1,070 research outputs found

    A Time Series Analysis of Air Pollution and Preterm Birth in Pennsylvania, 1997–2001

    Get PDF
    Preterm delivery can lead to serious infant health outcomes, including death and lifelong disability. Small increases in preterm delivery risk in relation to spatial gradients of air pollution have been reported, but previous studies may have controlled inadequately for individual factors. Using a time-series analysis, which eliminates potential confounding by individual risk factors that do not change over short periods of time, we investigated the effect of ambient outdoor particulate matter with diameter ≤10 μm (PM(10)) and sulfur dioxide on risk for preterm delivery. Daily counts of preterm births were obtained from birth records in four Pennsylvania counties from 1997 through 2001. We observed increased risk for preterm delivery with exposure to average PM(10) and SO(2) in the 6 weeks before birth [respectively, relative risk (RR) = 1.07; 95% confidence interval (CI), 0.98–1.18 per 50 μg/m(3) increase; RR = 1.15; 95% CI, 1.00–1. 32 per 15 ppb increase], adjusting for long-term preterm delivery trends, co-pollutants, and offsetting by the number of gestations at risk. We also examined lags up to 7 days before the birth and found an acute effect of exposure to PM(10) 2 days and 5 days before birth (respectively, RR = 1.10; 95% CI, 1.00–1.21; RR = 1.07; 95% CI, 0.98–1.18) and SO(2) 3 days before birth (RR = 1.07; 95% CI, 0.99–1.15), adjusting for covariates, including temperature, dew point temperature, and day of the week. The results from this time-series analysis, which provides evidence of an increase in preterm birth risk with exposure to PM(10) and SO(2), are consistent with prior investigations of spatial contrasts

    Estimation of proteinuria as a predictor of complications of pre-eclampsia: a systematic review

    Get PDF
    Background Proteinuria is one of the essential criteria for the clinical diagnosis of pre-eclampsia. Increasing levels of proteinuria is considered to be associated with adverse maternal and fetal outcomes. We aim to determine the accuracy with which the amount of proteinuria predicts maternal and fetal complications in women with pre-eclampsia by systematic quantitative review of test accuracy studies. Methods We conducted electronic searches in MEDLINE (1951 to 2007), EMBASE (1980 to 2007), the Cochrane Library (2007) and the MEDION database to identify relevant articles and hand-search of selected specialist journals and reference lists of articles. There were no language restrictions for any of these searches. Two reviewers independently selected those articles in which the accuracy of proteinuria estimate was evaluated to predict maternal and fetal complications of pre-eclampsia. Data were extracted on study characteristics, quality and accuracy to construct 2 × 2 tables with maternal and fetal complications as reference standards. Results Sixteen primary articles with a total of 6749 women met the selection criteria with levels of proteinuria estimated by urine dipstick, 24-hour urine proteinuria or urine protein:creatinine ratio as a predictor of complications of pre-eclampsia. All 10 studies predicting maternal outcomes showed that proteinuria is a poor predictor of maternal complications in women with pre-eclampsia. Seventeen studies used laboratory analysis and eight studies bedside analysis to assess the accuracy of proteinuria in predicting fetal and neonatal complications. Summary likelihood ratios of positive and negative tests for the threshold level of 5 g/24 h were 2.0 (95% CI 1.5, 2.7) and 0.53 (95% CI 0.27, 1) for stillbirths, 1.5 (95% CI 0.94, 2.4) and 0.73 (95% CI 0.39, 1.4) for neonatal deaths and 1.5 (95% 1, 2) and 0.78 (95% 0.64, 0.95) for Neonatal Intensive Care Unit admission. Conclusion Measure of proteinuria is a poor predictor of either maternal or fetal complications in women with pre-eclampsia

    Cultural differences in postnatal quality of life among German-speaking women - a prospective survey in two countries.

    Get PDF
    Assessment of quality of life after childbirth is an important health-outcome measurement for new mothers and is of special interest in midwifery. The Mother-Generated Index (MGI) is a validated instrument to assess postnatal quality of life. The tool has not been applied for making a cross-cultural comparison before. This study investigated (a) responses to the MGI in German-speaking women in Germany and Switzerland; and (b) associations between MGI scores on the one hand and maternity and midwifery care on the other

    Modeling repeated ordinal responses using a family of power transformations: application to neonatal hypothermia data

    Get PDF
    BACKGROUND: For analyzing a repeated ordinal response, it is common to use a multivariate cumulative logit model. This model may fit poorly, especially when a nonsymmetric response is available. In these cases, alternative strategies should be utilized. METHODS: In this paper, we present a family of power transformations for the cumulative probabilities to model asymmetric departures from the random-intercept cumulative logit model. To illustrate this method, we analyze the data from an epidemiologic study to identify risk factors of hypothermia among newly born infants in some referral university hospitals in Tehran, Iran. RESULTS: For hypothermia data, using this family of transformations and comparing the goodness-of-fit statistics showed that a model with the cumulative complementary log-log link gives us a better fit compared to a model with the cumulative logit link. CONCLUSION: In some areas, using the ordinary cumulative logit link function does not lead to the best fit. So, other link functions should be evaluated to discover the best transformation for the cumulative probabilities

    “Early Rupture of Membranes” during Induced Labor as a Risk Factor for Cesarean Delivery in Term Nulliparas

    Get PDF
    OBJECTIVE: To determine if "early rupture of membranes" (early ROM) during induction of labor is associated with an increased risk of cesarean section in term nulliparas. STUDY DESIGN: The rate of cesarean section and the timing of ROM during the course of labor were examined in term singleton nulliparas whose labor was induced. Cases were divided into 2 groups according the timing of ROM: 1)"early ROM", defined as ROM at a cervical dilatation<4 cm during labor; and 2) "late ROM", ROM at a cervical dilatation≥4 cm during labor. Nonparametric techniques were used for statistical analysis. RESULTS: 1) In a total of 500 cases of study population, "early ROM" occurred in 43% and the overall cesarean section rate was 15.8%; 2) patients with "early ROM" had a higher rate of cesarean section and cesarean section due to failure to progress than did those with "late ROM" (overall cesarean section rate: 24%[51/215] vs. 10%[28/285], p<0.01; cesarean section rate due to failure to progress: 18%[38/215] vs. 8%[22/285], p<0.01 for each) and this difference remained significant after adjusting for confounding variables. CONCLUSION: "Early ROM" during the course of induced labor is a risk factor for cesarean section in term singleton nulliparas

    Effects of carrying a pregnancy and of method of delivery on urinary incontinence: a prospective cohort study

    Get PDF
    BACKGROUND: This study was carried out to identify risk factors associated with urinary incontinence in women three months after giving birth. METHODS: Urinary incontinence before and during pregnancy was assessed at study enrolment early in the third trimester. Incontinence was re-assessed three months postpartum. Logistic regression analysis was used to assess the role of maternal and obstetric factors in causing postpartum urinary incontinence. This prospective cohort study in 949 pregnant women in Quebec, Canada was nested within a randomised controlled trial of prenatal perineal massage. RESULTS: Postpartum urinary incontinence was increased with prepregnancy incontinence (adjusted odds ratio [adj0R] 6.44, 95% CI 4.15, 9.98), incontinence beginning during pregnancy (adjOR 1.93, 95% CI 1.32, 2.83), and higher prepregnancy body mass index (adjOR 1.07/unit of BMI, 95% CI 1.03,1.11). Caesarean section was highly protective (adjOR 0.27, 95% CI 0.14, 0.50). While there was a trend towards increasing incontinence with forceps delivery (adjOR 1.73, 95% CI 0.96, 3.13) this was not statistically significant. The weight of the baby, episiotomy, the length of the second stage of labour, and epidural analgesia were not predictive of urinary incontinence. Nor was prenatal perineal massage, the randomised controlled trial intervention. When the analysis was limited to women having their first vaginal birth, the same risk factors were important, with similar adjusted odds ratios. CONCLUSIONS: Urinary incontinence during pregnancy is extremely common, affecting over half of pregnant women. Urinary incontinence beginning during pregnancy roughly doubles the likelihood of urinary incontinence at 3 months postpartum, regardless whether delivery is vaginal or by Caesarean section

    Semantics-based information extraction for detecting economic events

    Get PDF
    As today's financial markets are sensitive to breaking news on economic events, accurate and timely automatic identification of events in news items is crucial. Unstructured news items originating from many heterogeneous sources have to be mined in order to extract knowledge useful for guiding decision making processes. Hence, we propose the Semantics-Based Pipeline for Economic Event Detection (SPEED), focusing on extracting financial events from news articles and annotating these with meta-data at a speed that enables real-time use. In our implementation, we use some components of an existing framework as well as new components, e.g., a high-performance Ontology Gazetteer, a Word Group Look-Up component, a Word Sense Disambiguator, and components for detecting economic events. Through their interaction with a domain-specific ontology, our novel, semantically enabled components constitute a feedback loop which fosters future reuse of acquired knowledge in the event detection process
    corecore