35 research outputs found

    The UK HeartSpare study: randomised evaluation of voluntary deep-inspiratory breath-hold in women undergoing breast radiotherapy

    Get PDF
    Purpose: to determine whether voluntary deep-inspiratory breath-hold (v_DIBH) and deep-inspiratory breath-hold with the active breathing coordinator™ (ABC_DIBH) in patients undergoing left breast radiotherapy are comparable in terms of normal-tissue sparing, positional reproducibility and feasibility of delivery.Methods: following surgery for early breast cancer, patients underwent planning-CT scans in v_DIBH and ABC_DIBH. Patients were randomised to receive one technique for fractions 1–7 and the second technique for fractions 8–15 (40?Gy/15 fractions total). Daily electronic portal imaging (EPI) was performed and matched to digitally-reconstructed radiographs. Cone-beam CT (CBCT) images were acquired for 6/15 fractions and matched to planning-CT data. Population systematic (?) and random errors (?) were estimated. Heart, left-anterior-descending coronary artery, and lung doses were calculated. Patient comfort, radiographer satisfaction and scanning/treatment times were recorded. Within-patient comparisons between the two techniques used the paired t-test or Wilcoxon signed-rank test.Results: twenty-three patients were recruited. All completed treatment with both techniques. EPI-derived ? were ?1.8?mm (v_DIBH) and ?2.0?mm (ABC_DIBH) and ? ?2.5?mm (v_DIBH) and ?2.2?mm (ABC_DIBH) (all p non-significant). CBCT-derived ? were ?3.9?mm (v_DIBH) and ?4.9?mm (ABC_DIBH) and ? ??4.1?mm (v_DIBH) and ??3.8?mm (ABC_DIBH). There was no significant difference between techniques in terms of normal-tissue doses (all p non-significant). Patients and radiographers preferred v_DIBH (p?=?0.007, p?=?0.03, respectively). Scanning/treatment setup times were shorter for v_DIBH (p?=?0.02, p?=?0.04, respectively).Conclusions: v_DIBH and ABC_DIBH are comparable in terms of positional reproducibility and normal tissue sparing. v_DIBH is preferred by patients and radiographers, takes less time to deliver, and is cheaper than ABC_DIB

    Chandra X-ray observations of the 3C295 cluster core

    Get PDF
    We examine the properties of the X-ray gas in the central regions of the distant (z=0.46), X-ray luminous cluster of galaxies surrounding the powerful radio source 3C 295, using observations made with the Chandra Observatory. Between radii of 50-500 kpc, the cluster gas is approximately isothermal with an emission-weighted temperature, kT ~5 keV. Within the central 50 kpc radius this value drops to kT ~3.7 keV. The spectral and imaging Chandra data indicate the presence of a cooling flow within the central 50 kpc radius of the cluster, with a mass deposition rate of approximately 280 solar masses per year. We estimate an age for the cooling flow of 1-2 Gyr, which is approximately one thousand times older than the central radio source. We find no evidence in the X-ray spectra or images for significant heating of the X-ray gas by the radio source. We report the detection of an edge-like absorption feature in the spectrum for the central 50 kpc region, which may be due to oxygen-enriched dust grains. The implied mass in metals seen in absorption could have been accumulated by the cooling flow over its lifetime. Combining the results on the X-ray gas density profile with radio measurements of the Faraday rotation measure in 3C295, we estimate the magnetic field strength in the region of the cluster core to be B ~12 \muG.Comment: 27 pages, 16 figs, 5 tables. Accepted for publication in MNRA

    Next-generation care pathways for allergic rhinitis and asthma multimorbidity: A model for multimorbid non-communicable diseases—Meeting Report (Part 2)

    Get PDF

    Search for gravitational waves from Scorpius X-1 in the second Advanced LIGO observing run with an improved hidden Markov model

    Get PDF
    We present results from a semicoherent search for continuous gravitational waves from the low-mass x-ray binary Scorpius X-1, using a hidden Markov model (HMM) to track spin wandering. This search improves on previous HMM-based searches of LIGO data by using an improved frequency domain matched filter, the J-statistic, and by analyzing data from Advanced LIGO's second observing run. In the frequency range searched, from 60 to 650 Hz, we find no evidence of gravitational radiation. At 194.6 Hz, the most sensitive search frequency, we report an upper limit on gravitational wave strain (at 95% confidence) of h095%=3.47×10-25 when marginalizing over source inclination angle. This is the most sensitive search for Scorpius X-1, to date, that is specifically designed to be robust in the presence of spin wandering. © 2019 American Physical Society

    The UK HeartSpare Study (Stage II): multicentre evaluation of a voluntary breath-hold technique in patients receiving breast radiotherapy

    Get PDF
    Aims To evaluate the feasibility and heart-sparing ability of the voluntary breath-hold (VBH) technique in a multicentre setting. Materials and methods Patients were recruited from 10 UK centres. Following surgery for early left breast cancer, patients with any heart inside the 50% isodose from a standard free-breathing tangential field treatment plan underwent a second planning computed tomography (CT) scan using the VBH technique. A separate treatment plan was prepared on the VBH CT scan and used for treatment. The mean heart, left anterior descending coronary artery (LAD) and lung doses were calculated. Daily electronic portal imaging (EPI) was carried out and scanning/treatment times were recorded. The primary end point was the percentage of patients achieving a reduction in mean heart dose with VBH. Population systematic (Σ) and random errors (σ) were estimated. Within-patient comparisons between techniques used Wilcoxon signed-rank tests. Results In total, 101 patients were recruited during 2014. Primary end point data were available for 93 patients, 88 (95%) of whom achieved a reduction in mean heart dose with VBH. Mean cardiac doses (Gy) for free-breathing and VBH techniques, respectively, were: heart 1.8 and 1.1, LAD 12.1 and 5.4, maximum LAD 35.4 and 24.1 (all P<0.001). Population EPI-based displacement data showed Σ =+1.3–1.9 mm and σ=1.4–1.8 mm. Median CT and treatment session times were 21 and 22 min, respectively. Conclusions The VBH technique is confirmed as effective in sparing heart tissue and is feasible in a multicentre setting

    Modulation of bovine articular chondrocyte gene expression in vitro by oxygen tension

    No full text
    AbstractObjective Adult articular cartilage is a physiologically hypoxic tissue with a proposed gradient of oxygen tension ranging from <10% oxygen at the cartilage surface to <1% in the deepest layers. This gradient may be disturbed during diseases of the joint, for example in rheumatoid arthritis when synovial fluid pO2falls. We investigated whether changes in oxygen tension modulate gene expression in articular chondrocytes.Design Bovine articular chondrocytes were cultured in alginate beads in medium maintained at <0.1, 5, 10 or 20% oxygen. A modified RNA arbitrarily primed polymerase chain reaction (RAP-PCR) technique was used to identify several genes whose mRNA abundance in articular chondrocytes was dependent upon oxygen tension. Northern hybridization slot blots were used to quantify changes in mRNA level relative to a housekeeping gene, β-actin.Results Genes found by RAP-PCR to undergo up-regulation in hypoxia included TIMP-1 and integrin-linked kinase. Collagen V mRNA levels were down-regulated in hypoxic chondrocytes. This led us to examine mRNA levels for various cytokines, matrix structural molecules and β1 integrin. Interleukin 1β, transforming growth factor β and connective tissue growth factor were all up-regulated by low oxygen tensions, as was β1 integrin. Collagen II (COL2A1) was down-regulated by hypoxia but aggrecan mRNA levels remained unchanged. The mRNA levels for GAPDH, the archetypal hypoxia responsive gene, were not modulated in articular chondrocytes by changes in oxygen tension.ConclusionsOxygen tension modulates the abundance of mRNAs encoding structural molecules, several cytokines, β1 integrin and integrin-linked kinase in articular chondrocytes. This may be important during disease progression. Chondrocytes are unusual in their response to hypoxia, presumably because they exist physiologically in a low oxygen environment
    corecore