    The Electrically Evoked Compound Action Potential: From Laboratory to Clinic

    Get PDF
    The electrically evoked compound action potential (eCAP) represents the synchronous firing of a population of electrically stimulated auditory nerve fibers. It can be directly recorded on a surgically exposed nerve trunk in animals or from an intra-cochlear electrode of a cochlear implant. In the past two decades, the eCAP has been widely recorded in both animals and clinical patient populations using different testing paradigms. This paper provides an overview of recording methodologies and response characteristics of the eCAP, as well as its potential applications in research and clinical situations. Relevant studies are reviewed and implications for clinicians are discussed

    Effects of cochlear implantation on binaural hearing in adults with unilateral hearing loss

    Get PDF
    A FDA clinical trial was carried out to evaluate the potential benefit of cochlear implant (CI) use for adults with unilateral moderate-to-profound sensorineural hearing loss. Subjects were 20 adults with moderate-to-profound unilateral sensorineural hearing loss and normal or near-normal hearing on the other side. A MED-EL standard electrode was implanted in the impaired ear. Outcome measures included: (a) sound localization on the horizontal plane (11 positions, −90° to 90°), (b) word recognition in quiet with the CI alone, and (c) masked sentence recognition with the target at 0° and the masker at −90°, 0°, or 90°. This battery was completed preoperatively and at 1, 3, 6, 9, and 12 months after CI activation. Normative data were also collected for 20 age-matched control subjects with normal or near-normal hearing bilaterally. The CI improved localization accuracy and reduced side bias. Word recognition with the CI alone was similar to performance of traditional CI recipients. The CI improved masked sentence recognition when the masker was presented from the front or from the side of normal or near-normal hearing. The binaural benefits observed with the CI increased between the 1- and 3-month intervals but appeared stable thereafter. In contrast to previous reports on localization and speech perception in patients with unilateral sensorineural hearing loss, CI benefits were consistently observed across individual subjects, and performance was at asymptote by the 3-month test interval. Cochlear implant settings, consistent CI use, and short duration of deafness could play a role in this result

    Auditory discrimination: The relationship between psychophysical and electrophysiological measures

    Get PDF
    This study aimed to 1) investigate the relationship between the acoustic change complex (ACC) and perceptual measures of frequency and intensity discrimination, and gap detection; and 2) examine the effects of acoustic change on the amplitudes and latencies of the ACC

    Electrically Evoked Auditory Event-Related Responses in Patients with Auditory Brainstem Implants: Morphological Characteristics, Test–Retest Reliability, Effects of Stimulation Level, and Association with Auditory Detection

    Get PDF
    This study aimed to 1) characterize morphological characteristics of the electrically-evoked cortical auditory event-related potentials (eERP) and explore the potential association between onset eERP morphology and auditory vs non-auditory stimulation; 2) assess test-retest reliability of onset eERPs; 3) investigate effects of stimulation level on onset eERPs; and 4) explore the feasibility of using the onset eERP to estimate the lowest stimulation level that can be detected for individual stimulating electrodes in patients with auditory brainstem implants (ABIs)

    Cochlear Implant–Evoked Cortical Activation in Children With Cochlear Nerve Deficiency

    Get PDF
    To report the results of cochlear implant-elicited cortical auditory evoked potentials (eCAEP) in children with cochlear nerve deficiency (CND)

    Intraoperative electrocochleographic characteristics of auditory neuropathy spectrum disorder in cochlear implant subjects

    Get PDF
    Auditory neuropathy spectrum disorder (ANSD) is characterized by an apparent discrepancy between measures of cochlear and neural function based on auditory brainstem response (ABR) testing. Clinical indicators of ANSD are a present cochlear microphonic (CM) with small or absent wave V. Many identified ANSD patients have speech impairment severe enough that cochlear implantation (CI) is indicated. To better understand the cochleae identified with ANSD that lead to a CI, we performed intraoperative round window electrocochleography (ECochG) to tone bursts in children (n = 167) and adults (n = 163). Magnitudes of the responses to tones of different frequencies were summed to measure the “total response” (ECochG-TR), a metric often dominated by hair cell activity, and auditory nerve activity was estimated visually from the compound action potential (CAP) and auditory nerve neurophonic (ANN) as a ranked “Nerve Score”. Subjects identified as ANSD (45 ears in children, 3 in adults) had higher values of ECochG-TR than adult and pediatric subjects also receiving CIs not identified as ANSD. However, nerve scores of the ANSD group were similar to the other cohorts, although dominated by the ANN to low frequencies more than in the non-ANSD groups. To high frequencies, the common morphology of ANSD cases was a large CM and summating potential, and small or absent CAP. Common morphologies in other groups were either only a CM, or a combination of CM and CAP. These results indicate that responses to high frequencies, derived primarily from hair cells, are the main source of the CM used to evaluate ANSD in the clinical setting. However, the clinical tests do not capture the wide range of neural activity seen to low frequency sounds

    Assessment of cochlear synaptopathy by electrocochleography to low frequencies in a preclinical model and human subjects

    Get PDF
    Cochlear synaptopathy is the loss of synapses between the inner hair cells and the auditory nerve despite survival of sensory hair cells. The findings of extensive cochlear synaptopathy in animals after moderate noise exposures challenged the long-held view that hair cells are the cochlear elements most sensitive to insults that lead to hearing loss. However, cochlear synaptopathy has been difficult to identify in humans. We applied novel algorithms to determine hair cell and neural contributions to electrocochleographic (ECochG) recordings from the round window of animal and human subjects. Gerbils with normal hearing provided training and test sets for a deep learning algorithm to detect the presence of neural responses to low frequency sounds, and an analytic model was used to quantify the proportion of neural and hair cell contributions to the ECochG response. The capacity to detect cochlear synaptopathy was validated in normal hearing and noise-exposed animals by using neurotoxins to reduce or eliminate the neural contributions. When the analytical methods were applied to human surgical subjects with access to the round window, the neural contribution resembled the partial cochlear synaptopathy present after neurotoxin application in animals. This result demonstrates the presence of viable hair cells not connected to auditory nerve fibers in human subjects with substantial hearing loss and indicates that efforts to regenerate nerve fibers may find a ready cochlear substrate for innervation and resumption of function

    Objective Measures of Electrode Discrimination With Electrically Evoked Auditory Change Complex and Speech-Perception Abilities in Children With Auditory Neuropathy Spectrum Disorder

    Get PDF
    This study aimed to 1) determine the sensitivity of the electrically evoked auditory change complex (eACC) to changes in stimulating electrode position; and 2) investigate the association between results of eACC measures and behavioral electrode discrimination and their association with speech-perception performance in pediatric cochlear implant (CI) users who have auditory neuropathy spectrum disorder (ANSD)

    Electrocochleography and cognition are important predictors of speech perception outcomes in noise for cochlear implant recipients

    Get PDF
    Although significant progress has been made in understanding outcomes following cochlear implantation, predicting performance remains a challenge. Duration of hearing loss, age at implantation, and electrode positioning within the cochlea together explain ~ 25% of the variability in speech-perception scores in quiet using the cochlear implant (CI). Electrocochleography (ECochG) responses, prior to implantation, account for 47% of the variance in the same speech-perception measures. No study to date has explored CI performance in noise, a more realistic measure of natural listening. This study aimed to (1) validate ECochG total response (ECochG-TR) as a predictor of performance in quiet and (2) evaluate whether ECochG-TR explained variability in noise performance. Thirty-five adult CI recipients were enrolled with outcomes assessed at 3-months post-implantation. The results confirm previous studies showing a strong correlation of ECochG-TR with speech-perception in quiet (r = 0.77). ECochG-TR independently explained 34% of the variability in noise performance. Multivariate modeling using ECochG-TR and Montreal Cognitive Assessment (MoCA) scores explained 60% of the variability in speech-perception in noise. Thus, ECochG-TR, a measure of the cochlear substrate prior to implantation, is necessary but not sufficient for explaining performance in noise. Rather, a cognitive measure is also needed to improve prediction of noise performance