644 research outputs found
Prospects for SIMPLE 2000: A large-mass, low-background Superheated Droplet Detector for WIMP searches
SIMPLE 2000 (Superheated Instrument for Massive ParticLE searches) will
consist of an array of eight to sixteen large active mass ( g)
Superheated Droplet Detectors(SDDs) to be installed in the new underground
laboratory of Rustrel-Pays d'Apt. Several factors make of SDDs an attractive
approach for the detection of Weakly Interacting Massive Particles (WIMPs),
namely their intrinsic insensitivity to minimum ionizing particles, high
fluorine content, low cost and operation near ambient pressure and temperature.
We comment here on the fabrication, calibration and already-competitive first
limits from SIMPLE prototype SDDs, as well as on the expected immediate
increase in sensitivity of the program, which aims at an exposure of 25
kg-day during the year 2000. The ability of modest-mass fluorine-rich detectors
to explore regions of neutralino parameter space beyond the reach of the most
ambitious cryogenic projects is pointed out.Comment: 19 pages, 10 figures included. New Journal of Physics, in pres
Superheated Microdrops as Cold Dark Matter Detectors
It is shown that under realistic background considerations, an improvement in
Cold Dark Matter sensitivity of several orders of magnitude is expected from a
detector based on superheated liquid droplets. Such devices are totally
insensitive to minimum ionizing radiation while responsive to nuclear recoils
of energies ~ few keV. They operate on the same principle as the bubble
chamber, but offer unattended, continuous, and safe operation at room
temperature and atmospheric pressure.Comment: 15 pgs, 4 figures include
The kinetic dark-mixing in the light of CoGENT and XENON100
Several string or GUT constructions motivate the existence of a dark U(1)_D
gauge boson which interacts with the Standard Model only through its kinetic
mixing. We compute the dark matter abundance in such scenario and the
constraints in the light of the recent data from CoGENT, CDMSII and XENON100.
We show in particular that a region with relatively light WIMPS, M_{Z_D}< 40
GeV and a kinetic mixing 10^-4 < delta < 10^-3 is not yet excluded by the last
experimental data and seems to give promising signals in a near future. We also
compute the value of the kinetic mixing needed to explain the
DAMA/CoGENT/CRESST excesses and find that for M_{Z_D}< 30 GeV, delta ~ 10^-3 is
sufficient to fit with the data.Comment: 6 pages, 5figure
Large-Mass Ultra-Low Noise Germanium Detectors: Performance and Applications in Neutrino and Astroparticle Physics
A new type of radiation detector, a p-type modified electrode germanium
diode, is presented. The prototype displays, for the first time, a combination
of features (mass, energy threshold and background expectation) required for a
measurement of coherent neutrino-nucleus scattering in a nuclear reactor
experiment. The device hybridizes the mass and energy resolution of a
conventional HPGe coaxial gamma spectrometer with the low electronic noise and
threshold of a small x-ray semiconductor detector, also displaying an intrinsic
ability to distinguish multiple from single-site particle interactions. The
present performance of the prototype and possible further improvements are
discussed, as well as other applications for this new type of device in
neutrino and astroparticle physics (double-beta decay, neutrino magnetic moment
and WIMP searches).Comment: submitted to Phys. Rev.
Technical aspects in dark matter investigations
Some theoretical and experimental aspects regarding the direct dark matter
field are mentioned. In particular some arguments, which play a relevant role
in the evaluation of model dependent interpretations of experimental results
and in comparisons, are shortly addressed.Comment: Proceedings of TAUP 2011 Conferenc
First Dark Matter Limits from a Large-Mass, Low-Background Superheated Droplet Detector
We report on the fabrication aspects and calibration of the first large
active mass ( g) modules of SIMPLE, a search for particle dark matter
using Superheated Droplet Detectors (SDDs). While still limited by the
statistical uncertainty of the small data sample on hand, the first weeks of
operation in the new underground laboratory of Rustrel-Pays d'Apt already
provide a sensitivity to axially-coupled Weakly Interacting Massive Particles
(WIMPs) competitive with leading experiments, confirming SDDs as a convenient,
low-cost alternative for WIMP detection.Comment: Final version, Phys. Rev. Lett. (in press
Development of Bubble Chambers With Enhanced Stability and Sensitivity to Low-Energy Nuclear Recoils
The viability of using a Bubble Chamber for rare event searches and in
particular for the detection of dark matter particle candidates is considered.
Techniques leading to the deactivation of inhomogeneous nucleation centers and
subsequent enhanced stability in such a detector are described. Results from
prototype trials indicate that sensitivity to low-energy nuclear recoils like
those expected from Weakly Interacting Massive Particles can be obtained in
conditions of near total insensitivity to minimum ionizing backgrounds. An
understanding of the response of superheated heavy refrigerants to these
recoils is demonstrated within the context of existing theoretical models. We
comment on the prospects for the detection of supersymmetric dark matter
particles with a large chamber.Comment: 4 pages, 3 figures. Submitted to Phys. Rev. Let
- âŠ