73 research outputs found

    Greater effects of high- compared with moderate-intensity interval training on cardio-metabolic variables, blood leptin concentration and ratings of perceived exertion in obese adolescent females

    Get PDF
    This study examined the effects of high- vs. moderate-intensity interval training on cardiovascular fitness, leptin levels and ratings of perceived exertion (RPE) in obese female adolescents. Forty-seven participants were randomly assigned to one of three groups receiving either a 1:1 ratio of 15 s of effort comprising moderate-intensity interval training (MIIT at 80% maximal aerobic speed: MAS) or high-intensity interval training (HIIT at 100% MAS), with matched 15 s recovery at 50% MAS, thrice weekly, or a no-training control group. The HIIT and MIIT groups showed improved (p < 0.05) body mass (BM), BMI Z-score, and percentage of body fat (%BF). Only the HIIT group showed decreased waist circumference (WC) (p = 0.017). The effect of exercise on maximal oxygen uptake (VO2max) was significant (p = 0.019, ES = 0.48 and p = 0.010, ES = 0.57, HIIT and MIIT, respectively). The decrease of rate-pressure product (RPP) (p < 0.05, ES = 0.53 and ES = 0.46, HIIT and MIIT, respectively) followed the positive changes in resting heart rate and blood pressures. Blood glucose, insulin level and the homeostasis model assessment index for insulin decreased (p < 0.05) in both training groups. Significant decreases occurred in blood leptin (p = 0.021, ES = 0.67 and p = 0.011, ES = 0.73) and in RPE (p = 0.001, ES = 0.76 and p = 0.017, ES = 0.57) in HIIT and MIIT, respectively. In the post-intervention period, blood leptin was strongly associated with %BF (p < 0.001) and VO2max (p < 0.01) in the HIIT and MIIT groups, respectively, while RPE was strongly associated with BM (p < 0.01) in the HIIT group. The results suggest that high-intensity interval training may produce more positive effects on health determinants in comparison with the same training mode at a moderate intensity.Ministry of Higher Education, Scientific Research and Technology of Tunisia

    Finite-element-method (FEM) model generation of time-resolved 3D echocardiographic geometry data for mitral-valve volumetry

    Get PDF
    INTRODUCTION: Mitral Valve (MV) 3D structural data can be easily obtained using standard transesophageal echocardiography (TEE) devices but quantitative pre- and intraoperative volume analysis of the MV is presently not feasible in the cardiac operation room (OR). Finite element method (FEM) modelling is necessary to carry out precise and individual volume analysis and in the future will form the basis for simulation of cardiac interventions. METHOD: With the present retrospective pilot study we describe a method to transfer MV geometric data to 3D Slicer 2 software, an open-source medical visualization and analysis software package. A newly developed software program (ROIExtract) allowed selection of a region-of-interest (ROI) from the TEE data and data transformation for use in 3D Slicer. FEM models for quantitative volumetric studies were generated. RESULTS: ROI selection permitted the visualization and calculations required to create a sequence of volume rendered models of the MV allowing time-based visualization of regional deformation. Quantitation of tissue volume, especially important in myxomatous degeneration can be carried out. Rendered volumes are shown in 3D as well as in time-resolved 4D animations. CONCLUSION: The visualization of the segmented MV may significantly enhance clinical interpretation. This method provides an infrastructure for the study of image guided assessment of clinical findings and surgical planning. For complete pre- and intraoperative 3D MV FEM analysis, three input elements are necessary: 1. time-gated, reality-based structural information, 2. continuous MV pressure and 3. instantaneous tissue elastance. The present process makes the first of these elements available. Volume defect analysis is essential to fully understand functional and geometrical dysfunction of but not limited to the valve. 3D Slicer was used for semi-automatic valve border detection and volume-rendering of clinical 3D echocardiographic data. FEM based models were also calculated. METHOD: A Philips/HP Sonos 5500 ultrasound device stores volume data as time-resolved 4D volume data sets. Data sets for three subjects were used. Since 3D Slicer does not process time-resolved data sets, we employed a standard movie maker to animate the individual time-based models and visualizations. Calculation time and model size were minimized. Pressures were also easily available. We speculate that calculation of instantaneous elastance may be possible using instantaneous pressure values and tissue deformation data derived from the animated FEM

    Prediction of peak oxygen uptake in children using submaximal ratings of perceived exertion during treadmill exercise

    Get PDF
    Purpose: This study assessed the utility of the Children’s Effort Rating Table (CERT) and the Eston-Parfitt (EP) Scale in estimating peak oxygen uptake (V• O2peak) in children, during cardiopulmonary exercise testing (CPET) on a treadmill. Methods: Fifty healthy children (n=21 boys; 9.4 ± 0.9 y) completed a continuous, incremental protocol until the attainment of V• O2peak. Oxygen uptake (V• O2) was measured continuously, and Ratings of Perceived Exertion (RPE) were estimated at the end of each exercise stage using the CERT and the EP Scale. Ratings up to- and including RPE 5 and 7, from both the CERT (CERT 5, CERT 7) and EP Scale (EP 5, EP 7), were linearly regressed against the corresponding V• O2, to both maximal RPE (CERT 10, EP 10) and terminal RPE (CERT 9, EP 9). Results: There were no differences between measured- and predicted V• O2peak from CERT 5, CERT 7, EP 5 and EP 7 when extrapolated to either CERT 9 or EP 9 (P &gt; .05). Pearson’s correlations of r = 0.64-0.86 were observed between measured- and predicted V• O2peak, for all perceptual ranges investigated. However, only EP 7 provided a small difference when considering the Standard Error of Estimate, suggesting that the prediction of V• O2peak from EP 7 would be within 10% of measured V• O2peak. Conclusions: Although robust estimates of V• O2peak may be elicited using both the CERT and EP Scale during a single CPET with children, the most accurate estimates of V• O2peak occur when extrapolating from EP 7

    Will the Conscious–Subconscious Pacing Quagmire Help Elucidate the Mechanisms of Self-Paced Exercise? New Opportunities in Dual Process Theory and Process Tracing Methods

    Get PDF
    The extent to which athletic pacing decisions are made consciously or subconsciously is a prevailing issue. In this article we discuss why the one-dimensional conscious–subconscious debate that has reigned in the pacing literature has suppressed our understanding of the multidimensional processes that occur in pacing decisions. How do we make our decisions in real-life competitive situations? What information do we use and how do we respond to opponents? These are questions that need to be explored and better understood, using smartly designed experiments. The paper provides clarity about key conscious, preconscious, subconscious and unconscious concepts, terms that have previously been used in conflicting and confusing ways. The potential of dual process theory in articulating multidimensional aspects of intuitive and deliberative decision-making processes is discussed in the context of athletic pacing along with associated process-tracing research methods. In attempting to refine pacing models and improve training strategies and psychological skills for athletes, the dual-process framework could be used to gain a clearer understanding of (1) the situational conditions for which either intuitive or deliberative decisions are optimal; (2) how intuitive and deliberative decisions are biased by things such as perception, emotion and experience; and (3) the underlying cognitive mechanisms such as memory, attention allocation, problem solving and hypothetical thought

    Respir Res

    Get PDF
    Background: Sexual function is often affected in patients suffering from chronic diseases especially chronic obstructive pulmonary disease (COPD). However, the effect of COPD on sexual satisfaction is underappreciated in clinical practice. The aim of this study is to evaluate the impact of COPD on patient’s sexuality and the explanatory variables of sexual dissatisfaction. Methods: Questionnaires were emailed to participants and they submitted their responses on the Santé Respiratoire France website. Data about sexual well-being (Arizona Sexual Experience Scale, ASEX), Quality of life (VQ11), anxiety, depression (Hospitalized anxiety and depression, HAD) and self-declared COPD grade were collected. Results: Seven hundred and fifty one subjects were included and were characterized as follows: women—51%, mean age—61 years, in a couple—62% and 70%—retired. Every grade of COPD was represented. Out of 751 participants, 301 participants (40%) had no sexual activity and 450 (60%) had sexual activity. From the 450 participants, 60% needed to change their sexual life because of their disease (rhythm, frequency and position). Subjects often used medications to improve sexual performance (43% used short-acting bronchodilator and 13% -specific erectile dysfunction drugs). ASEX questionnaire confirmed patients’ dissatisfaction (diminution of sexual appetite for 68% and sexual desire for 60%) because of breathlessness and fatigue. Eighty one percent of the responders had an altered quality of life (VQ11 mean score 35) and frequent suspected anxiety or depression (HAD mean score 10.8). Ninety percent declared that sexual dysfunction had never been discussed by their doctors, while 36% of patients would have preferred to undergo a specialized consultation. Conclusion: Sexual dysfunction is frequent among COPD patients and leads to an altered well-being, however being a cultural taboo, it remains frequently neglected. Sexual guidance should be a part of patient’s consultations improve quality of sexual life. © 2020, The Author(s)

    Plan de la Baye et de la ville de Rio-Janeiro : [estampe]

    No full text
    Référence bibliographique : Hennin, 738

    Development and performance of a new version of the OASIS coupler, OASIS3-MCT_3.0

    No full text
    OASIS is coupling software developed primarily for use in the climate community. It provides the ability to couple different models with low implementation and performance overhead. OASIS3-MCT is the latest version of OASIS. It includes several improvements compared to OASIS3, including elimination of a separate hub coupler process, parallelization of the coupling communication and run-time grid interpolation, and the ability to easily reuse mapping weight files. OASIS3-MCT_3.0 is the latest release and includes the ability to couple between components running sequentially on the same set of tasks as well as to couple within a single component between different grids or decompositions such as physics, dynamics, and I/O. OASIS3-MCT has been tested with different configurations on up to 32 000 processes, with components running on high-resolution grids with up to 1.5 million grid cells, and with over 10 000 2-D coupling fields. Several new features will be available in OASIS3-MCT_4.0, and some of those are also described
    • …
    corecore