226 research outputs found
Alternative Mathematical Technique to Determine LS Spectral Terms
We presented an alternative computational method for determining the
permitted LS spectral terms arising from electronic configurations. This
method makes the direct calculation of LS terms possible. Using only basic
algebra, we derived our theory from LS-coupling scheme and Pauli exclusion
principle. As an application, we have performed the most complete set of
calculations to date of the spectral terms arising from electronic
configurations, and the representative results were shown. As another
application on deducing LS-coupling rules, for two equivalent electrons, we
deduced the famous Even Rule; for three equivalent electrons, we derived a new
simple rule.Comment: Submitted to Phys. Rev.
Isotope shift in the electron affinity of chlorine
The specific mass shift in the electron affinity between ^{35}Cl and ^{37}Cl
has been determined by tunable laser photodetachment spectroscopy to be
-0.51(14) GHz. The isotope shift was observed as a difference in the onset of
the photodetachment process for the two isotopes. In addition, the electron
affinity of Cl was found to be 29138.59(22) cm^{-1}, giving a factor of 2
improvement in the accuracy over earlier measurements. Many-body calculations
including lowest-order correlation effects demonstrates the sensitivity of the
specific mass shift and show that the inclusion of higher-order correlation
effects would be necessary for a quantitative description.Comment: 16 pages, 6 figures, LaTeX2e, amsmat
Calculations of parity nonconserving s-d transitions in Cs, Fr, Ba II, and Ra II
We have performed ab initio mixed-states and sum-over-states calculations of
parity nonconserving (PNC) electric dipole (E1) transition amplitudes between
s-d electron states of Cs, Fr, Ba II, and Ra II. For the lower states of these
atoms we have also calculated energies, E1 transition amplitudes, and
lifetimes. We have shown that PNC E1 transition amplitudes between s-d states
can be calculated to high accuracy. Contrary to the Cs 6s-7s transition, in
these transitions there are no strong cancelations between different terms in
the sum-over-states approach. In fact, there is one dominating term which
deviates from the sum by less than 20%. This term corresponds to an s-p_{1/2}
weak matrix element, which can be calculated to better than 1%, and a
p_{1/2}-d_{3/2} E1 transition amplitude, which can be measured. Also, the s-d
amplitudes are about four times larger than the corresponding s-s transitions.
We have shown that by using a hybrid mixed-states/sum-over-states approach the
accuracy of the calculations of PNC s-d amplitudes could compete with that of
Cs 6s-7s if p_{1/2}-d_{3/2} E1 amplitudes are measured to high accuracy.Comment: 15 pages, 8 figures, submitted to Phys. Rev.
Measurement and application of electron stripping of ultrarelativistic
New measurements of the stripping cross-section for ultrarelativistic
hydrogen-like lead ions passing through aluminium and silicon have been
performed at the Advanced Wakefield experiment at CERN. Agreement with existing
measurements and theory has been obtained. Improvements in terms of electron
beam quality and ion beam diagnostic capability, as well as further
applications of such an electron beam, are discussed
A facility to Search for Hidden Particles (SHiP) at the CERN SPS
A new general purpose fixed target facility is proposed at the CERN SPS
accelerator which is aimed at exploring the domain of hidden particles and make
measurements with tau neutrinos. Hidden particles are predicted by a large
number of models beyond the Standard Model. The high intensity of the SPS
400~GeV beam allows probing a wide variety of models containing light
long-lived exotic particles with masses below (10)~GeV/c,
including very weakly interacting low-energy SUSY states. The experimental
programme of the proposed facility is capable of being extended in the future,
e.g. to include direct searches for Dark Matter and Lepton Flavour Violation.Comment: Technical Proposa
UTA versus line emission for EUVL: Studies on xenon emission at the NIST EBIT
Spectra from xenon ions have been recorded at the NIST EBIT and the emission
into a 2% bandwidth at 13.5 nm arising from 4d-5p transitions compared with
that from 4d-4f and 4p-4d transitions in Xe XI and also with that obtained from
the unresolved transition array (UTA) observed to peak just below 11 nm. It was
found that an improvement of a factor of five could be gained in photon yield
using the UTA rather than the 4d-5p emission. The results are compared with
atomic structure calculations and imply that a significant gain in efficiency
should be obtained using tin, in which the emission at 13.5 nm comes from a
similar UTA, rather than xenon as an EUVL source material
Track reconstruction and matching between emulsion and silicon pixel detectors for the SHiP-charm experiment
In July 2018 an optimization run for the proposed charm cross section measurement for SHiP was performed at the CERN SPS. A heavy, moving target instrumented with nuclear emulsion films followed by a silicon pixel tracker was installed in front of the Goliath magnet at the H4 proton beam-line. Behind the magnet, scintillating-fibre, drift-tube and RPC detectors were placed. The purpose of this run was to validate the measurement's feasibility, to develop the required analysis tools and fine-tune the detector layout. In this paper, we present the track reconstruction in the pixel tracker and the track matching with the moving emulsion detector. The pixel detector performed as expected and it is shown that, after proper alignment, a vertex matching rate of 87% is achieved
Female rats are relatively more sensitive to reduced lipid versus reduced carbohydrate availability
The SHiP experiment at the proposed CERN SPS Beam Dump Facility
The Search for Hidden Particles (SHiP) Collaboration has proposed a general-purpose experimental facility operating in beam-dump mode at the CERN SPS accelerator to search for light, feebly interacting particles. In the baseline configuration, the SHiP experiment incorporates two complementary detectors. The upstream detector is designed for recoil signatures of light dark matter (LDM) scattering and for neutrino physics, in particular with tau neutrinos. It consists of a spectrometer magnet housing a layered detector system with high-density LDM/neutrino target plates, emulsion-film technology and electronic high-precision tracking. The total detector target mass amounts to about eight tonnes. The downstream detector system aims at measuring visible decays of feebly interacting particles to both fully reconstructed final states and to partially reconstructed final states with neutrinos, in a nearly background-free environment. The detector consists of a 50 long decay volume under vacuum followed by a spectrometer and particle identification system with a rectangular acceptance of 5Â m in width and 10Â m in height. Using the high-intensity beam of 400 protons, the experiment aims at profiting from the protons per year that are currently unexploited at the SPS, over a period of 5â10 years. This allows probing dark photons, dark scalars and pseudo-scalars, and heavy neutral leptons with GeV-scale masses in the direct searches at sensitivities that largely exceed those of existing and projected experiments. The sensitivity to light dark matter through scattering reaches well below the dark matter relic density limits in the range from a few up to 100Â MeV-scale masses, and it will be possible to study tau neutrino interactions with unprecedented statistics. This paper describes the SHiP experiment baseline setup and the detector systems, together with performance results from prototypes in test beams, as it was prepared for the 2020 Update of the European Strategy for Particle Physics. The expected detector performance from simulation is summarised at the end
- âŠ