contrast and resolution. When fused with the anatomical details provided by CT into one image, a meaningful surgical ‘‘roadmap’’ can be created. So far, there is little literature on the use of hybrid SPECT/CT in lymphatic mapping in patients with breast cancer. The purpose of this review was to report on these publications, including our own experience, focusing on patient selection, SPECT/CT settings, anatomic localization, and the detection of additional sentinel nodes. Methods The majority of investigators did not formulate indications for additional SPECT/CT after conventional imaging but scanned all patients eligible for sentinel node biopsy. The SPECT/CT settings used in the studies of this review were mostly similar, but the methods used for conventional imaging were more variable. Results All studies demonstrated an improved anatomical localization by performing additional SPECT/CT; sentinel nodes outside the axilla or nodes close to the injection sit

    Awareness and current knowledge of breast cancer

    Full text link

    Low-dose unenhanced CT for IV contrast bolus timing: is it reliable to assess hepatic steatosis?

    Full text link
    RATIONALE AND OBJECTIVES: To determine whether an unenhanced low-dose image acquired during automated contrast bolus timing can be used to assess hepatic steatosis. MATERIALS AND METHODS: Fifty subjects (29 male, 21 female; 26-92 years; mean body mass index (BMI; 26.9) with abdominal multiphasic computed tomography were included. Abdominal diameters and circumferences were derived from anteroposterior and lateral scout radiographs. Hepatic attenuation (HA) was measured on unenhanced low-dose images (120 kV; 40 mA; 0.5 seconds' rotation time) and corresponding unenhanced standard-dose images (120 kV, z-axis automatic tube current modulation, noise index 11.5). Noise estimates were measured in surrounding air. Pearson correlation was calculated between abdominal circumference and BMI. Mean HA assessed on low-dose images and standard-dose images was compared using a paired Student's t-test and Bland Altman plots. RESULTS: Abdominal circumference (mean, 142.8cm) correlated well with BMI (r = 0.83). No significant difference was found for HA on low-dose images (mean +57.7 HU) compared to HA on standard-dose images (+56.0 HU) (P = .077). Image noise (+11.5 HU) was significantly higher on low-dose images compared to image noise (+8.1 HU) on standard-dose images (P < .05). For HA mean difference comparing low- and standard-dose images was -1.7 HU (limits of agreement: -14.6, 11.2). CONCLUSION: In all subjects, hepatic attenuation can be correctly assessed on unenhanced low-dose images

    Fragmentation of transient water anions following low-energy electron capture by H2O/D2O

    No full text
    Dissociative electron attachment (DEA) to water in the gaseous phase has been studied using two different crossed electron–molecule beam apparatus. Ion yields for the formation of the three fragments H-, O- and OH- were measured as a function of the incident electron energy. The kinetic energies of the fragment ions were measured and compared with the values derived from ab initio calculations to provide information on the energy partitioning in the fragmentation process. Isotope and temperature effects on the attachment process are discussed and the production of OH- via DEA is confirmed

    Contrast enhanced liver MRI in patients with primary sclerosing cholangitis: Inverse appearance of focal confluent fibrosis on delayed phase MR images with hepatocyte specific versus extracellular gadolinium based contrast agents

    Full text link
    RATIONALE AND OBJECTIVES: To assess the enhancement pattern of focal confluent fibrosis (FCF) on contrast-enhanced hepatic magnetic resonance imaging (MRI) using hepatocyte-specific (Gd-EOB-DTPA) and extracellular (ECA) gadolinium-based contrast agents in patients with primary sclerosing cholangitis (PSC). MATERIALS AND METHODS: After institutional review board approval, 10 patients with PSC (6 male, 4 female; 33-61 years) with 13 FCF were included in this retrospective study. All patients had a Gd-EOB-DTPA-enhanced liver MRI exam, and a comparison ECA-enhanced MRI. On each T1-weighted dynamic dataset, the signal intensity (SI) of FCF and the surrounding liver as well as the paraspinal muscle (M) were measured. In the Gd-EOB-DTPA group, hepatocyte phase images were also included. SI FCF/SI M, SI liver/SI M, and [(SI liver - SI FCF)/SI liver] were compared between the different contrast agents for each dynamic phase using the paired Student's t-test. RESULTS: There was no significant difference in SI FCF/SI M in all imaging phases. SI liver/SI M was significantly higher for the Gd-EOB-DTPA group in the delayed phase (P < .001), whereas there was no significant difference in all other imaging phases. In the Gd-EOB-DTPA group, mean [(SI liver - SI FCF)/SI liver] were as follows (values for ECA group in parentheses): unenhanced phase: 0.26 (0.26); arterial phase: 0.01 (-0.31); portal venous phase (PVP): -0.05 (-0.26); delayed phase (DP): 0.14 (-0.54); and hepatocyte phase: 0.26. Differences were significant for the DP (P < .001). CONCLUSIONS: On delayed phase MR images the FCF-to-liver contrast is reversed with the lesions appearing hyperintense on ECA enhanced images and hypointense on Gd-EOB-DTPA-enhanced images

    Characterization of focal bone lesions in the axial skeleton: performance of planar bone scintigraphy compared with SPECT and SPECT fused with CT

    Full text link
    OBJECTIVE: The purpose of this study was to evaluate the diagnostic performance of planar 99mTc methylene diphosphonate bone scintigraphy compared with SPECT and SPECT fused with CT in patients with focal bone lesions of the axial skeleton. SUBJECTS AND METHODS: Thirty-seven patients with 42 focal lesions of the axial skeleton were included in this prospective study. All patients underwent planar scintigraphy, SPECT through the focal lesions, and SPECT-guided CT. SPECT and CT images then were fused digitally. The three types of images were evaluated separately from one another by two experienced reviewers working to consensus. Visibility of the lesions, diagnostic performance, and certainty in diagnosis were evaluated. Performance for specific diagnoses also was evaluated. Histologic, MRI, and clinical follow-up findings were used as the reference standard. RESULTS: Visibility of the lesions was significantly better with SPECT than with planar scintigraphy (p < 0.0001). Sensitivity and specificity for differentiation of benign and malignant bone lesions were 82% and 94% for planar scintigraphy, 91% and 94% for SPECT, and 100% and 100% for SPECT fused with CT. Differences between the three methods of differentiating benign and malignant lesions did not reach statistical significance. Certainty in diagnosis was significantly higher for SPECT fused with CT than for planar scintigraphy (p = 0.004) and SPECT (p = 0.004). A specific diagnosis was made with planar scintigraphy in 64% of cases, with SPECT in 86%, and with SPECT fused with CT in all cases. CONCLUSION: Planar scintigraphy may suffice for differentiating benign and malignant lesions of the axial skeleton, but SPECT fused with CT significantly increases certainty in diagnosis and is the best tool for making a specific diagnosis
    • …
    corecore