13 research outputs found
Oscillatory Photodynamic Therapy for Choroidal Neovascularization and Central Serous Retinopathy; a Pilot Study
Purpose: To report the preliminary results of oscillatory photodynamic therapy (OPDT) for choroidal neovascularization (CNV) and central serous retinopathy (CSR). Methods: This study included 7 eyes of 6 patients with CSR (2 eyes), idiopathic CNV (2 eyes), CNV due to age-related macular degeneration (AMD) (2 eyes), and peripapillary CNV secondary to presumed ocular histoplasmosis syndrome (1 eye). Intravenous verteporfin (6 mg/m2 body surface area) was infused over 10 minutes followed by oscillating laser (wavelength 689 nm) covering slightly beyond the entire lesion. An Area Centralis lens was applied and laser was delivered (600 mW/cm2 fluence rate and 50 J/cm2 dose). Intravitreal bevacizumab and dexamethasone combination therapy was used with OPDT in 4 eyes with CNV; intravitreal dexamethasone and triamcinolone acetonide were injected in the other eye with CNV. Clinical examination, funduscopy, fluorescein angiography, and optical coherence tomography (OCT) were performed at baseline and after treatment. Results: After mean follow-up of 7.1±5.1 months, visual acuity improved from 0.87±0.69 logMAR (20/160) to 0.60±0.65 logMAR (20/80) (P = 0.027); central foveal thickness decreased from 322±62.1 to 240.7±34.8 microns as measured by OCT (P = 0.018). Fluorescein angiography and OCT demonstrated cessation of vascular leakage, and resolution of hemorrhage and subretinal fluid in all eyes. No adverse events or recurrence were noted. Conclusion: OPDT was effective in treating CNV lesions and CSR. OPDT may be an improvement on standard PDT due to reduced side effects, thermal damage and scarring
Innovative Diagnostic Tools for Ophthalmology in Low-Income Countries
Globally, there are almost 300 million people blind and visually impaired and over 90% live developing countries. The gross disparity in access to ophthalmologists limits the ability to accurately diagnose potentially blinding conditions like cataract, glaucoma, trachoma, uncorrected refractive error and limits timely initiation of medical and surgical treatment. Since 85% of blindness is preventable, bridging this chasm for care is even more critical in preventing needless blindness. Many low-income countries must rely on community health workers, physician assistants, and cataract surgeons for primary eye care. Ophthalmology in low-income countries (LIC) is further challenging due to complexities brought from tropical climates, frail electric grids, poor road and water infrastructure, limited diagnostic capability and limited treatment options. Vision 2020 set the goal of eliminating preventable blindness by 2020 despite formidable obstacles. Innovative technologies are emerging to test visual acuity, correct refractive error quickly and inexpensively, capture retinal images with portable tools, train cataract surgeons using simulators, capitalize on mHealth, access ophthalmic information remotely. These advancements are allowing nonspecialized ophthalmic practitioners to provide low-cost, high impact eye care in resource-limited regions around the world
A Brief Overview of Ophthalmic Ultrasound Imaging
Ultrasound is one of the oldest imaging modalities. Sound waves are emitted into the body, and the returning echoes can be interpreted. It has become widely used because it can easily be done at bedside with a relatively small apparatus and does not expose the patient to any ionizing radiation. While this technique has seen widespread acceptance in other fields such as cardiology or obstetrics and gynecology, the general use in ophthalmology has been somewhat limited. However, recent advancements in ultrasonic arrays can be a powerful tool in the evaluation of ophthalmic pathology. Such systems can quickly generate very high detail images and 3D reconstructions without the need for extensive manual scanning. The application of this technology includes evaluation of traumatic eye injuries; assessing presence and location of an intraocular foreign body; evaluation of intraocular tumors, including small tumors that have not yet caused visual distortion; evaluation of retinal detachment; and evaluation of vascular disease. The goal of this article is to briefly review the history and development of ultrasound and to provide an overview of the most current systems and applications of ultrasound use in ophthalmologic clinical evaluation
Endogenous Endophthalmitis: Etiology and Treatment
This chapter comprehensively covers all aspects of endogenous endophthalmitis from systemic infectious agents, with an emphasis on reported and newer etiologies to broaden the diagnostic and investigative acumen of treating ophthalmic providers. The discussion includes the etiology of metastatic endophthalmitis and diagnostic investigations, including polymerase chain reaction (PCR), for identification of bacterial and viral infections involving the eye in both immunosuppressed in non-immunosuppressed patients. Additionally, we present clinical and diagnostic findings of fungal infections, protozoal infections, and helminthic infections. Pediatric cases are also reported and etiologies described. We discuss both etiology and diagnostic challenges. Current therapeutic modalities and outcomes are reviewed. While no two cases of metastatic endophthalmitis are the same, some similarities may exist that allow us to generalize how to approach and treat this potentially sight- and life-threatening spectrum of diseases and find the underlying systemic cause
NeuropatĂa Ăłptica isquĂ©mica y anticuerpos anticardiolipina de alto nivel en el sĂndrome de Sjogren primario
A 39-year-old woman with recurrent severe anterior ischemic optic neuropathy in the setting of Sjögren's syndrome was found to have high-titer IgM anticardiolipin antibodies (aCL) that were enhanced by the phospholipid-binding glycoprotein ?2GP1. The recognition of IgM aCL-associated vasculopathy as a possible etiologic factor in the optic neuropathy in Sjögren's syndrome may be relevant in deciding appropriate therapy
Recommended from our members
Accuracy of an objective binocular automated phoropter for providing spectacle prescriptions
Clinical relevance: Currently eye examinations are usually based on autorefraction followed by subjective refraction (SR) with a phoropter. An automated phoropter that can also perform autorefraction may facilitate the optometric workflow. Background: The efficiency and feasibility of an objective autorefraction and correction system are assessed by comparing objective refractive measurements with SR on the same subjects and evaluating the visual acuity (VA) values obtained after the objective refractive measurement and correction. Methods: Objective autorefraction and correction was performed on 41 subjects using an automated binocular phoropter system. The auto-phoropter performs autorefraction by wavefront measurement and corrects the spherical and cylindrical errors with tunable fluidic lenses while the patient looks at a visual display inside the instrument. The instrument outputs are optometric constants of spherical and cylindrical aberrations. After measurement and automated correction of the refractive errors, the VA values were assessed by having the subjects look at an integrated Snellen chart. The objective measurement results were statistically compared with their SR. Results: The correlations between SR and objective autorefraction and correction spherical equivalents (M) were 0.98 (0.97–0.99) and 0.96 (0.93–0.98), the vertical Jackson cross cylinder (J0) were 0.96 (0.92–0.98) and 0.95 (0.91–0.97), and the oblique Jackson cross cylinder (J45) were 0.73 (0.55–0.85) and 0.82 (0.69–0.90), for the right and left eyes, respectively, with the 95% confidence interval (CI) values in parentheses. 89.0% of the 82 eyes had at least 6/7.5 VA. Conclusions: A significant agreement between the SR and objective autorefraction and correction was observed. An all-objective refractive assessment with instantaneous verification may improve the precision of eye prescriptions and possibly reduce the procedure time.12 month embargo; first published 16 October 2023This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at [email protected]
ILC Reference Design Report Volume 1 - Executive Summary
The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization.The International Linear Collider (ILC) is a 200-500 GeV center-of-mass high-luminosity linear electron-positron collider, based on 1.3 GHz superconducting radio-frequency (SCRF) accelerating cavities. The ILC has a total footprint of about 31 km and is designed for a peak luminosity of 2x10^34 cm^-2s^-1. This report is the Executive Summary (Volume I) of the four volume Reference Design Report. It gives an overview of the physics at the ILC, the accelerator design and value estimate, the detector concepts, and the next steps towards project realization