1,119 research outputs found
Proton and Helium Spectra from the CREAM-III Flight
Primary cosmic-ray elemental spectra have been measured with the
balloon-borne Cosmic Ray Energetics And Mass (CREAM) experiment since 2004. The
third CREAM payload (CREAM-III) flew for 29 days during the 2007-2008 Antarctic
season. Energies of incident particles above 1 TeV are measured with a
calorimeter. Individual elements are clearly separated with a charge resolution
of ~0.12 e (in charge units) and ~0.14 e for protons and helium nuclei,
respectively, using two layers of silicon charge detectors. The measured proton
and helium energy spectra at the top of the atmosphere are harder than other
existing measurements at a few tens of GeV. The relative abundance of protons
to helium nuclei is 9.53+-0.03 for the range of 1 TeV/n to 63 TeV/n. The ratio
is considerably smaller than other measurements at a few tens of GeV/n. The
spectra become softer above ~20 TeV. However, our statistical uncertainties are
large at these energies and more data are needed
Elemental energy spectra of cosmic rays measured by CREAM-II
We present new measurements of the energy spectra of cosmic-ray (CR) nuclei
from the second flight of the balloon-borne experiment CREAM (Cosmic Ray
Energetics And Mass). The instrument (CREAM-II) was comprised of detectors
based on different techniques (Cherenkov light, specific ionization in
scintillators and silicon sensors) to provide a redundant charge identification
and a thin ionization calorimeter capable of measuring the energy of cosmic
rays up to several hundreds of TeV. The data analysis is described and the
individual energy spectra of C, O, Ne, Mg, Si and Fe are reported up to ~ 10^14
eV. The spectral shape looks nearly the same for all the primary elements and
can be expressed as a power law in energy E^{-2.66+/-0.04}. The nitrogen
absolute intensity in the energy range 100-800 GeV/n is also measured.Comment: 4 pages, 3 figures, presented at ICRC 2009, Lodz, Polan
Measurements of cosmic-ray energy spectra with the 2nd CREAM flight
During its second Antarctic flight, the CREAM (Cosmic Ray Energetics And
Mass) balloon experiment collected data for 28 days, measuring the charge and
the energy of cosmic rays (CR) with a redundant system of particle
identification and an imaging thin ionization calorimeter. Preliminary direct
measurements of the absolute intensities of individual CR nuclei are reported
in the elemental range from carbon to iron at very high energy.Comment: 4 pages, 3 figures, presented at XV International Symposium on Very
High Energy Cosmic Ray Interactions (ISVHECRI 2008
Does shear wave ultrasound independently predict axillary lymph node metastasis in women with invasive breast cancer?
Shear wave elastography (SWE) shows promise as an adjunct to greyscale ultrasound examination in assessing breast masses. In breast cancer, higher lesion stiffness on SWE has been shown to be associated with features of poor prognosis. The purpose of this study was to assess whether lesion stiffness at SWE is an independent predictor of lymph node involvement. Patients with invasive breast cancer treated by primary surgery, who had undergone SWE examination were eligible. Data were retrospectively analysed from 396 consecutive patients. The mean stiffness values were obtained using the Aixplorer(®) ultrasound machine from SuperSonic Imagine Ltd. Measurements were taken from a region of interest positioned over the stiffest part of the abnormality. The average of the mean stiffness value obtained from each of two orthogonal image planes was used for analysis. Associations between lymph node involvement and mean lesion stiffness, invasive cancer size, histologic grade, tumour type, ER expression, HER-2 status and vascular invasion were assessed using univariate and multivariate logistic regression. At univariate analysis, invasive size, histologic grade, HER-2 status, vascular invasion, tumour type and mean stiffness were significantly associated with nodal involvement. Nodal involvement rates ranged from 7 % for tumours with mean stiffness <50 kPa to 41 % for tumours with a mean stiffness of >150 kPa. At multivariate analysis, invasive size, tumour type, vascular invasion, and mean stiffness maintained independent significance. Mean stiffness at SWE is an independent predictor of lymph node metastasis and thus can confer prognostic information additional to that provided by conventional preoperative tumour assessment and staging
Energy spectra of cosmic-ray nuclei at high energies
We present new measurements of the energy spectra of cosmic-ray (CR) nuclei
from the second flight of the balloon-borne experiment Cosmic Ray Energetics
And Mass (CREAM). The instrument included different particle detectors to
provide redundant charge identification and measure the energy of CRs up to
several hundred TeV. The measured individual energy spectra of C, O, Ne, Mg,
Si, and Fe are presented up to eV. The spectral shape looks
nearly the same for these primary elements and it can be fitted to an power law in energy. Moreover, a new measurement of the absolute
intensity of nitrogen in the 100-800 GeV/ energy range with smaller errors
than previous observations, clearly indicates a hardening of the spectrum at
high energy. The relative abundance of N/O at the top of the atmosphere is
measured to be (stat.)(sys.) at 800
GeV/, in good agreement with a recent result from the first CREAM flight.Comment: 32 pages, 10 figures. Accepted for publication in Astrophysical
Journa
Immunocytochemical determination of the subcellular distribution of ascorbate in plants
Ascorbate is an important antioxidant in plants and fulfills many functions related to plant defense, redox signaling and modulation of gene expression. We have analyzed the subcellular distribution of reduced and oxidized ascorbate in leaf cells of Arabidopsis thaliana and Nicotiana tabacum by high-resolution immuno electron microscopy. The accuracy and specificity of the applied method is supported by several observations. First, preadsorption of the ascorbate antisera with ascorbic acid or dehydroascorbic acid resulted in the reduction of the labeling to background levels. Second, the overall labeling density was reduced between 50 and 61% in the ascorbate-deficient Arabidopsis mutants vtc1-2 and vtc2-1, which correlated well with biochemical measurements. The highest ascorbate-specific labeling was detected in nuclei and the cytosol whereas the lowest levels were found in vacuoles. Intermediate labeling was observed in chloroplasts, mitochondria and peroxisomes. This method was used to determine the subcellular ascorbate distribution in leaf cells of plants exposed to high light intensity, a stress factor that is well known to cause an increase in cellular ascorbate concentration. High light intensities resulted in a strong increase in overall labeling density. Interestingly, the strongest compartment-specific increase was found in vacuoles (fourfold) and in plastids (twofold). Ascorbate-specific labeling was restricted to the matrix of mitochondria and to the stroma of chloroplasts in control plants but was also detected in the lumen of thylakoids after high light exposure. In summary, this study reveals an improved insight into the subcellular distribution of ascorbate in plants and the method can now be applied to determine compartment-specific changes in ascorbate in response to various stress situations
Cosmic-Ray Proton and Helium Spectra from the First CREAM Flight
Cosmic-ray proton and helium spectra have been measured with the
balloon-borne Cosmic Ray Energetics And Mass experiment flown for 42 days in
Antarctica in the 2004-2005 austral summer season. High-energy cosmic-ray data
were collected at an average altitude of ~38.5 km with an average atmospheric
overburden of ~3.9 g cm. Individual elements are clearly separated with
a charge resolution of ~0.15 e (in charge units) and ~0.2 e for protons and
helium nuclei, respectively. The measured spectra at the top of the atmosphere
are represented by power laws with a spectral index of -2.66 0.02 for
protons from 2.5 TeV to 250 TeV and -2.58 0.02 for helium nuclei from 630
GeV/nucleon to 63 TeV/nucleon. They are harder than previous measurements at a
few tens of GeV/nucleon. The helium flux is higher than that expected from the
extrapolation of the power law fitted to the lower-energy data. The relative
abundance of protons to helium nuclei is 9.1 0.5 for the range from 2.5
TeV/nucleon to 63 TeV/nucleon. This ratio is considerably smaller than the
previous measurements at a few tens of GeV/nucleon.Comment: 20 pages, 4 figure
Designing clinical trials in paediatric inflammatory bowel diseases:a PIBDnet commentary
Introduction: The optimal trial design for assessing novel therapies in paediatric IBD (PIBD) is a subject of intense ongoing global discussions and debate among the different stakeholders. However, there is a consensus that the current situation in which most medications used in children with IBD are prescribed as off-label without sufficient paediatric data is unacceptable. Shortening the time lag between adult and paediatric approval of drugs is of the upmost importance. In this position paper we aimed to provide guidance from the global clinical research network (Pediatric Inflammatory Bowel Disease Network, PIBDnet) for designing clinical trials in PIBD in order to facilitate drug approval for children.
Methods: A writing group has been established by PIBDnet and topics were assigned to different members. After an iterative process of revisions among the writing group and one face-to-face meeting, all statements have reached consensus of >80% as defined a priori. Next, all core members of PIBDnet voted on the statements, reaching consensus of >80% on all statements. Comments from the members were incorporated in the text.
Results: The commentary includes 18 statements for guiding data extrapolation from adults, eligibility criteria to PIBD trials, use of placebo, dosing, endpoints and recommendations for feasible trials. Controversial issues have been highlighted in the text.
Conclusion: The viewpoints expressed in this paper could assist planning clinical trials in PIBD which are both of high quality and ethical, while remaining pragmatic
- …