4,191 research outputs found

    Large deployable antenna program. Phase 1: Technology assessment and mission architecture

    Get PDF
    The program was initiated to investigate the availability of critical large deployable antenna technologies which would enable microwave remote sensing missions from geostationary orbits as required for Mission to Planet Earth. Program goals for the large antenna were: 40-meter diameter, offset-fed paraboloid, and surface precision of 0.1 mm rms. Phase 1 goals were: to review the state-of-the-art for large, precise, wide-scanning radiometers up to 60 GHz; to assess critical technologies necessary for selected concepts; to develop mission architecture for these concepts; and to evaluate generic technologies to support the large deployable reflectors necessary for these missions. Selected results of the study show that deployable reflectors using furlable segments are limited by surface precision goals to 12 meters in diameter, current launch vehicles can place in geostationary only a 20-meter class antenna, and conceptual designs using stiff reflectors are possible with areal densities of 2.4 deg/sq m

    Implementation of repeat HIV testing during pregnancy in Kenya: a qualitative study.

    Get PDF
    BackgroundRepeat HIV testing in late pregnancy has the potential to decrease rates of mother-to-child transmission of HIV by identifying mothers who seroconvert after having tested negative for HIV in early pregnancy. Despite being national policy in Kenya, the available data suggest that implementation rates are low.MethodsWe conducted 20 in-depth semi-structured interviews with healthcare providers and managers to explore barriers and enablers to implementation of repeat HIV testing guidelines for pregnant women. Participants were from the Nyanza region of Kenya and were purposively selected to provide variation in socio-demographics and job characteristics. Interview transcripts were coded and analyzed in Dedoose software using a thematic analysis approach. Four themes were identified a priori using Ferlie and Shortell's Framework for Change and additional themes were allowed to emerge from the data.ResultsParticipants identified barriers and enablers at the client, provider, facility, and health system levels. Key barriers at the client level from the perspective of providers included late initial presentation to antenatal care and low proportions of women completing the recommended four antenatal visits. Barriers to offering repeat HIV testing for providers included heavy workloads, time limitations, and failing to remember to check for retest eligibility. At the facility level, inconsistent volume of clients and lack of space required for confidential HIV retesting were cited as barriers. Finally, at the health system level, there were challenges relating to the HIV test kit supply chain and the design of nationally standardized antenatal patient registers. Enablers to improving the implementation of repeat HIV testing included client dissemination of the benefits of antenatal care through word-of-mouth, provider cooperation and task shifting, and it was suggested that use of an electronic health record system could provide automatic reminders for retest eligibility.ConclusionsThis study highlights some important barriers to improving HIV retesting rates among pregnant women who attend antenatal clinics in the Nyanza region of Kenya at the client, provider, facility, and health system levels. To successfully implement Kenya's national repeat HIV testing guidelines during pregnancy, it is essential that these barriers be addressed and enablers capitalized on through a multi-faceted intervention program

    2D cognitive optical data processing with phase change materials

    No full text
    We demonstrate high-density, multi-level crystallization of a Ge2Sb2Te5 thin film using tightly focused femtosecond laser pulses. The optical reflectivity in each distinct phase states level is characterized for applications in ultra-fast cognitive parallel data processing

    Generation and delivery device for ozone gas and ozone dissolved in water

    Get PDF
    The present invention provides an ozone generation and delivery system that lends itself to small scale applications and requires very low maintenance. The system includes an anode reservoir and a cathode phase separator each having a hydrophobic membrane to allow phase separation of produced gases from water. The system may be configured to operate passively with no moving parts or in a self-pressurizing manner with the inclusion of a pressure controlling device or valve in the gas outlet of the anode reservoir. The hydrogen gas, ozone gas and water containing ozone may be delivered under pressure

    Robotic partial nephrectomy for posterior tumors through a retroperitoneal approach offers decreased length of stay compared with the transperitoneal approach: A propensity-matched analysis

    Get PDF
    INTRODUCTION: We sought to compare surgical outcomes between transperitoneal and retroperitoneal robotic partial nephrectomy (RPN) for posterior tumors. PATIENTS AND METHODS: Using our multi-institutional RPN database, we reviewed 610 consecutive cases for posterior renal masses treated between 2007 and 2015. Primary outcomes were complications, operative time, length of stay (LOS), surgical margin status, and estimated glomerular filtration rate (eGFR) preservation. Secondary outcomes were estimated blood loss, warm ischemia time (WIT), disease recurrence, and disease-specific mortality. Due to significant differences in treatment year and tumor size between approaches, retroperitoneal cases were matched 1:4 to transperitoneal cases based on propensity scores using the greedy algorithm. Outcomes were compared between approaches using the chi-square and Mann-Whitney U tests. RESULTS: After matching, 296 transperitoneal and 74 retroperitoneal cases were available for analysis, and matched groups were well balanced in terms of treatment year, age, gender, race, American Society of Anesthesiologists physical status classification (ASA) score, body mass index, tumor laterality, tumor size, R.E.N.A.L. (radius, exophytic/endophytic properties, nearness of tumor to the collecting system or sinus, anterior/posterior, location relative to polar lines) score, and hilar location. Compared with transperitoneal, the retroperitoneal approach was associated with significantly shorter mean LOS (2.2 vs 2.6 days, p = 0.01), but longer mean WIT (21 vs 19 minutes, p = 0.01). Intraoperative (p = 0.35) and postoperative complications (p = 0.65), operative time (p = 0.93), positive margins (p = 1.0), and latest eGFR preservation (p = 0.25) were not significantly different between approaches. No differences were detected in the other outcomes. CONCLUSIONS: Among high-volume surgeons, transperitoneal and retroperitoneal RPN achieved similar outcomes for posterior renal masses, although with slight differences in LOS and WIT. Retroperitoneal RPN may be an effective option for the treatment of certain small posterior renal masses

    Benefits of Application of Advanced Technologies for a Neptune Orbiter, Atmospheric Probes and Triton Lander

    Get PDF
    Missions with planned launch dates several years from today pose significant design challenges in properly accounting for technology advances that may occur in the time leading up to actual spacecraft design, build, test and launch. Conceptual mission and spacecraft designs that rely solely on off the shelf technology will result in conservative estimates that may not be attractive or truly representative of the mission as it actually will be designed and built. This past summer, as part of one of NASA s Vision Mission Studies, a group of students at the Laboratory for Spacecraft and Mission Design (LSMD) have developed and analyzed different Neptune mission baselines, and determined the benefits of various assumed technology improvements. The baseline mission uses either a chemical propulsion system or a solar-electric system. Insertion into orbit around Neptune is achieved by means of aerocapture. Neptune s large moon Triton is used as a tour engine. With these technologies a comprehensive Cassini-class investigation of the Neptune system is possible. Technologies under investigation include the aerocapture heat shield and thermal protection system, both chemical and solar electric propulsion systems, spacecraft power, and energy storage systems

    miR-196b target screen reveals mechanisms maintaining leukemia stemness with therapeutic potential.

    Get PDF
    We have shown that antagomiR inhibition of miRNA miR-21 and miR-196b activity is sufficient to ablate MLL-AF9 leukemia stem cells (LSC) in vivo. Here, we used an shRNA screening approach to mimic miRNA activity on experimentally verified miR-196b targets to identify functionally important and therapeutically relevant pathways downstream of oncogenic miRNA in MLL-r AML. We found Cdkn1b (p27Kip1) is a direct miR-196b target whose repression enhanced an embryonic stem cell–like signature associated with decreased leukemia latency and increased numbers of leukemia stem cells in vivo. Conversely, elevation of p27Kip1 significantly reduced MLL-r leukemia self-renewal, promoted monocytic differentiation of leukemic blasts, and induced cell death. Antagonism of miR-196b activity or pharmacologic inhibition of the Cks1-Skp2–containing SCF E3-ubiquitin ligase complex increased p27Kip1 and inhibited human AML growth. This work illustrates that understanding oncogenic miRNA target pathways can identify actionable targets in leukemia

    Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device and Medical Management in Ambulatory Heart Failure Patients The ROADMAP Study 2-Year Results

    Get PDF
    OBJECTIVES The authors sought to provide the pre-specified primary endpoint of the ROADMAP (Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device and Medical Management in Ambulatory Heart Failure Patients) trial at 2 years. BACKGROUND The ROADMAP trial was a prospective nonrandomized observational study of 200 patients (97 with a left ventricular assist device [LVAD], 103 on optimal medical management [OMM]) that showed that survival with improved functional status at 1 year was better with LVADs compared with OMM in a patient population of ambulatory New York Heart Association functional class IIIb/IV patients. METHODS The primary composite endpoint was survival on original therapy with improvement in 6-min walk distance \u3e= 75 m. RESULTS Patients receiving LVAD versus OMM had lower baseline health-related quality of life, reduced Seattle Heart Failure Model 1-year survival (78% vs. 84%; p = 0.012), and were predominantly INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) profile 4 (65% vs. 34%; p \u3c 0.001) versus profiles 5 to 7. More LVAD patients met the primary endpoint at 2 years: 30% LVAD versus 12% OMM (odds ratio: 3.2 [95% confidence interval: 1.3 to 7.7]; p = 0.012). Survival as treated on original therapy at 2 years was greater for LVAD versus OMM (70 +/- 5% vs. 41 +/- 5%; p \u3c 0.001), but there was no difference in intent-to-treat survival (70 +/- 5% vs. 63 +/- 5%; p = 0.307). In the OMM arm, 23 of 103 (22%) received delayed LVADs (18 within 12 months; 5 from 12 to 24 months). LVAD adverse events declined after year 1 for bleeding (primarily gastrointestinal) and arrhythmias. CONCLUSIONS Survival on original therapy with improvement in 6-min walk distance was superior with LVAD compared with OMM at 2 years. Reduction in key adverse events beyond 1 year was observed in the LVAD group. The ROADMAP trial provides risk-benefit information to guide patient- and physician-shared decision making for elective LVAD therapy as a treatment for heart failure. (Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device and Medical Management in Ambulatory Heart Failure Patients [ROADMAP]; NCT01452802
    corecore