212 research outputs found

    Renormalization of the charged scalar field in curved space

    Full text link
    The DeWitt-Schwinger proper time point-splitting procedure is applied to a massive complex scalar field with arbitrary curvature coupling interacting with a classical electromagnetic field in a general curved spacetime. The scalar field current is found to have a linear divergence. The presence of the external background gauge field is found to modify the stress-energy tensor results of Christensen for the neutral scalar field by adding terms of the form (eF)2(eF)^2 to the logarithmic counterterms. These results are shown to be expected from an analysis of the degree of divergence of scalar quantum electrodynamics.Comment: 24 pages REVTe

    Internal Structure of Einstein-Yang-Mills Black Holes

    Get PDF
    It is shown that a generic black hole solution of the SU(2) Einstein-Yang-Mills equations develops a new type of an infinitely oscillating behavior near the singularity. Only for certain discrete values of the event horizon radius exceptional solutions exist, possessing an inner structure of the Schwarzschild or Reissner-Nordstrom type.Comment: 4.5 LaTeX pages, 8 eps figures, uses RevTeX, boxedeps.tex. 4 more typos fixed, a footnote adde

    The Palomar Testbed Interferometer

    Get PDF
    The Palomar Testbed Interferometer (PTI) is a long-baseline infrared interferometer located at Palomar Observatory, California. It was built as a testbed for interferometric techniques applicable to the Keck Interferometer. First fringes were obtained in July 1995. PTI implements a dual-star architecture, tracking two stars simultaneously for phase referencing and narrow-angle astrometry. The three fixed 40-cm apertures can be combined pair-wise to provide baselines to 110 m. The interferometer actively tracks the white-light fringe using an array detector at 2.2 um and active delay lines with a range of +/- 38 m. Laser metrology of the delay lines allows for servo control, and laser metrology of the complete optical path enables narrow-angle astrometric measurements. The instrument is highly automated, using a multiprocessing computer system for instrument control and sequencing.Comment: ApJ in Press (Jan 99) Fig 1 available from http://huey.jpl.nasa.gov/~bode/ptiPicture.html, revised duging copy edi

    A report on the piloting of a novel computer-based medical case simulation for teaching and formative assessment of diagnostic laboratory testing

    Get PDF
    Objectives: Insufficient attention has been given to how information from computer-based clinical case simulations is presented, collected, and scored. Research is needed on how best to design such simulations to acquire valid performance assessment data that can act as useful feedback for educational applications. This report describes a study of a new simulation format with design features aimed at improving both its formative assessment feedback and educational function. Methods: Case simulation software (LabCAPS) was developed to target a highly focused and well-defined measurement goal with a response format that allowed objective scoring. Data from an eight-case computer-based performance assessment administered in a pilot study to 13 second-year medical students was analyzed using classical test theory and generalizability analysis. In addition, a similar analysis was conducted on an administration in a less controlled setting, but to a much large sample (n=143), within a clinical course that utilized two random case subsets from a library of 18 cases. Results: Classical test theory case-level item analysis of the pilot assessment yielded an average case discrimination of 0.37, and all eight cases were positively discriminating (range=0.11–0.56). Classical test theory coefficient alpha and the decision study showed the eight-case performance assessment to have an observed reliability of σ=G=0.70. The decision study further demonstrated that a G=0.80 could be attained with approximately 3 h and 15 min of testing. The less-controlled educational application within a large medical class produced a somewhat lower reliability for eight cases (G=0.53). Students gave high ratings to the logic of the simulation interface, its educational value, and to the fidelity of the tasks. Conclusions: LabCAPS software shows the potential to provide formative assessment of medical students’ skill at diagnostic test ordering and to provide valid feedback to learners. The perceived fidelity of the performance tasks and the statistical reliability findings support the validity of using the automated scores for formative assessment and learning. LabCAPS cases appear well designed for use as a scored assignment, for stimulating discussions in small group educational settings, for self-assessment, and for independent learning. Extension of the more highly controlled pilot assessment study with a larger sample will be needed to confirm its reliability in other assessment applications

    Response Characterization of Electroactive Polymers as Mechanical Sensors

    Full text link

    Fundamental Physics with the Laser Astrometric Test Of Relativity

    Full text link
    The Laser Astrometric Test Of Relativity (LATOR) is a joint European-U.S. Michelson-Morley-type experiment designed to test the pure tensor metric nature of gravitation - a fundamental postulate of Einstein's theory of general relativity. By using a combination of independent time-series of highly accurate gravitational deflection of light in the immediate proximity to the Sun, along with measurements of the Shapiro time delay on interplanetary scales (to a precision respectively better than 0.1 picoradians and 1 cm), LATOR will significantly improve our knowledge of relativistic gravity. The primary mission objective is to i) measure the key post-Newtonian Eddington parameter \gamma with accuracy of a part in 10^9. (1-\gamma) is a direct measure for presence of a new interaction in gravitational theory, and, in its search, LATOR goes a factor 30,000 beyond the present best result, Cassini's 2003 test. The mission will also provide: ii) first measurement of gravity's non-linear effects on light to ~0.01% accuracy; including both the Eddington \beta parameter and also the spatial metric's 2nd order potential contribution (never measured before); iii) direct measurement of the solar quadrupole moment J2 (currently unavailable) to accuracy of a part in 200 of its expected size; iv) direct measurement of the "frame-dragging" effect on light by the Sun's gravitomagnetic field, to 1% accuracy. LATOR's primary measurement pushes to unprecedented accuracy the search for cosmologically relevant scalar-tensor theories of gravity by looking for a remnant scalar field in today's solar system. We discuss the mission design of this proposed experiment.Comment: 8 pages, 9 figures; invited talk given at the 2005 ESLAB Symposium "Trends in Space Science and Cosmic Vision 2020," 19-21 April 2005, ESTEC, Noodrwijk, The Netherland

    Palomar Testbed Interferometer

    Get PDF
    The Palomar Testbed Interferometer (PTI) is an infrared, phase-tracking interferometer in operation at Palomar Mountain since July 1995. It was funded by NASA for the purpose of developing techniques and methodologies for doing narrowangle astrometry for the purpose of detecting extrasolar planets. The instrument employs active fringe trackingin the infrared (2.0-2.4 μm) to monitor fringe phase. It is a dual-star interferometer; it is able to measure fringes on two separate stars simultaneously. An end-to-end heterodyne laser metrology system is used to monitor the optical path length of the starlight. Recently completed engineering upgrades have improved the initial instrument performance. These upgrades are:extended wavelength coverage, a single mode fiber for spatial filtering, vacuum pipes to relay the beams, accelerometers on the siderostat mirrors and a new baseline. Results of recent astrometry data indicate the instrument is approaching the astrometric limit as set by the atmosphere

    The comparison of grey-scale ultrasonic and clinical features of hepatoblastoma and hepatocellular carcinoma in children: a retrospective study for ten years

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hepatoblastoma (HBL) and hepatocellular carcinoma (HCC) are respectively the first and the second most common pediatric malignant liver tumors. The purpose of this study was to evaluate the combined use of the ultrasound examination and the assessment of the patients' clinical features for differentiating HBL from HCC in children.</p> <p>Methods</p> <p>Thirty cases of the confirmed HBL and 12 cases of the confirmed HCC in children under the age of 15 years were enrolled into our study. They were divided into the HBL group and the HCC group according to the histological types of the tumors. The ultrasonic features and the clinical manifestations of the two groups were retrospectively analyzed, with an emphasis on the following parameters: onset age, gender (male/female) ratio, positive epatitis-B-surface-antigen (HBV), alpha-fetoprotein increase, and echo features including septa, calcification and liquefaction within the tumors.</p> <p>Results</p> <p>Compared with the children with HCC, the children with HBL had a significantly younger onset age (8.2 years vs. 3.9 years, P < 0.001) and a significantly smaller frequency of positive HBV (66.7% vs. 13.3%, P < 0.001). The septa and liquefaction were more frequently found in HBL than in HCC (25/30, 83.3% vs. 2/12, 16.7%, P < 0.001; 17/30, 56.7% vs. 3/12, 25%, P = 0.02). When a combination of the liquefaction, septa, negative HBV and onset age smaller than 5 years was used in the evaluation, the sensitivity was raised to 90%, the accuracy was raised to 88%, and the negative predictive value was raised to 73%.</p> <p>Conclusion</p> <p>Ultrasonic features combined with clinical manifestations are valuable for differentiating HBL from HCC in children.</p

    Protein Phosphatase 2A Mediates Dormancy of Glioblastoma Multiforme-Derived Tumor Stem-Like Cells during Hypoxia

    Get PDF
    The hypoxic microenvironment of glioblastoma multiforme (GBM) is thought to increase resistance to cancer therapies. Recent evidence suggests that hypoxia induces protein phosphatase 2A (PP2A), a regulator of cell cycle and cell death. The effects of PP2A on GBM tumor cell proliferation and survival during hypoxic conditions have not been studied.Expression of PP2A subunits and HIF-α proteins was measured in 65 high-grade astrocytoma and 18 non-neoplastic surgical brain specimens by western blotting. PP2A activity was measured by an immunoprecipitation assay. For in vitro experiments, GBM-derived tumor stem cell-like cells (TSCs) were exposed to severe hypoxia produced by either CoCl₂ or 1% O₂. PP2A activity was inhibited either by okadaic acid or by shRNA depletion of the PP2A C subunit. Effects of PP2A activity on cell cycle progression and cell survival during hypoxic conditions were assessed using flow cytometry.In our patient cohort, PP2A activity was positively correlated with HIF-1∝ protein expression (P = 0.002). Patients with PP2A activity levels above 160 pMP had significantly worse survival compared to patients with levels below this threshold (P = 0.002). PP2A activity was an independent predictor of survival on multivariable analysis (P = 0.009). In our in vitro experiments, we confirmed that severe hypoxia induces PP2A activity in TSCs 6 hours after onset of exposure. PP2A activity mediated G1/S phase growth inhibition and reduced cellular ATP consumption in hypoxic TSCs. Conversely, inhibition of PP2A activity led to increased cell proliferation, exhaustion of intracellular ATP, and accelerated P53-independent cell death of hypoxic TSCs.Our results suggest that PP2A activity predicts poor survival in GBM. PP2A appears to reduce the metabolic demand of hypoxic TSCs and enhances tumor cell survival. Modulation of PP2A may be a potential target for cancer therapy
    corecore