447 research outputs found

    Improved Design Tools for Surface Water and Standing Column Well Heat Pump Systems (DE-EE0002961)

    Full text link
    Ground-source heat pump (GSHP) systems are perhaps the most widely used “sustainable” heating and cooling systems, with an estimated 1.7 million installed units with total installed heating capacity on the order of 18 GW. They are widely used in residential, commercial, and institutional buildings. Standing column wells (SCW) are one form of ground heat exchanger that, under the right geological conditions, can provide excellent energy efficiency at a relatively low capital cost. Closed-loop surface water heat pump (SWHP) systems utilize surface water heat exchangers (SWHE) to reject or extract heat from nearby surface water bodies. For building near surface water bodies, these systems also offer a high degree of energy efficiency at a low capital cost. However, there have been few design tools available for properly sizing standing column wells or surface water heat exchangers. Nor have tools for analyzing the energy consumption and supporting economics-based design decisions been available. The main contributions of this project lie in providing new tools that support design and energy analysis. These include a design tool for sizing surface water heat exchangers, a design tool for sizing standing column wells, a new model of surface water heat pump systems implemented in EnergyPlus and a new model of standing column wells implemented in EnergyPlus. These tools will better help engineers design these systems and determine the economic and technical feasibility

    Assessment of blood-brain barrier disruption using dynamic contrast-enhanced MRI. A systematic review

    Get PDF
    AbstractThere is increasing recognition of the importance of blood–brain barrier (BBB) disruption in aging, dementia, stroke and multiple sclerosis in addition to more commonly-studied pathologies such as tumors. Dynamic contrast-enhanced MRI (DCE-MRI) is a method for studying BBB disruption in vivo. We review pathologies studied, scanning protocols and data analysis procedures to determine the range of available methods and their suitability to different pathologies. We systematically review the existing literature up to February 2014, seeking studies that assessed BBB integrity using T1-weighted DCE-MRI techniques in animals and humans in normal or abnormal brain tissues. The literature search provided 70 studies that were eligible for inclusion, involving 417 animals and 1564 human subjects in total. The pathologies most studied are intracranial neoplasms and acute ischemic strokes. There are large variations in the type of DCE-MRI sequence, the imaging protocols and the contrast agents used. Moreover, studies use a variety of different methods for data analysis, mainly based on model-free measurements and on the Patlak and Tofts models. Consequently, estimated KTrans values varied widely. In conclusion, DCE-MRI is shown to provide valuable information in a large variety of applications, ranging from common applications, such as grading of primary brain tumors, to more recent applications, such as assessment of subtle BBB dysfunction in Alzheimer's disease. Further research is required in order to establish consensus-based recommendations for data acquisition and analysis and, hence, improve inter-study comparability and promote wider use of DCE-MRI

    First Observation and Measurement of the Decay K+- -> pi+- e+ e- gamma

    Get PDF
    Using the full data set of the NA48/2 experiment, the decay K+- -> pi+- e+ e- gamma is observed for the first time, selecting 120 candidates with 7.3 +- 1.7 estimated background events. With K+- -> pi+- pi0D as normalisation channel, the branching ratio is determined in a model-independent way to be Br(K+- -> pi+- e+ e- gamma, m_eegamma > 260 MeV/c^2) = (1.19 +- 0.12_stat +- 0.04_syst) x 10^-8. This measured value and the spectrum of the e+ e- gamma invariant mass allow a comparison with predictions of Chiral Perturbation Theory.Comment: 13 pages, 3 figures. Accepted for publication in Phys.Lett.

    Empirical parameterization of the K+- -> pi+- pi0 pi0 decay Dalitz plot

    Get PDF
    As first observed by the NA48/2 experiment at the CERN SPS, the \p0p0 invariant mass (M00) distribution from \kcnn decay shows a cusp-like anomaly at M00=2m+, where m+ is the charged pion mass. An analysis to extract the pi pi scattering lengths in the isospin I=0 and I=2 states, a0 and a2, respectively, has been recently reported. In the present work the Dalitz plot of this decay is fitted to a new empirical parameterization suitable for practical purposes, such as Monte Carlo simulations of K+- -> pi+- pi0 pi0 decays.Comment: 9 pages, 3 figures

    Turn an Ear to Hear: How Hearing-Impaired Listeners Can Exploit Head Orientation to Enhance Their Speech Intelligibility in Noisy Social Settings

    Get PDF
    Turning an ear toward the talker can enhance spatial release from masking. Here, with their head free, listeners attended to speech at a gradually diminishing signal-to-noise ratio and with the noise source azimuthally separated from the speech source by 180° or 90°. Young normal-hearing adult listeners spontaneously turned an ear toward the speech source in 64% of audio-only trials, but a visible talker’s face or cochlear implant (CI) use significantly reduced this head-turn behavior. All listener groups made more head movements once instructed to explore the potential benefit of head turns and followed the speech to lower signal-to-noise ratios. Unilateral CI users improved the most. In a virtual restaurant simulation with nine interfering noises or voices, hearing-impaired listeners and simulated bilateral CI users typically obtained a 1 to 3 dB head-orientation benefit from a 30° head turn away from the talker. In diffuse interference environments, the advice to U.K. CI users from many CI professionals and the communication guidance available on the Internet most often advise the CI user to face the talker head on. However, CI users would benefit from guidelines that recommend they look sidelong at the talker with their better hearing or implanted ear oriented toward the talker

    Search for direct CP-violation in K+- --> pi+-pi0pi0 decays

    Get PDF
    A search for direct CP-violation in K+- --> pi+-pi0pi0 decays based on 47.14 million events has been performed by the NA48/2 experiment at the CERN SPS. The asymmetry in the Dalitz plot linear slopes A_g=(g^+ - g^-)/(g^+ + g^-) is measured to be A_g=(1.8 +- 2.6).10^{-4}. The design of the experiment and the method of analysis provide good control of instrumental charge asymmetries in this measurement. The precision of the result is limited by statistics and is almost one order of magnitude better than that of previous measurements by other experiments.Comment: 14 page

    Clarity-2021 challenges : machine learning challenges for advancing hearing aid processing

    Get PDF
    In recent years, rapid advances in speech technology have been made possible by machine learning challenges such as CHiME, REVERB, Blizzard, and Hurricane. In the Clarity project, the machine learning approach is applied to the problem of hearing aid processing of speech-in-noise, where current technology in enhancing the speech signal for the hearing aid wearer is often ineffective. The scenario is a (simulated) cuboid-shaped living room in which there is a single listener, a single target speaker and a single interferer, which is either a competing talker or domestic noise. All sources are static, the target is always within ±30◦ azimuth of the listener and at the same elevation, and the interferer is an omnidirectional point source at the same elevation. The target speech comes from an open source 40- speaker British English speech database collected for this purpose. This paper provides a baseline description of the round one Clarity challenges for both enhancement (CEC1) and prediction (CPC1). To the authors’ knowledge, these are the first machine learning challenges to consider the problem of hearing aid speech signal processin

    Evaluation of a method for enhancing interaural level differences at low frequencies.

    Get PDF
    A method (called binaural enhancement) for enhancing interaural level differences at low frequencies, based on estimates of interaural time differences, was developed and evaluated. Five conditions were compared, all using simulated hearing-aid processing: (1) Linear amplification with frequency-response shaping; (2) binaural enhancement combined with linear amplification and frequency-response shaping; (3) slow-acting four-channel amplitude compression with independent compression at the two ears (AGC4CH); (4) binaural enhancement combined with four-channel compression (BE-AGC4CH); and (5) four-channel compression but with the compression gains synchronized across ears. Ten hearing-impaired listeners were tested, and gains and compression ratios for each listener were set to match targets prescribed by the CAM2 fitting method. Stimuli were presented via headphones, using virtualization methods to simulate listening in a moderately reverberant room. The intelligibility of speech at ±60° azimuth in the presence of competing speech on the opposite side of the head at ±60° azimuth was not affected by the binaural enhancement processing. Sound localization was significantly better for condition BE-AGC4CH than for condition AGC4CH for a sentence, but not for broadband noise, lowpass noise, or lowpass amplitude-modulated noise. The results suggest that the binaural enhancement processing can improve localization for sounds with distinct envelope fluctuations
    corecore