    Space Plasma Distribution Effect of Short-Circuit Arc on Generation of Secondary Arc

    No full text
    Secondary arc is more severe in the ultra-high voltage (UHV) power grid. However, the mechanism for the generation process of secondary arc at the extinction moment of a short-circuit arc is not yet clear. It is of great theoretical significance and technological application value to study the generation mechanism and dynamic physical characteristics of secondary arc, and further to develop effective suppression technology. In this article, an arc numerical simulation model based on the coefficient partial differential equations combining with classical drift-diffusion model was established, and the implementation method based on the finite element software COMSOL (COMSOL Multiphysics 5.2a, COMSOL Inc., Stockholm, Sweden) was given. Then, the transient analysis method was applied to simulate the generation, diffusion and dissipation phenomena of the short-circuit arc strike, and further to explore the electric field, microscopic particle spatial distribution and reaction process during the arc discharge process. The simulation results show that the development of short-circuit arc mainly includes two processes: corona discharge and arc discharge, of which the former has a very short duration and the latter is caused by short-circuit. During the discharge process, the electron density first increases and then decreases, which is different from the general characteristics of streamer discharge. Although the concentration distribution curve of the positive ions and negative ions has the same trend, there are subtle differences. The diffusion effect of space ions in the initial discharge stage is almost zero, while radial diffusion direction in the peak discharge stage and axial direction in the late discharge stage. The electric field intensity in space has an S-shaped upward trend during discharge. The time relationship of the ion source generated by the neutralization reaction and by the short-circuit arc discharge are basically the same, and the rate of neutralization reaction is lowest near the electrode. When the ionic reaction is approaching the end of the simulation, the ionic concentration is higher than the initial level, which proves that the space ionic concentration is increased due to the short-circuit discharge, and providing the necessary environmental conditions for the subsequent generation of the secondary arc

    Modeling study on the secondary arc with stochastic initial positions caused by the primary arc

    Get PDF
    In the conversion process from primary arc to secondary arc, there exists stochasticness phenomenon of the initial positions of secondary arc. However, the present simulation results of the arcing time with the arc chain model are constant, which is not consistent with the test results. In reaction to the above phenomenon, the stochastic simulation model was first established to calculate the relationship between the conductivity of the air and the temperature. Furthermore, the conductivity along the radius direction of the primary arc was acquired, and then the stochastic initial length of the secondary arc with different primary current was also obtained. Results showed that with the increase of primary current, the average value and dispersion of the initial secondary arc length also increased. Finally, the stochastic model of secondary arc with different initial positions was applied into the arc chain model to calculate the arcing time with dispersion, and the simulation results were compared with the experimental results. Results showed that the simulation results of the arcing time are consistent with the test results, and the relative errors are within 10%, which shows that the stochastic model is effective and reliable

    Study on Sulfide Distribution in the Operating Oil of Power Transformers and Its Effect on the Oil Quality

    No full text
    Corrosive sulfides in transformer oil could react with copper wire to produce cuprous sulfide, causing insulation failure. At present, both the quantitative measurement method and distribution of sulfur components in operating oil are not clear yet. In this paper, the existing types and contents of sulfides in oil samples with different alkyl groups and different voltage levels were investigated. With quantitative testing methods, the distribution of sulfur composition in the operating oil was analyzed. Results showed that the thiophene sulfide in transformer oil existed mainly in the form of benzothiophene with an unsaturation of 6 and dibenzothiophene with an unsaturation of 9. The content of monosulfide sulfide with unsaturation of 3 or 6 was the highest. The disulfide existed basically in the form of Dibenzyl disulfide (DBDS). The influence of sulfides on the oil quality were analyzed on this basis. Results showed that the existence of sulfides would increase the moisture content in oil. The absorbed moisture could cause the decrease of the breakdown voltage and rise of the dielectric loss. The above study could provide some engineering practice for understanding the sulphide distribution in transformer oils and further prevent the sulfur corrosion faults

    Micro‐mechanism study on synergistic degradation of the oil‐paper insulation with dibenzyl disulfide, hexadecyl mercaptan and benzothiophene

    No full text
    Abstract In recent years, there have been many cases of transformer failures caused by corrosive sulfides. At present, research mainly focuses on the single sulfide dibenzyl disulphide, but few research on multiple sulphur or the oil‐paper hybrid insulation. In this study, three typical sulfides dibenzyl disulfide, hexadecyl mercaptan and benzothiophene were selected to form seven sulfide‐oil‐paper models. Then relaxation calculations were carried out, and through molecular dynamics simulation, the synergistic effect of different sulfides on the properties of insulating paper and insulating oil was discussed. Results show that the coexistence of the three sulfides has the most severe weakening on the mechanical properties of cellulose, and it also causes great damage to hydrogen bonds. Hexadecyl mercaptan has a weaker effect on hydrogen bond destruction, but it will greatly aggravate the cellulose chain movement. The viscosity of insulating oil is generally increased by the influence of sulfide. Hexadecyl mercaptan is the main factor affecting the viscosity. Thiophene has little effect on the viscosity, ctive protection technology on sulphur corrosion

    Space Plasma Distribution Effect of Short-Circuit Arc on Generation of Secondary Arc

    No full text
    Secondary arc is more severe in the ultra-high voltage (UHV) power grid. However, the mechanism for the generation process of secondary arc at the extinction moment of a short-circuit arc is not yet clear. It is of great theoretical significance and technological application value to study the generation mechanism and dynamic physical characteristics of secondary arc, and further to develop effective suppression technology. In this article, an arc numerical simulation model based on the coefficient partial differential equations combining with classical drift-diffusion model was established, and the implementation method based on the finite element software COMSOL (COMSOL Multiphysics 5.2a, COMSOL Inc., Stockholm, Sweden) was given. Then, the transient analysis method was applied to simulate the generation, diffusion and dissipation phenomena of the short-circuit arc strike, and further to explore the electric field, microscopic particle spatial distribution and reaction process during the arc discharge process. The simulation results show that the development of short-circuit arc mainly includes two processes: corona discharge and arc discharge, of which the former has a very short duration and the latter is caused by short-circuit. During the discharge process, the electron density first increases and then decreases, which is different from the general characteristics of streamer discharge. Although the concentration distribution curve of the positive ions and negative ions has the same trend, there are subtle differences. The diffusion effect of space ions in the initial discharge stage is almost zero, while radial diffusion direction in the peak discharge stage and axial direction in the late discharge stage. The electric field intensity in space has an S-shaped upward trend during discharge. The time relationship of the ion source generated by the neutralization reaction and by the short-circuit arc discharge are basically the same, and the rate of neutralization reaction is lowest near the electrode. When the ionic reaction is approaching the end of the simulation, the ionic concentration is higher than the initial level, which proves that the space ionic concentration is increased due to the short-circuit discharge, and providing the necessary environmental conditions for the subsequent generation of the secondary arc