368 research outputs found

    Electric fields produced by electron irradiation of insulators in a low vacuum environment

    Full text link
    We report on the properties of electric fields generated as a result of electron irradiation of dielectrics in a low vacuum scanning electron microscope. Individual field components produced by (i) ionized gas molecules located outside the sample surface and (ii) subsurface trapped charge were detected by measurements of changes in (i) primary electron landing energy and (ii) secondary electron (SE) emission current, respectively. The results provide experimental evidence for a recently proposed model of field-enhanced SE emission from electron irradiated insulators in a low vacuum environment [Toth et al., J. Appl. Phys. 91, 4479 (2002)]. Errors introduced into x-ray microanalysis by the electric fields generated by ionized gas molecules can be alleviated by minimizing the steady state ion concentration by the provision of efficient ion neutralization routes. It is demonstrated how this can be achieved using simple sample-electrode geometries. © 2002 American Institute of Physics. © 2002 American Institute of Physics

    Ultra-low pressure hydrocephalic state in NPH: benefits of therapeutic siphoning with adjustable anti-gravity valves

    Get PDF
    Background: Idiopathic normal-pressure hydrocephalus (NPH) is a condition of the elderly treated by ventriculoperitoneal shunt (VP) insertion. A subset of NPH patients respond only temporarily to shunt insertion despite low valve opening pressure. This study aims to describe our experience of patients who benefit from further CSF drainage by adding adjustable antigravity valves and draining CSF at ultra-low pressure. Methods: Single-centre retrospective case series of patients undergoing shunt valve revision from an adjustable differential pressure valve with fixed antigravity unit to a system incorporating an adjustable gravitational valve (Miethke proSA). Patients were screened from a database of NPH patients undergoing CSF diversion over 10 consecutive years (April 2008–April 2018). Clinical records were retrospectively reviewed for interventions and clinical outcomes. Results Nineteen (10F:9M) patients underwent elective VP shunt revision to a system incorporating an adjustable gravitational valve. Mean age 77.1 ± 7.1 years (mean ± SD). Eleven patients (58%) showed significant improvement in walking speed following shunt revision. Fourteen patients/carers (74%) reported subjective improvements in symptoms following shunt revision. Conclusions: Patients presenting symptoms relapse following VP shunting may represent a group of patients with ultra-low-pressure hydrocephalus, for whom further CSF drainage may lead to an improvement in symptoms. These cases may benefit from shunt revision with an adjustable gravitational valve, adjustment of which can lead to controlled siphoning of CSF and drain CSF despite ultra-low CSF pressure

    A comparison of standard and high dose adenosine protocols in routine vasodilator stress cardiovascular magnetic resonance: dosage affects hyperaemic myocardial blood flow in patients with severe left ventricular systolic impairment

    Get PDF
    Background: Adenosine stress perfusion cardiovascular magnetic resonance (CMR) is commonly used in the assessment of patients with suspected ischaemia. Accepted protocols recommend administration of adenosine at a dose of 140 µg/kg/min increased up to 210 µg/kg/min if required. Conventionally, adequate stress has been assessed using change in heart rate, however, recent studies have suggested that these peripheral measurements may not reflect hyperaemia and can be blunted, in particular, in patients with heart failure. This study looked to compare stress myocardial blood flow (MBF) and haemodynamic response with different dosing regimens of adenosine during stress perfusion CMR in patients and healthy controls. Methods: 20 healthy adult subjects were recruited as controls to compare 3 adenosine perfusion protocols: standard dose (140 µg/kg/min for 4 min), high dose (210 µg/kg/min for 4 min) and long dose (140 µg/kg/min for 8 min). 60 patients with either known or suspected coronary artery disease (CAD) or with heart failure and different degrees of left ventricular (LV) dysfunction underwent adenosine stress with standard and high dose adenosine within the same scan. All studies were carried out on a 3 T CMR scanner. Quantitative global myocardial perfusion and haemodynamic response were compared between doses. Results: In healthy controls, no significant difference was seen in stress MBF between the 3 protocols. In patients with known or suspected CAD, and those with heart failure and mild systolic impairment (LV ejection fraction (LVEF) ≥ 40%) no significant difference was seen in stress MBF between standard and high dose adenosine. In those with LVEF < 40%, there was a significantly higher stress MBF following high dose adenosine compared to standard dose (1.33 ± 0.46 vs 1.10 ± 0.47 ml/g/min, p = 0.004). Non-responders to standard dose adenosine (defined by an increase in heart rate (HR) < 10 bpm) had a significantly higher stress HR following high dose (75 ± 12 vs 70 ± 14 bpm, p = 0.034), but showed no significant difference in stress MBF. Conclusions: Increasing adenosine dose from 140 to 210 µg/kg/min leads to increased stress MBF in patients with significantly impaired LV systolic function. Adenosine dose in clinical perfusion assessment may need to be increased in these patients

    Exercise cardiovascular magnetic resonance: feasibility and development of biventricular function and great vessel flow assessment, during continuous exercise accelerated by Compressed SENSE: preliminary results in healthy volunteers

    Get PDF
    Purpose Exercise cardiovascular magnetic resonance (Ex-CMR) typically requires complex post-processing or transient exercise cessation, decreasing clinical utility. We aimed to demonstrate the feasibility of assessing biventricular volumes and great vessel flow during continuous in-scanner Ex-CMR, using vendor provided Compressed SENSE (C-SENSE) sequences and commercial analysis software (Cvi42). Methods 12 healthy volunteers (8-male, age: 35 ± 9 years) underwent continuous supine cycle ergometer (Lode-BV) Ex-CMR (1.5T Philips, Ingenia). Free-breathing, respiratory navigated C-SENSE short-axis cines and aortic/pulmonary phase contrast magnetic resonance (PCMR) sequences were validated against clinical sequences at rest and used during low and moderate intensity Ex-CMR. Optimal PCMR C-SENSE acceleration, C-SENSE-3 (CS3) vs C-SENSE-6 (CS6), was further investigated by image quality scoring. Intra-and inter-operator reproducibility of biventricular and flow indices was performed. Results All CS3 PCMR image quality scores were superior (p  0.93). During Ex-CMR, biventricular end-diastolic volumes (EDV) remained unchanged, except right-ventricular EDV decreasing at moderate exercise. Biventricular ejection-fractions increased at each stage. Exercise biventricular cine and PCMR stroke volumes correlated very strongly (r ≥ 0.9), demonstrating internal validity. Intra-observer reproducibility was excellent, co-efficient of variance (COV) < 10%. Inter-observer reproducibility was excellent, except for resting right-ventricular, and exercise bi-ventricular end-systolic volumes which were good (COV 10–20%). Conclusion Biventricular function, aortic and pulmonary flow assessment during continuous Ex-CMR using CS3 sequences is feasible, reproducible and analysable using commercially available software

    Intracranial pressure in patients with papilloedema

    Get PDF
    OBJECTIVES: Papilloedema is a clinical manifestation of chronically raised intracranial pressure (ICP), often seen in idiopathic intracranial hypertension (IIH). However, the extent of intracranial hypertension required to produce papilloedema is not known. We compare ICP values in IIH patients who developed papilloedema and those who did not. We aim to identify a pathological ICP threshold predictive of the development of papilloedema in IIH patients. MATERIALS AND METHODS: Single-centre cohort of IIH patients (2006-2016) who underwent 24-hour ICP monitoring (ICPM) and ophthalmology assessments, prior to intervention. Papilloedema was graded according to the Frisén scale. An unpaired t-test compared 24-hour ICPM between papilloedema and no-papilloedema groups. Fisher's exact test was used to determine predictive value of ICP. RESULTS: Thirty-six patients with IIH (35 F: 1M), mean age 32.5 ± 9.49 years (mean ± SD) were included. Patients with papilloedema had a mean median 24-hour ICP of 10.4 ± 5.32 mm Hg (n = 25), significantly higher than the group without papilloedema 6.31 ± 3.30 mm Hg (n = 11) (P < .05). The papilloedema group were exposed to higher pressures (10 mm Hg) for 30 minutes or more. Using 24-hour median ICP of 10 mm Hg as a minimum cut-off predictive value gives a specificity = 91%, sensitivity = 48%, PPV = 92% and NPV = 44% of detecting papilloedema. CONCLUSIONS: A 24-hour ICP of 10 mmHg or more is a good predictor for papilloedema and reflects a pathological threshold. The range varied widely suggesting papilloedema can occur at even lower pressures. These results are consistent with emerging evidence suggest that pathologically "high" 24 hours ICP is lower than previously quoted

    Insight Into Myocardial Microstructure of Athletes and Hypertrophic Cardiomyopathy Patients Using Diffusion Tensor Imaging

    Get PDF
    Background Hypertrophic cardiomyopathy (HCM) remains the commonest cause of sudden cardiac death among young athletes. Differentiating between physiologically adaptive left ventricular (LV) hypertrophy observed in athletes' hearts and pathological HCM remains challenging. By quantifying the diffusion of water molecules, diffusion tensor imaging (DTI) MRI allows voxelwise characterization of myocardial microstructure. Purpose To explore microstructural differences between healthy volunteers, athletes, and HCM patients using DTI. Study Type Prospective cohort. Population Twenty healthy volunteers, 20 athletes, and 20 HCM patients. Field Strength/Sequence 3T/DTI spin echo. Assessment In‐house MatLab software was used to derive mean diffusivity (MD) and fractional anisotropy (FA) as markers of amplitude and anisotropy of the diffusion of water molecules, and secondary eigenvector angles (E2A)—reflecting the orientations of laminar sheetlets. Statistical Tests Independent samples t‐tests were used to detect statistical significance between any two cohorts. Analysis of variance was utilized for detecting the statistical difference between the three cohorts. Statistical tests were two‐tailed. A result was considered statistically significant at P ≤ 0.05. Results DTI markers were significantly different between HCM, athletes, and volunteers. HCM patients had significantly higher global MD and E2A, and significantly lower FA than athletes and volunteers. (MDHCM = 1.52 ± 0.06 × 10−3 mm2/s, MDAthletes = 1.49 ± 0.03 × 10−3 mm2/s, MDvolunteers = 1.47 ± 0.02 × 10−3 mm2/s, P < 0.05; E2AHCM = 58.8 ± 4°, E2Aathletes = 47 ± 5°, E2Avolunteers = 38.5 ± 7°, P < 0.05; FAHCM = 0.30 ± 0.02, FAAthletes = 0.35 ± 0.02, FAvolunteers = 0.36 ± 0.03, P < 0.05). HCM patients had significantly higher E2A in their thickest segments compared to the remote (E2Athickest = 66.8 ± 7, E2Aremote = 51.2 ± 9, P < 0.05). Data Conclusion DTI depicts an increase in amplitude and isotropy of diffusion in the myocardium of HCM compared to athletes and volunteers as reflected by increased MD and decreased FA values. While significantly higher E2A values in HCM and athletes reflect steeper configurations of the myocardial sheetlets than in volunteers, HCM patients demonstrated an eccentric rise in E2A in their thickest segments, while athletes demonstrated a concentric rise. Further studies are required to determine the diagnostic capabilities of DTI. Evidence Level 1 Technical Efficacy Stage

    Local recurrence and distant metastases 18 years after resection of the greater omentum hemangiopericytoma

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Hemangiopericytoma occurs with increasing frequency in 5<sup>th </sup>decade of life and has prediction for retroperitoneum and extremities. A case of a local recurrence and metastases of hemangiopericytoma is described.</p> <p>Case presentation</p> <p>Recurrence of hemangiopericytoma in the greater omentum and the jejunal mesentery as well as metastases in the retroperitoneal space were diagnosed in a 61-year-old patient who had a hemangiopericytoma of the greater omentum excised 18 years before.</p> <p>Conclusion</p> <p>Because of the rarity of this disease and its typical clinical course associated with late recurrence and metastases, the authors decided to present this case emphasizing the necessity of systematic oncological follow-up after the end of treatment.</p

    A comparison of standard and high dose adenosine protocols in routine vasodilator stress cardiovascular magnetic resonance: dosage affects hyperaemic myocardial blood flow in patients with severe left ventricular systolic impairment

    Get PDF
    Background Adenosine stress perfusion cardiovascular magnetic resonance (CMR) is commonly used in the assessment of patients with suspected ischaemia. Accepted protocols recommend administration of adenosine at a dose of 140 µg/kg/min increased up to 210 µg/kg/min if required. Conventionally, adequate stress has been assessed using change in heart rate, however, recent studies have suggested that these peripheral measurements may not reflect hyperaemia and can be blunted, in particular, in patients with heart failure. This study looked to compare stress myocardial blood flow (MBF) and haemodynamic response with different dosing regimens of adenosine during stress perfusion CMR in patients and healthy controls. Methods 20 healthy adult subjects were recruited as controls to compare 3 adenosine perfusion protocols: standard dose (140 µg/kg/min for 4 min), high dose (210 µg/kg/min for 4 min) and long dose (140 µg/kg/min for 8 min). 60 patients with either known or suspected coronary artery disease (CAD) or with heart failure and different degrees of left ventricular (LV) dysfunction underwent adenosine stress with standard and high dose adenosine within the same scan. All studies were carried out on a 3 T CMR scanner. Quantitative global myocardial perfusion and haemodynamic response were compared between doses. Results In healthy controls, no significant difference was seen in stress MBF between the 3 protocols. In patients with known or suspected CAD, and those with heart failure and mild systolic impairment (LV ejection fraction (LVEF) ≥ 40%) no significant difference was seen in stress MBF between standard and high dose adenosine. In those with LVEF < 40%, there was a significantly higher stress MBF following high dose adenosine compared to standard dose (1.33 ± 0.46 vs 1.10 ± 0.47 ml/g/min, p = 0.004). Non-responders to standard dose adenosine (defined by an increase in heart rate (HR) < 10 bpm) had a significantly higher stress HR following high dose (75 ± 12 vs 70 ± 14 bpm, p = 0.034), but showed no significant difference in stress MBF. Conclusions Increasing adenosine dose from 140 to 210 µg/kg/min leads to increased stress MBF in patients with significantly impaired LV systolic function. Adenosine dose in clinical perfusion assessment may need to be increased in these patients

    Sequentially based analysis versus image based analysis of Intima Media Thickness in common carotid arteries studies - Do major IMT studies underestimate the true relations for cardio- and cerebrovascular risk?

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Image-based B-mode ultrasound has gained popularity in major studies as a non-invasive method of measuring cardio- and cerebrovascular risk factors. However, none of the major studies appears to have paid sufficient attention to the variation in end diastolic wall process. By using sequentially based analyses (SBA) of Intima-Media Thickness (IMT), the general purpose of this study was to show that the current image based (ECG tracked) analysis (IBA) has some major variations and might underestimate the true relations for cardiovascular events and stroke for IMT measurement.</p> <p>Method</p> <p>The study group consisted of 2500 healthy male subjects aged between 35 to 55 years. 4 sequences (300 images) were analyzed per subject. 750,000 images were analysed throughout the course of this study.</p> <p>Results</p> <p>IBA showed significantly lower mean, maximal, and minimal values for IMT in CCA than for SBA. The correlation analysis between IBA and SBA with the cardio- and cerebrovascular risk factors showed a higher correlation of SBA for all risk factors. The Pearson coefficient was 0.81, p < 0.01, for SBA versus Framingham CHD risk level (FCRL) and 0.49, p = 0.01, for IBA versus FCRL.</p> <p>Conclusion</p> <p>IBA did not measure the true maximal values of the IMT in this study. Together with the correlation analysis, this indicates that IBA might underestimate the true relations for IMT and risk factors.</p
    corecore