7 research outputs found

    Uptake and release kinetics of 22 polar organic chemicals in the Chemcatcher passive sampler

    Get PDF
    The Chemcatcher passive sampler, which uses Empore™ disks as sampling phase, is frequently used to monitor polar organic chemicals in river water and effluents. Uptake kinetics need to be quantified to calculate time-weighted average concentrations from Chemcatcher field deployments. Information on release kinetics is needed if performance reference compounds (PRCs) are used to quantify the influence of environmental conditions on the uptake. In a series of uptake and elimination experiments, we used Empore™ SDB disks (poly(styrenedivinylbenzene) copolymer modified with sulfonic acid groups) as a sampling phase and 22 compounds with a logK ow (octanol-water partitioning coefficient) range from −2.6 to 3.8. Uptake experiments were conducted in river water or tap water and lasted up to 25days. Only 1 of 22 compounds (sulfamethoxazole) approached equilibrium in the uptake trials. Other compounds showed continuing non-linear uptake, even after 25days. All compounds could be released from SDB disks, and desorption was proportionally higher in disks loaded for shorter periods. Desorption showed two-phase characteristics, and desorption was proportionally higher for passively sorbed compounds compared to actively loaded compounds (active loading was performed by pulling spiked river water over SDB disks using vacuum). We hypothesise that the two-phase kinetics and better retention of actively loaded compounds—and compounds loaded for a longer period—may be caused by slow diffusion of chemicals within the polymer. As sorption and desorption did not show isotropic kinetics, it is not possible to develop robust PRCs for adsorbent material like SDB disk

    Corrosion protection products as a source of bisphenol A and toxicity to the aquatic environment

    No full text
    Steel components are typically treated with anti-corrosion coatings like epoxy or polyurethane resins to protect the integrity and functioning of steel. Such resins may contain substances, such as bisphenol A (BPA), that have caused concern in a human and environmental toxicological context. We investigated the release of toxicity from four anti-corrosion coatings used in hydraulic and civil engineering. Resins were applied onto glass plates and leachate samples produced by horizontally shaking the plates in water for 7 days. Two experiments were conducted, one with a 1 day and one with a 7 day curing period. Using a suite of bioassays, we tested samples for: agonistic and antagonistic effects on various mammalian nuclear receptors; inhibition of photosynthesis and growth in algae; inhibition of bacterial bioluminescence; and inhibition of water flea reproduction. Concentrations of BPA, bisphenol F and various BPA transformation products were determined by chemical analysis (LC-MS/MS). Bioassay results were evaluated using a scheme developed by DIBt (Centre of Competence for Construction, Berlin, Germany). Three products induced responses in one or more of the measured endpoints and toxicity profiles varied markedly in intensity across products. One product released high amounts of BPA which was associated with effects on nuclear receptor transactivation, requiring a more than 700-fold dilution for effect induction to fall below 20%. The same product was also the most toxic to water flea reproduction, requiring ca. 70-fold dilution for effects to fall below 20%. Another product was highly toxic in terms of bacterial bioluminescence, particularly after a shorter curing time, requiring a ca. 1'300-fold dilution for effects to fall below 20%. The third product required a 22-fold dilution for inhibition of water flea reproduction to drop below 20%. Results show that anti-corrosion coatings based on epoxy resins can be a source of toxicity to the aquatic environment. The fact that some products are more toxic than others highlights opportunities for the development of low risk formulations and products with better environmental performance. Finally, the DIBt scheme provides a useful starting point to develop further ecotoxicity guidelines for testing and data evaluation of leachates from construction materials. (C) 2017 Elsevier Ltd. All rights reserved

    Transfer Kinetics of Polar Organic Compounds over Polyethersulfone Membranes in the Passive Samplers Pocis and Chemcatcher

    No full text
    Passive samplers for polar organic compounds often use a polyethersulfone (PES) membrane to retain the particulate sorbent material (e.g., in a POCIS; polar organic chemical integrative sampler) or to reduce the sampling rate and thus extend the kinetic regime (e.g., in a Chemcatcher). The transport kinetics over the PES membrane are evaluated here in a short-term (6 days) and a long-term (32 days) experiment with POCIS and Chemcatchers. Passive samplers were placed in a channel with flowing river water that was spiked with 22 organic chemicals including pharmaceuticals, pesticides and biocides; with log<i>K</i><sub>ow</sub> (logarithmic octanol–water partitioning coefficient) values between −2.6 and 3.8. Samplers were removed at intervals and membranes and sorbent material were extracted and analyzed with LC-MS/MS. Uptake kinetics of the compounds fell between two extremes: (1) charged chemicals and chemicals of low hydrophobicity did not accumulate in PES and rapidly transferred to the sorbent (e.g., diclofenac) and (2) more hydrophobic chemicals accumulated strongly in the PES and appeared in the sorbent after a lag-phase (e.g., diazinon and diuron). Sorption kinetics were modeled with a three-compartment first-order kinetic model to determine uptake and elimination rate constants and partitioning coefficients. Water PES partitioning coefficients fitted with the model correlated well with experimentally determined values and log<i>K</i><sub>ow</sub>. Sampling rates of Chemcatcher (0.02–0.10 L/d) and POCIS (0.02–0.30 L/d) showed similar patterns and correlated well. Thus the samplers are interchangeable in practical applications. Longer lag-phases may pose problems when calculating time-weighted average aqueous concentrations for short passive sampling windows and for a correct integrative sampling of fluctuating concentrations

    Transfer kinetics of polar organic compounds over polyethersulfone membranes in the passive samplers Pocis and Chemcatcher

    No full text
    Passive samplers for polar organic compounds often use a polyethersulfone (PES) membrane to retain the particulate sorbent material (e.g., in a POCIS; polar organic chemical integrative sampler) or to reduce the sampling rate and thus extend the kinetic regime (e.g., in a Chemcatcher). The transport kinetics over the PES membrane are evaluated here in a short-term (6 days) and a long-term (32 days) experiment with POCIS and Chemcatchers. Passive samplers were placed in a channel with flowing river water that was spiked with 22 organic chemicals including pharmaceuticals, pesticides and biocides; with logK(ow) (logarithmic octanol-water partitioning coefficient) values between -2.6 and 3.8. Samplers were removed at intervals and membranes and sorbent material were extracted and analyzed with LC-MS/MS. Uptake kinetics of the compounds fell between two extremes: (1) charged chemicals and chemicals of low hydrophobicity did not accumulate in PES and rapidly transferred to the sorbent (e.g., diclofenac) and (2) more hydrophobic chemicals accumulated strongly in the PES and appeared in the sorbent after a lag-phase (e.g., diazinon and diuron). Sorption kinetics were modeled with a three-compartment first-order kinetic model to determine uptake and elimination rate constants and partitioning coefficients. Water PES partitioning coefficients fitted with the model correlated well with experimentally determined values and logK(ow). Sampling rates of Chemcatcher (0.02-0.10 L/d) and POCIS (0.02-0.30 L/d) showed similar patterns and correlated well. Thus the samplers are interchangeable in practical applications. Longer lag-phases may pose problems when calculating time-weighted average aqueous concentrations for short passive sampling windows and for a correct integrative sampling of fluctuating concentrations

    Uptake and release kinetics of 22 polar organic chemicals in the Chemcatcher passive sampler

    No full text
    The Chemcatcher passive sampler, which uses Empore (TM) disks as sampling phase, is frequently used to monitor polar organic chemicals in river water and effluents. Uptake kinetics need to be quantified to calculate time-weighted average concentrations from Chemcatcher field deployments. Information on release kinetics is needed if performance reference compounds (PRCs) are used to quantify the influence of environmental conditions on the uptake. In a series of uptake and elimination experiments, we used Empore (TM) SDB disks (poly(styrenedivinylbenzene) copolymer modified with sulfonic acid groups) as a sampling phase and 22 compounds with a logK (ow) (octanol-water partitioning coefficient) range from -2.6 to 3.8. Uptake experiments were conducted in river water or tap water and lasted up to 25 days. Only 1 of 22 compounds (sulfamethoxazole) approached equilibrium in the uptake trials. Other compounds showed continuing non-linear uptake, even after 25 days. All compounds could be released from SDB disks, and desorption was proportionally higher in disks loaded for shorter periods. Desorption showed two-phase characteristics, and desorption was proportionally higher for passively sorbed compounds compared to actively loaded compounds (active loading was performed by pulling spiked river water over SDB disks using vacuum). We hypothesise that the two-phase kinetics and better retention of actively loaded compounds-and compounds loaded for a longer period-may be caused by slow diffusion of chemicals within the polymer. As sorption and desorption did not show isotropic kinetics, it is not possible to develop robust PRCs for adsorbent material like SDB disks
    corecore