15 research outputs found

    Imaging ischemic and reperfusion injury in acute myocardial infarction putting the pieces together with CMR

    Get PDF
    rom the a Department of Imaging and Pathology, KU Leuven – University of Leuven, Leuven, Belgium; b Lab on Cardiovascular Imaging and Dynamics, Department of Cardiovascular Sciences, KU Leuven – University of Leuven, Leuven, Belgium; c Life and Health Sciences Research Institute/Biomaterials, Biodegradables and Biomimetics Research Group — Portugal Government Associate Laboratory, Braga/Guimarães, Portugal; d Instituto de Engenharia Mecânica e Gestão Industrial, Faculdade de Engenharia, Universidade do Porto, Porto, Portugal; and the e Medical Imaging Research Center, ESAT-PSI, Processing Speech and Images (PSI), Department of Electrical Engineering (ESAT), KU Leuven, Leuven, Belgium. Dr. Morais has received funding for his PhD scholarship (FCT — Fundacão para a Ciência e a Tecnologia, Portugal, for funding support through the Programa Operacional Capital Humano in the scope of the PhD grant SFRH/BD/95438/2013). All other authors have reported that they have no relationships relevant to the contents of this paper to disclose.info:eu-repo/semantics/publishedVersio

    MR imaging of primary benign cardiac tumors in the pediatric population

    Get PDF
    Primary cardiac tumors are rare in all ages, especially in children, with a reported prevalence range of 0.0017–0.28% in autopsy series. Due to their rarity, the diagnostic and therapeutic pathways reserved to them are usually described by single case reports, leading to the point where a common diagnostic protocol is imperative to obtain a differential diagnosis. The first diagnostic approach is done with transthoracic echocardiogram (TTE), due to its wide availability, low cost, absence of ionizing radiations and non-invasiveness. Several tumors are discovered incidentally and, in many cases, TTE is helpful to determine location, size and anatomical features, playing a key role in the differential diagnosis. In the last few years, cardiac magnetic resonance imaging (CMR) has had an increased role in the diagnostic pathway of pediatric cardiac masses, due to its high accuracy in characterizing mass tissue properties (especially for soft tissue), and in detecting tumor size, extent, pericardial/pleural effusion, leading to the correct diagnosis, treatment and follow-up. Therefore, nowadays, several consensus statements consider CMR as a leading imaging technique, thanks to its non-invasive tissue characterization, without the use of ionizing radiation, in an unrestricted field of view. As suggested by the most recent literature, the pediatric protocol is not so different from the adult one, adapted to the size and cardiac frequency of the patient, sometimes requiring special conditions such as free-breathing sequences and/or sedation or general anesthesia in non-cooperating patients.</p

    Risk Factors of Right Ventricular Dysfunction and Adverse Cardiac Events in Patients with Repaired Tetralogy of Fallot

    Get PDF
    Aim: This study evaluates the risk factors associated with right ventricular (RV) dilation and dysfunction leading to pulmonary valve replacement (PVR) or adverse cardiac events in repaired Tetralogy of Fallot (rToF) patients. Methods: Data from all rToF patients who underwent magnetic resonance imaging (MRI) evaluation at our hospital between February 2007 and September 2020 were collected. Results: Three hundred and forty-two patients (60% males, 42% older than 18 years), with a median age of 16 years (IQR 13–24) at the time of MRI, were included. All patients underwent complete repair at a median age of 8 months (IQR 5–16), while palliation was performed in 56 patients (16%). One hundred and forty-four patients (42%) subsequently received pulmonary valve replacement (PVR). At the multivariate analysis, male gender was an independent predictor for significant RV dilation, RV and left ventricular (LV) dysfunction. Transventricular ventricular septal defect (VSD) closure and previous palliation significantly affected LV function and RV size, respectively. Male gender and the transventricular VSD closure were independent predictors for PVR. Conclusions: Male gender and surgical history (palliation, VSD closure approach) significantly affected the long-term outcomes in rToF patients and should be taken into consideration in the follow-up management and in PVR timing in this patient population

    Is MRI imaging in pediatric age totally safe? A critical reprisal

    Get PDF
    Current radiological literature is strongly focussed on radiation imaging risks. Indeed, given there is a small but actual augment in cancer risk from exposure to ionizing radiation in children, it is important to understand what the risk of alternative techniques could be. We retrospectively review literature data concerning possible MR imaging risks, focussing on the biological effects of MR, sedation and gadolinium compound risks when dealing with infant patients. The main concerns can be summarized in: (1) Biological effects of non-ionizing electromagnetic fields (EMF) employed—whose mechanisms of interaction with human tissues are polarization, induced current, and thermal heating, respectively. (2) Risks associated with noises produced during MRI examinations. (3) Hazards from ferromagnetic external and/or implanted devices—whose risk of being unintentionally brought inside MR room is higher in children than in adults. (4) Risks associated with sedation or general anaesthesia, essential problem in performing MR in very young patients, due to the exam long-lasting. (5) Risks related to gadolinium-based contrast agents, especially considering the newly reported brain deposition

    Coronary computed tomography angiography, ECG stress test and nuclear imaging as sources of false-positive results in the detection of coronary artery disease

    No full text
    The most important goal of a diagnostic test is to discriminate patients with from patients without disease. The accuracy of a diagnostic test is evaluated by comparing the results of a test with a \u2018gold standard\u2019, that is, with a test considered by most as the actual means to achieve an unequivocal diagnosis. In cardiology, invasive coronary angiography (ICA) has been usually deemed the means to diagnose coronary artery disease (CAD); however, apart from not being devoid of risks, ICA only depicts the anatomical severity of a coronary lesion, but cannot accurately identify its hemodynamic relevance, that is frequently confirmed with fractional flow reserve (FFR), as invasively assessed through the measurement of coronary pressure distal to the lesion after minimization of microvascular resistance \u2013 usually with adenosine intra venous infusion or intracoronary bolus. Therefore, there is a clinical need for accurate, noninvasive tests that would allow the making of a diagnosis in a simpler, noninvasive, less risky, and in a repeatable way

    Left ventricular global myocardial strain assessment comparing the reproducibility of four commercially available CMR-feature tracking algorithms

    No full text
    OBJECTIVES: To compare the reproducibility of cardiovascular magnetic resonance feature-tracking (CMR-FT) packages to assess global left ventricular (LV) myocardial strain. METHODS: In 45 subjects (i.e. 15 controls, 15 acute myocardial infarction, 15 dilated cardiomyopathy patients), we determined inter-vendor, inter-observer (two readers) and intra-observer reproducibility of peak systolic global radial, circumferential and longitudinal strain (GRS, GCS and GLS, respectively) comparing four commercially available software packages. Differences between vendors were assessed with analysis of variance (ANOVA), between observers and readings with intraclass correlation coefficient (ICC) and coefficient of variation (CV). RESULTS: The normalised end-diastolic volume was 91, 77 and 119 ml/m2 (median, Q1, Q3) and ejection fraction was 41 ± 14%, range 12-67%. Global longitudinal strain (GLS), global circumferential strain (GCS) and global radial strain (GRS) values were 13.9% ± 5.4% (3.9-23.8%), 12.2% ± 5.8% (1.0-25.1%) and 32.0% ± 14.7 (3.6-67.8%), respectively. ANOVA showed significant differences between vendors for GRS (p < 0.001) and GLS (p = 0.018), not for GCS (p = 0.379). No significant bias was found for both intra- and inter-observer variability. The ICC for inter- and intra-observer reproducibility ranged 0.828-0.991 and 0.902-0.997, respectively. The CV, however, ranged considerably, i.e. 4.0-28.8% and 2.8- 27.7% for inter- and intra-observer reproducibility, respectively. In particular, for GRS differences in CV values between vendors were large, i.e. 5.2-28.8% and 2.8-27.7%, for inter- and intra-observer reproducibility, respectively. CONCLUSIONS: In a cohort of subjects with a wide range of cardiac performances, GRS and GLS values are not interchangeable between vendors. Moreover, although intra- and inter-observer reproducibility amongst vendors is excellent, some vendors encounter problems to reproducibly measure global radial strain. KEY POINTS: • Different software packages are currently available for myocardial strain assessment using routinely acquired cine CMR images. • Global myocardial strain values are not interchangeable between vendors for global longitudinal and global radial strain. • Inter- and intra-observer reproducibility for global strain assessment is excellent. However, some vendors encounter problems to reproducibly measure global radial strain.status: publishe

    Inter-vendor reproducibility and accuracy of segmental left ventricular strain measurements using CMR feature tracking

    No full text
    OBJECTIVES: Our aim was to evaluate the inter-vendor reproducibility of cardiovascular MR feature tracking (CMR-FT) for the measurement of segmental strain (SS) of the left ventricle (LV) as well as to test the accuracy of CMR-FT to detect regional myocardial pathology. METHODS: We selected 45 patients: 15 with normal CMR findings, 15 with dilated cardiomyopathy, and 15 with acute myocardial infarction. Segmental longitudinal, circumferential, and radial strains were assessed with 4 different software. The inter-vendor difference as well as intra- and inter-observer variability was investigated. Furthermore, the accuracy of CMR-FT for the detection of structural (infarcted segments) as well as functional pathology (septal vs. lateral wall strain in left bundle branch block) was tested. RESULTS: Between vendors, there were significant differences in values for all strains (p  0.962 and coefficient of variation (CV) < 24%. For infarct location, the same software yielded the highest area under the curve values for radial and circumferential SS (0.872 and 0.859, respectively). One of the other three software using optical flow technology performed best for longitudinal SS (0.799) and showed the largest differences in SS between septum and lateral wall in the dilated cardiomyopathy group. CONCLUSION: SS values obtained by CMR-FT are not interchangeable between vendors, and intra- and inter-observer reproducibility shows substantial variability among vendors. Overall, the different packages score relatively well to depict focal structural or functional LV pathology. KEY POINTS: • Segmental myocardial strain values obtained by CMR feature tracking are not interchangeable between different vendors. • Intra- and inter-observer reproducibility shows substantial variability among vendors. • Segmental myocardial strains measured by CMR feature tracking score relatively well to depict focal structural or functional LV pathology.status: publishe

    Pediatric Cardiovascular Computed Tomography: Clinical Indications, Technique, and Standardized Reporting. Recommendations From the Cardiothoracic Taskforce of the European Society of Pediatric Radiology

    Full text link
    Congenital heart diseases affect 1% of all live births in the general population. The prognosis of these children is increasingly improving due to advances in medical care and surgical treatment. Imaging is also evolving rapidly to assess accurately complex cardiac anomalies prenatally and postnatally. Transthoracic echocardiography is the gold-standard imaging technique to diagnose and follow-up children with congenital heart disease. Cardiac computed tomography imaging plays a key role in the diagnosis of children with congenital heart defects that require intervention, due to its high temporal and spatial resolution, with low radiation doses. It is challenging for radiologists, not primarily specialized in this field, to perform and interpret these studies due to the difficult anatomy, physiology, and postsurgical changes. Technical challenges consist of necessary electrocardiogram gating and contrast bolus timing to obtain an optimal examination. This article aims to define indications for pediatric cardiac computed tomography, to explain how to perform and report these studies, and to discuss future applications of this technique

    Relapsing myocarditis following initial recovery of post COVID-19 vaccination in two adolescent males – Case reports

    No full text
    Whilst there has been significant public health benefits associated with global use of COVID-19 spike protein vaccines, potential serious adverse events following immunization have been reported. Acute myocarditis is a rare complication of COVID19 vaccines and often it is self-limiting. We describe two cases experiencing recurrent myocarditis following mRNA COVID-19 vaccine despite a prior episode with full clinical recovery. Between September 2021-September 2022 we observed two male adolescents with recurrent myocarditis related to mRNA-based-COVID19 vaccine. During the first episode both patients presented with fever and chest pain few days after their second dose of BNT162b2 mRNA Covid-19 Vaccine (Comirnaty®). The blood exams showed increased cardiac enzymes. In addition, complete viral panel was run, showing HHV7 positivity in a single case. The left ventricular ejection fraction (LVEF) was normal at echocardiogram but cardiac magnetic resonance scanning (CMR) was consistent with myocarditis. They were treated with supportive treatment with full recovery. The 6 months follow-up demonstrated good clinical conditions with normal cardiological findings. The CMR showed persistent lesions in left ventricle ‘s wall with LGE. After some months the patients presented at emergency department with fever and chest pain and increased cardiac enzymes. No decreased LVEF was observed. The CMR showed new focal areas of edema in the first case report and stable lesions in the second one. They reached full recovery with normalization of cardiac enzymes after few days. These case reports outline the need of strict follow-up in patients with CMR consistent with myocarditis after mRNA-based-COVID19 vaccine. More efforts are necessary to depict the underlying mechanisms of myocarditis after SARS-CoV2 vaccination to understand the risk of relapsing and the long-term sequelae
    corecore