99 research outputs found

    Unrelated donor vs HLA-haploidentical a/b T-cell- and B-cell-depleted HSCT in children with acute leukemia

    Get PDF
    Traditionally, hematopoietic stem cell transplantation (HSCT) from both HLA-matched related and unrelated donors (UD) has been used for treating children with acute leukemia (AL) in need of an allograft. Recently, HLA-haploidentical HSCT after ab T-cell/B-cell depletion (abhaplo-HSCT) was shown to be effective in single-center studies. Here, we report the first multicenter retrospective analysis of 127 matched UD (MUD), 118 mismatched UD (MMUD), and 98 abhaplo-HSCT recipients, transplanted between 2010 and 2015, in 13 Italian centers. All these AL children were transplanted in morphological remission after a myeloablative conditioning regimen. Graft failure occurred in 2% each of UD-HSCT and abhaplo-HSCT groups. In MUD vs MMUD-HSCT recipients, the cumulative incidence of grade II to IV and grade III to IV acute graft-versus-host disease (GVHD) was 35% vs 44% and 6% vs 18%, respectively, compared with 16% and 0% in abhaplo-HSCT recipients (P < .001). Children treated with abhaplo-HSCT also had a significantly lower incidence of overall and extensive chronic GVHD (P < .01). Eight (6%) MUD, 32 (28%) MMUD, and 9 (9%) abhaplo-HSCT patients died of transplant-related complications. With a median follow-up of 3.3 years, the 5-year probability of leukemia-free survival in the 3 groups was 67%, 55%, and 62%, respectively. In the 3 groups, chronic GVHD-free/relapse-free (GRFS) probability of survival was 61%, 34%, and 58%, respectively (P < .001). When compared with patients given MMUD-HSCT, abhaplo-HSCT recipients had a lower cumulative incidence of nonrelapse mortality and a better GRFS (P < .001). These data indicate that abhaplo-HSCT is a suitable therapeutic option for children with AL in need of transplantation, especially when an allele-matched UD is not available

    Saccadic Eye Movements Minimize the Consequences of Motor Noise

    Get PDF
    The durations and trajectories of our saccadic eye movements are remarkably stereotyped. We have no voluntary control over these properties but they are determined by the movement amplitude and, to a smaller extent, also by the movement direction and initial eye orientation. Here we show that the stereotyped durations and trajectories are optimal for minimizing the variability in saccade endpoints that is caused by motor noise. The optimal duration can be understood from the nature of the motor noise, which is a combination of signal-dependent noise favoring long durations, and constant noise, which prefers short durations. The different durations of horizontal vs. vertical and of centripetal vs. centrifugal saccades, and the somewhat surprising properties of saccades in oblique directions are also accurately predicted by the principle of minimizing movement variability. The simple and sensible principle of minimizing the consequences of motor noise thus explains the full stereotypy of saccadic eye movements. This suggests that saccades are so stereotyped because that is the best strategy to minimize movement errors for an open-loop motor system

    Update on Hemicrania Continua

    Get PDF
    Hemicrania continua (HC) is a rare primary headache syndrome, characterized by unilateral pain and an absolute response to indometacin. Since the term was first coined in 1984, more than 100 cases have been described worldwide. Most recently, detailed case series that provide more detailed information concerning the sometimes complex clinical presentation of HC have been reported. Functional imaging studies suggest a unique pattern of subcortical involvement in HC: contralateral to the pain posterior hypothalamic region, ipsilateral dorsal pons and ipsilateral ventral midbrain, which, along with the particular effect of indometacin, probably justifies its classification as a unique entity. Increasing the awareness of this primary headache form among clinicians will aid in its diagnosis while further work is being undertaken to characterize the syndrome

    Image perception and interpretation of abnormalities; can we believe our eyes? Can we do something about it?

    Get PDF
    The radiologist’s visual impression of images is transmitted, via non-visual means (the report), to the clinician. There are several complex steps from the perception of the images by the radiologist to the understanding of the impression by the clinician. With a process as complex as this, it is no wonder that errors in perception, cognition, interpretation, transmission and understanding are very common. This paper reviews the processes of perception and error generation and possible strategies for minimising them

    Pregabalin versus Pramipexole for Restless Legs Syndrome

    No full text

    {SacCalib}: {R}educing Calibration Distortion for Stationary Eye Trackers Using Saccadic Eye Movements

    No full text
    Recent methods to automatically calibrate stationary eye trackers were shown to effectively reduce inherent calibration distortion. However, these methods require additional information, such as mouse clicks or on-screen content. We propose the first method that only requires users' eye movements to reduce calibration distortion in the background while users naturally look at an interface. Our method exploits that calibration distortion makes straight saccade trajectories appear curved between the saccadic start and end points. We show that this curving effect is systematic and the result of distorted gaze projection plane. To mitigate calibration distortion, our method undistorts this plane by straightening saccade trajectories using image warping. We show that this approach improves over the common six-point calibration and is promising for reducing distortion. As such, it provides a non-intrusive solution to alleviating accuracy decrease of eye tracker during long-term use
    • …
    corecore