2,746 research outputs found
QCALT: a tile calorimeter for KLOE-2 upgrade
The upgrade of the DANE machine layout requires a modification of the
size and position of the inner focusing quadrupoles of KLOE-2 thus asking for
the realization of two new calorimeters covering the quadrupoles area. To
improve the reconstruction of events with photons hitting the
quadrupoles a calorimeter with high efficiency to low energy photons (20-300
MeV), time resolution of less than 1 ns and space resolution of few cm, is
needed. To match these requirements, we are designing a tile calorimeter,
QCALT, where each single tile is readout by mean of SiPM for a total
granularity of 2400 channels. We show first tests of the different calorimeter
components
Pre-Production and Quality Assurance of the Mu2e Calorimeter Silicon Photomultipliers
The Mu2e electromagnetic calorimeter has to provide precise information on
energy, time and position for 100 MeV electrons. It is composed of 1348
un-doped CsI crystals, each coupled to two large area Silicon Photomultipliers
(SiPMs). A modular and custom SiPM layout consisting of a 32 array of
66 mm UV-extended monolithic SiPMs has been developed to fulfill
the Mu2e calorimeter requirements and a pre-production of 150 prototypes has
been procured by three international firms (Hamamatsu, SensL and Advansid). A
detailed quality assurance process has been carried out on this first batch of
photosensors: the breakdown voltage, the gain, the quenching time, the dark
current and the Photon Detection Efficiency (PDE) have been determined for each
monolithic cell of each SiPMs array. One sample for each vendor has been
exposed to a neutron fluency up to 8.5~~10 1 MeV (Si) eq.
n/cm and a linear increase of the dark current up to tens of mA has been
observed. Others 5 samples for each vendor have undergone an accelerated aging
in order to verify a Mean Time To Failure (MTTF) higher than 10
hours.Comment: NDIP 2017 - New Developments In Photodetection, 3-7 July 2017, Tours
(France
Longitudinal uniformity, time performance and irradiation test of pure CsI crystals
To study an alternative to BaF2, as the crystal choice for the Mu2e
calorimeter, thirteen pure CsI crystals from Opto Materials and ISMA producers
have been characterized by determining their light yield (LY) and longitudinal
response uniformity (LRU), when read with a UV extended PMT. The crystals show
a LY of ~ 100 p.e./MeV (~ 150 p.e./MeV) when wrapped with Tyvek and coupled to
the PMT without (with) optical grease. The LRU is well represented by a linear
slope that is on average around -0.6 %/cm. The timing performances of the Opto
Materials crystal, read with a UV extended MPPC, have been evaluated with
minimum ionizing particles. A timing resolution of ~ 330 ps (~ 440 ps) is
achieved when connecting the photosensor to the MPPC with (without) optical
grease. The crystal radiation hardness to a ionization dose has also been
studied for one pure CsI crystal from SICCAS. After exposing it to a dose of
900 Gy, a decrease of 33% in the LY is observed while the LRU remains
unchanged.Comment: Presented at Frontier Detectors for Frontier Physics,13th Pisa
Meeting on Advanced Detectors, 24-30 May 2015 (2 pages, 4 figures
Energy spectra of quasiperiodic systems via information entropy
We study the relationship between the electronic spectrum structure and the
configurational order of one-dimensional quasiperiodic systems. We take the
Fibonacci case as an specific example, but the ideas outlined here may be
useful to accurately describe the energy spectra of general quasiperiodic
systems of technological interest. Our main result concerns the {\em
minimization} of the information entropy as a characteristic feature associated
to quasiperiodic arrangements. This feature is shown to be related to the
ability of quasiperiodic systems to encode more information, in the Shannon
sense, than periodic ones. In the conclusion we comment on interesting
implications of these results on further developments on the issue of
quasiperiodic order.Comment: REVTeX 3.0, 8 pages, 3 figures available on request from FD-A
([email protected]), Phys Rev E submitted, MA/UC3M/02/9
Energy and time resolution for a LYSO matrix prototype of the Mu2e experiment
We have measured the performances of a LYSO crystal matrix prototype tested
with electron and photon beams in the energy range 60450 MeV. This study has
been carried out to determine the achievable energy and time resolutions for
the calorimeter of the Mu2e experiment.Comment: 2 pages, 3 figures, 13th Pisa Meeting on Advanced Detector
Design, status and perspective of the Mu2e crystal calorimeter
The Mu2e experiment at Fermilab will search for the charged lepton flavor
violating process of neutrino-less coherent conversion in the field
of an aluminum nucleus. Mu2e will reach a single event sensitivity of about
that corresponds to four orders of magnitude improvements
with respect to the current best limit. The detector system consists of a straw
tube tracker and a crystal calorimeter made of undoped CsI coupled with Silicon
Photomultipliers. The calorimeter was designed to be operable in a harsh
environment where about 10 krad/year will be delivered in the hottest region
and work in presence of 1 T magnetic field. The calorimeter role is to perform
/e separation to suppress cosmic muons mimiking the signal, while
providing a high level trigger and a seeding the track search in the tracker.
In this paper we present the calorimeter design and the latest RD results.Comment: 4 pages, conference proceeding for a presentation held at TIPP'2017.
To be published on Springer Proceedings in Physic
- …
