266 research outputs found
Incoherency in Central American Hydroclimate Proxy Records Spanning the Last Millennium
Continued Global Warming is Expected to Result in Reduced Precipitation and a Drier Climate in Central America. Projections of Future Changes Are Highly Uncertain, However, Due to the Spatial Resolution Limitations of Models and Insufficient Observational Data Coverage Across Space and Time. Paleoclimate Proxy Data Are Therefore Critical for Understanding Regional Climate Responses during Times of Global Climate Reorganization. Here We Present Two Lake-Sediment based Records of Precipitation Variability in Guatemala Along with a Synthesis of Central American Hydroclimate Records Spanning the Last Millennium (800–2000 CE). the Synthesis Reveals that Regional Climate Changes Have Been Strikingly Heterogeneous, even over Relatively Short Distances. Our Analysis Further Suggests that Shifts in the Mean Position of the Intertropical Convergence Zone, Which Have Been Invoked by Numerous Studies to Explain Variability in Central American and Circum-Caribbean Proxy Records, Cannot Alone Explain the Observed Pattern of Hydroclimate Variability. Instead, Interactions between Several Ocean-Atmosphere Processes and their Disparate Influences Across Variable Topography Appear to Have Resulted in Complex Precipitation Responses. These Complexities Highlight the Difficulty of Reconstructing Past Precipitation Changes Across Central America and Point to the Need for Additional Paleo-Record Development and Analysis Before the Relationships between External Forcing and Hydroclimate Change Can Be Robustly Determined. Such Efforts Should Help Anchor Model-Based Predictions of Future Responses to Continued Global Warming
Spectrally-resolved Imaging of the Transverse Modes in Multimode VCSELs
Vertical-cavity surface-emitting lasers (VCSELs) enable a range of applications such as data transmission, trace sensing, atomic clocks, and optical mice. For many of these applications, the output power and beam quality are both critical (i.e. high output power with good beam quality is desired). Multi-mode VCSELs offer much higher power than single-mode devices, but this comes at the expense of lower beam quality. Directly observing the resolved mode structure of multi-mode VCSELs would enable engineers to better understand the underlying physics and help them to develop multi-mode devices with improved beam quality. In this work, a low-cost, high-resolution (\u3c3 \u3epm) Echelle grating spectrometer system is used to map the two-dimensional VCSEL near-field emission profile. The system spectrally disperses the VCSEL beam and images it with high magnification onto a CMOS camera. The narrow spectral content of each LP mode allows direct observation of the modal content of the VCSEL
Temperature of the Plasmasphere from Van Allen Probes HOPE
We introduce two novel techniques for estimating temperatures of very low energy space plasmas using, primarily, in situ data from an electrostatic analyzer mounted on a charged and moving spacecraft. The techniques are used to estimate proton temperatures during intervals where the bulk of the ion plasma is well below the energy bandpass of the analyzer. Both techniques assume that the plasma may be described by a one-dimensional E→×B→ drifting Maxwellian and that the potential field and motion of the spacecraft may be accounted for in the simplest possible manner, i.e., by a linear shift of coordinates. The first technique involves the application of a constrained theoretical fit to a measured distribution function. The second technique involves the comparison of total and partial-energy number densities. Both techniques are applied to Van Allen Probes Helium, Oxygen, Proton, and Electron (HOPE) observations of the proton component of the plasmasphere during two orbits on 15 January 2013. We find that the temperatures calculated from these two order-of-magnitude-type techniques are in good agreement with typical ranges of the plasmaspheric temperature calculated using retarding potential analyzer-based measurements—generally between 0.2 and 2 eV (2000–20,000 K). We also find that the temperature is correlated with L shell and hot plasma density and is negatively correlated with the cold plasma density. We posit that the latter of these three relationships may be indicative of collisional or wave-driven heating of the plasmasphere in the ring current overlap region. We note that these techniques may be easily applied to similar data sets or used for a variety of purposes
Replacement of Hydrochlorofluorocarbon (HCFC) -225 Solvent for Cleaning and Verification Sampling of NASA Propulsion Oxygen Systems Hardware, Ground Support Equipment, and Associated Test Systems
Since the 1990's, NASA's rocket propulsion test facilities at Marshall Space Flight Center (MSFC) and Stennis Space Center (SSC) have used hydrochlorofluorocarbon-225 (HCFC-225), a Class II ozone-depleting substance, to safety clean and verify the cleanliness of large scale propulsion oxygen systems and associated test facilities. In 2012 through 2014, test laboratories at MSFC, SSC, and Johnson Space Center-White Sands Test Facility collaborated to seek out, test, and qualify an environmentally preferred replacement for HCFC-225. Candidate solvents were selected, a test plan was developed, and the products were tested for materials compatibility, oxygen compatibility, cleaning effectiveness, and suitability for use in cleanliness verification and field cleaning operations. Honewell Soltice (TradeMark) Performance Fluid (trans-1-chloro-3,3, 3-trifluoropropene) was selected to replace HCFC-225 at NASA's MSFC and SSC rocket propulsion test facilities
Development of a Definition of Postacute Sequelae of SARS-CoV-2 Infection
IMPORTANCE: SARS-CoV-2 infection is associated with persistent, relapsing, or new symptoms or other health effects occurring after acute infection, termed postacute sequelae of SARS-CoV-2 infection (PASC), also known as long COVID. Characterizing PASC requires analysis of prospectively and uniformly collected data from diverse uninfected and infected individuals.
OBJECTIVE: To develop a definition of PASC using self-reported symptoms and describe PASC frequencies across cohorts, vaccination status, and number of infections.
DESIGN, SETTING, AND PARTICIPANTS: Prospective observational cohort study of adults with and without SARS-CoV-2 infection at 85 enrolling sites (hospitals, health centers, community organizations) located in 33 states plus Washington, DC, and Puerto Rico. Participants who were enrolled in the RECOVER adult cohort before April 10, 2023, completed a symptom survey 6 months or more after acute symptom onset or test date. Selection included population-based, volunteer, and convenience sampling.
EXPOSURE: SARS-CoV-2 infection.
MAIN OUTCOMES AND MEASURES: PASC and 44 participant-reported symptoms (with severity thresholds).
RESULTS: A total of 9764 participants (89% SARS-CoV-2 infected; 71% female; 16% Hispanic/Latino; 15% non-Hispanic Black; median age, 47 years [IQR, 35-60]) met selection criteria. Adjusted odds ratios were 1.5 or greater (infected vs uninfected participants) for 37 symptoms. Symptoms contributing to PASC score included postexertional malaise, fatigue, brain fog, dizziness, gastrointestinal symptoms, palpitations, changes in sexual desire or capacity, loss of or change in smell or taste, thirst, chronic cough, chest pain, and abnormal movements. Among 2231 participants first infected on or after December 1, 2021, and enrolled within 30 days of infection, 224 (10% [95% CI, 8.8%-11%]) were PASC positive at 6 months.
CONCLUSIONS AND RELEVANCE: A definition of PASC was developed based on symptoms in a prospective cohort study. As a first step to providing a framework for other investigations, iterative refinement that further incorporates other clinical features is needed to support actionable definitions of PASC
A new species of Aedes from the Caroline Islands.(Diptera, Culicidae)
Volume: 58Start Page: 59End Page: 6
- …