15 research outputs found

    The role of positron-emission tomography in the diagnosis of giant cell arteritis

    Get PDF
    Abstract Background: Giant cell arteritis (GCA) is an inflammatory disease of the larger vessels, typically affecting the temporal arteries, but involvement of the carotid and thoracic arteries is not uncommon. Serious complications such as blindness can occur if the disease is left untreated. Currently, the gold standard test for GCA is a temporal biopsy, but this invasive technique is not without risks and frequently inaccurate. We investigate the use of 18-fluoro-desoxyglucose (18F-FDG) positron emission tomography (PET) as a new diagnostic means in GCA. Methods: We performed a literature search in the MEDLINE database for original research articles written in the English language that discussed the use of PET in diagnosing GCA. After applying selection criteria, 9 articles were included for literature review and 4 of these were incorporated in a meta-analysis. Results: 18-FDG uptake in the extracranial arteries is correlated to the presence GCA within patients suspected for vasculitis. In our meta-analysis we found the following results: sensitivity 85% (95% CI; 74-92%, I2=0.0%), specificity 91% (95% CI; 82-96%, I2=31.2%), positive likelihood ratio 7.18 (95% CI; 3.43-15.06, I2 =10.1%) and negative likelihood ratio 0.19 (95% CI; 0.11-0.33, I2= 0.0%). Discussion: 18F-FDG-PET cannot replace temporal artery biopsy at the present time, because of its limited ability to visualise the cranial arteries. However, PET may be provide valuable information when extracranial involvement is suspected, specifically in biopsy-negative patients who are strongly suspected of having GCA

    Stroke Etiology and Thrombus Computed Tomography Characteristics in Patients With Acute Ischemic Stroke:A MR CLEAN Registry Substudy

    Get PDF
    Background and Purpose - If a relationship between stroke etiology and thrombus computed tomography characteristics exists, assessing these characteristics in clinical practice could serve as a useful additional diagnostic tool for the identification of stroke subtype. Our purpose was to study the association of stroke etiology and thrombus computed tomography characteristics in patients with acute ischemic stroke due to a large vessel occlusion. Methods - For 1429 consecutive patients enrolled in the MR CLEAN Registry, we determined stroke cause as defined by the TOAST (Trial of ORG 10172 in Acute Stroke Treatment) criteria. The association of stroke etiology with the hyperdense artery sign, clot burden score, and thrombus location was estimated with univariable and multivariable binary and ordinal logistic regression. Additionally, for 367 patients with available thin-section imaging, we assessed the association of stroke etiology with absolute and relative thrombus attenuation, distance from internal carotid artery-terminus to thrombus, thrombus length, and thrombus attenuation increase with univariable and multivariable linear regression. Results - Compared with cardioembolic strokes, noncardioembolic strokes were associated with presence of hyperdense artery sign (odds ratio, 2.2 [95% CI, 1.6-3.0]), lower clot burden score (common odds ratio, 0.4 [95% CI, 0.3-0.6]), shift towards a more proximal thrombus location (common odds ratio, 0.2 [95% CI, 0.2-0.3]), higher absolute thrombus attenuation (β, 3.6 [95% CI, 0.9-6.4]), decrease in distance from the ICA-terminus (β, -5.7 [95% CI, -8.3 to -3.0]), and longer thrombi (β, 8.6 [95% CI, 6.5-10.7]), based on univariable analysis. Thrombus characteristics of strokes with undetermined cause were similar to those of cardioembolic strokes. Conclusions - Thrombus computed tomography characteristics of cardioembolic stroke are distinct from those of noncardioembolic stroke. Additionally, our study supports the general hypothesis that many cryptogenic strokes have a cardioembolic cause. Further research should focus on the use of thrombus computed tomography characteristics as a diagnostic tool for stroke cause in clinical practice

    Acute Endovascular Treatment of Patients With lschemic Stroke From Intracranial Large Vessel Occlusion and Extracranial Carotid Dissection

    Get PDF
    Introduction: Carotid artery dissection (CAD) and atherosclerotic carotid artery occlusion (ACAO) are major causes of a tandem occlusion in patients with intracranial large vessel occlusion (LVO). Presence of tandem occlusions may hamper intracranial access and potentially increases the risk of procedural complications of endovascular treatment (EVT). Our aim was to assess neurological, functional and technical outcome and complications of EVT for intracranial LVO in patients with CAD in comparison to patients with ACAO and to patients without CAD or ACAO. Methods: We analyzed data of the MR CLEAN trial intervention arm and MR CLEAN Registry, acquired in 16 Dutch EVT-centers. Primary outcome was the change in stroke severity by comparing the National Institute of Health Stroke Scale (NIHSS) score at 24–48 h after treatment vs. baseline. Secondary outcomes included reperfusion rate and symptomatic intracranial hemorrhage (sICH). We compared outcomes and complications between patients with CAD vs. patients with ACAO and patients without CAD or ACAO. Results: In total, we identified 74 (4.7%) patients with CAD, 92 (5.9%) patients with ACAO and 1398 (89.4%) patients without CAD or ACAO. Neurological improvement at short-term after EVT in patients with CAD was significantly better compared to ACAO (resp. mean −5 vs. mean −1 NIHSS point; p = 0.03) and did not differ compared to patients without CAD or ACAO (−4 NIHSS points; p = 0.62). Rates of successful reperfusion in patients with CAD (47%) was comparable to patients with ACAO (47%; p = 1.00), but was less often achieved compared to patients without CAD or ACAO (58%; p = 0.08). Occurrence of sICH did not differ significantly between CAD patients (5%) and ACAO (11%; p = 0.33) or without CAD/ACAO (6%; p = 1.00). Conclusion: EVT in patients with intracranial LVO due to CAD results in neurological improvement comparable to patients without tandem occlusions. Therefore, carotid artery dissection by itself should not be a contraindicati

    Stroke Etiology and Thrombus Computed Tomography Characteristics in Patients With Acute Ischemic Stroke A MR CLEAN Registry Substudy

    No full text
    Background and Purpose-If a relationship between stroke etiology and thrombus computed tomography characteristics exists, assessing these characteristics in clinical practice could serve as a useful additional diagnostic tool for the identification of stroke subtype. Our purpose was to study the association of stroke etiology and thrombus computed tomography characteristics in patients with acute ischemic stroke due to a large vessel occlusion.Methods-For 1429 consecutive patients enrolled in the MR CLEAN Registry, we determined stroke cause as defined by the TOAST (Trial of ORG 10172 in Acute Stroke Treatment) criteria. The association of stroke etiology with the hyperdense artery sign, clot burden score, and thrombus location was estimated with univariable and multivariable binary and ordinal logistic regression. Additionally, for 367 patients with available thin-section imaging, we assessed the association of stroke etiology with absolute and relative thrombus attenuation, distance from internal carotid artery-terminus to thrombus, thrombus length, and thrombus attenuation increase with univariable and multivariable linear regression.Results-Compared with cardioembolic strokes, noncardioembolic strokes were associated with presence of hyperdense artery sign (odds ratio, 2.2 [95% CI, 1.6-3.0]), lower clot burden score (common odds ratio, 0.4 [95% CI, 0.3-0.6]), shift towards a more proximal thrombus location (common odds ratio, 0.2 [95% CI, 0.2-0.3]), higher absolute thrombus attenuation (beta, 3.6 [95% CI, 0.9-6.4]), decrease in distance from the ICA-terminus (beta, -5.7 [95% CI, -8.3 to -3.0]), and longer thrombi (beta, 8.6 [95% CI, 6.5-10.7]), based on univariable analysis. Thrombus characteristics of strokes with undetermined cause were similar to those of cardioembolic strokes.Conclusions-Thrombus computed tomography characteristics of cardioembolic stroke are distinct from those of noncardioembolic stroke. Additionally, our study supports the general hypothesis that many cryptogenic strokes have a cardioembolic cause. Further research should focus on the use of thrombus computed tomography characteristics as a diagnostic tool for stroke cause in clinical practice.Paroxysmal Cerebral Disorder

    Cardiovascular benefits of acupressure (Jin Shin) following stroke

    Get PDF
    Background and Purpose- If a relationship between stroke etiology and thrombus computed tomography characteristics exists, assessing these characteristics in clinical practice could serve as a useful additional diagnostic tool for the identification of stroke subtype. Our purpose was to study the association of stroke etiology and thrombus computed tomography characteristics in patients with acute ischemic stroke due to a large vessel occlusion. Methods- For 1429 consecutive patients enrolled in the MR CLEAN Registry, we determined stroke cause as defined by the TOAST (Trial of ORG 10172 in Acute Stroke Treatment) criteria. The association of stroke etiology with the hyperdense artery sign, clot burden score, and thrombus location was estimated with univariable and multivariable binary and ordinal logistic regression. Additionally, for 367 patients with available thin-section imaging, we assessed the association of stroke etiology with absolute and relative thrombus attenuation, distance from internal carotid artery-terminus to thrombus, thrombus length, and thrombus attenuation increase with univariable and multivariable linear regression. Results- Compared with cardioembolic strokes, noncardioembolic strokes were associated with presence of hyperdense artery sign (odds ratio, 2.2 [95% CI, 1.6-3.0]), lower clot burden score (common odds ratio, 0.4 [95% CI, 0.3-0.6]), shift towards a more proximal thrombus location (common odds ratio, 0.2 [95% CI, 0.2-0.3]), higher absolute thrombus attenuation (beta, 3.6 [95% CI, 0.9-6.4]), decrease in distance from the ICA-terminus (beta, -5.7 [95% CI, -8.3 to -3.0]), and longer thrombi (beta, 8.6 [95% CI, 6.5-10.7]), based on univariable analysis. Thrombus characteristics of strokes with undetermined cause were similar to those of cardioembolic strokes. Conclusions- Thrombus computed tomography characteristics of cardioembolic stroke are distinct from those of noncardioembolic stroke. Additionally, our study supports the general hypothesis that many cryptogenic strokes have a cardioembolic cause. Further research should focus on the use of thrombus computed tomography characteristics as a diagnostic tool for stroke cause in clinical practice

    Pyridylpiperazine-based allosteric inhibitors of RND-type multidrug efflux pumps

    No full text
    Efflux transporters of the RND family confer resistance to multiple antibiotics in Gram-negative bacteria. Here, we identify and chemically optimize pyridylpiperazine-based compounds that potentiate antibiotic activity in E. coli through inhibition of its primary RND transporter, AcrAB-TolC. Characterisation of resistant E. coli mutants and structural biology analyses indicate that the compounds bind to a unique site on the transmembrane domain of the AcrB L protomer, lined by key catalytic residues involved in proton relay. Molecular dynamics simulations suggest that the inhibitors access this binding pocket from the cytoplasm via a channel exclusively present in the AcrB L protomer. Thus, our work unveils a class of allosteric efflux-pump inhibitors that likely act by preventing the functional catalytic cycle of the RND pump

    Acute Endovascular Treatment of Patients With lschemic Stroke From Intracranial Large Vessel Occlusion and Extracranial Carotid Dissection

    No full text
    Neuro Imaging Researc

    Workflow Intervals of Endovascular Acute Stroke Therapy During On- Versus Off-Hours The MR CLEAN Registry

    No full text
    Neuro Imaging Researc

    Collateral Circulation and Outcome in Atherosclerotic Versus Cardioembolic Cerebral Large Vessel Occlusion

    No full text
    Neuro Imaging Researc

    Periprocedural Intravenous Heparin During Endovascular Treatment for Ischemic Stroke: Results From the MR CLEAN Registry

    No full text
    Neuro Imaging Researc
    corecore