3,520 research outputs found

    Dark matter directional detection with MIMAC

    Full text link
    MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for direct detection of non-baryonic dark matter. Measurement of both track and ionization energy will allow the electron-recoil discrimination, while access to the directionnality of the tracks will open a unique way to distinguish a geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV electrons are presented as a proof of concept.Comment: 4 pages, proc. of the 44th Rencontres De Moriond: Electroweak Interactions And Unified Theories, 7-14 Mar 2009, La Thuile, Ital

    Component-resolved diagnosis of pollen allergy based on skin testing with profilin, polcalcin and lipid transfer protein pan-allergens

    Full text link
    BACKGROUND Allergy diagnosis needs to be improved in patients suffering from pollen polysensitization due to the existence of possible confounding factors in this type of patients. OBJECTIVE To evaluate new diagnostic strategies by comparing skin responses to pan-allergens and conventional allergenic extracts with specific IgE (sIgE) to purified allergen molecules. METHODS One thousand three hundred and twenty-nine pollen-allergic patients were diagnosed by a combination of an in vitro method with a panel of 13 purified allergens, including major allergens and pan-allergens, using a high-capacity screening technology (ADVIA-Centaur®) and skin prick test (SPT) to pan-allergens and conventional extracts. RESULTS There was a high concordance (κ index) between in vitro (sIgE to major allergens) and in vivo (SPT to conventional extracts) methods in patients who were not sensitized to pan-allergens, but SPT with conventional extracts failed to diagnose patients with sensitization to pan-allergens. In patients who were simultaneously sensitized to polcalcins and profilins, there was a duplication both in the number of sensitizations to major allergens and in the years of disease evolution. There was a statistical association between sensitization to profilins and/or lipid transfer proteins and food allergy (P<0.0001). CONCLUSION The novel diagnostic strategy has proven to be a valuable tool in daily clinical practice. Introduction of routine SPT to pan-allergens is a simple and feasible way of improving diagnostic efficacy. Patients sensitized to pan-allergens should be tested by an adequate panel of allergenic molecules in order to identify the allergens that are responsible for the allergic disease

    First tests of a Micromegas TPC in a magnetic field

    Get PDF
    Talk given by P. ColasSince the summer of 2003, a large Micromegas TPC prototype (1000 channels, 50 cm drift, 50 cm diameter) has been operated in a 2T superconducting magnet at Saclay. A description of this apparatus and first results from cosmic ray tests are presented. Additional measurements using simpler detectors with a laser source, an X-ray gun and radio-active sources are discussed. Drift velocity and gain measurements, electron attachment and aging studies for a Micromegas TPC are presented. In particular, using simulations and measurements, it is shown that an ArgonCF4Argon-CF_4 mixture is optimal for operation at a future Linear Collider

    Micromegas in a Bulk

    Full text link
    In this paper we present a novel way to manufacture the bulk Micromegas detector. A simple process based on the PCB (Printed Circuit Board) technology is employed to produce the entire sensitive detector. Such fabrication process could be extended to very large area detectors made by the industry. The low cost fabrication together with the robustness of the electrode materials will make it extremely attractive for several applications ranging from particle physics and astrophysics to medicineComment: 6 pages, 4 figure

    Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal

    Full text link
    The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 μ\mum. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution with existing techniques using sub-millimeter width pads at the expense of a large increase in the detector cost and complexity. We have recently applied a new MPGD readout concept of charge dispersion to a prototype GEM-TPC and demonstrated the feasibility of achieving good resolution with pads similar in width to the ones used for the proportional wire TPC. The charge dispersion studies were repeated with a Micromegas TPC amplification stage. We present here our first results on the Micromegas-TPC resolution with charge dispersion. The TPC resolution with the Micromegas readout is compared to our earlier GEM results and to the resolution expected from electron statistics and transverse diffusion in a gaseous TPC.Comment: 5 pages, 8 figures, to appar in the Proceedings of the 2005 International Linear Collider Workshop (LCWS05), Stanford, 18-22 March 200

    Preparation of Barley Pollen Mother Cells for Confocal and Super Resolution Microscopy

    Get PDF
    Recombination (crossover) drives the release of genetic diversity in plant breeding programs. However, in barley, recombination is skewed toward the telomeric ends of its seven chromosomes, restricting the re-assortment of about 30% of the genes located in the centromeric regions of its large 5.1 Gb genome. A better understanding of meiosis and recombination could provide ways of modulating crossover distribution and frequency in barley as well as in other grasses, including wheat. While most research on recombination has been carried out in the model plant Arabidopsis thaliana, recent studies in barley (Hordeum Vulgare) have provided new insights into the control of crossing over in large genome species. A major achievement in these studies has been the use of cytological procedures to follow meiotic events. This protocol provides detailed practical steps required to perform immunostaining of barley meiocytes (pollen mother cells) for confocal or structured illumination microscopy.</p

    Ultra low energy results and their impact to dark matter and low energy neutrino physics

    Full text link
    We present ultra low energy results taken with the novel Spherical Proportional Counter. The energy threshold has been pushed down to about 25 eV and single electrons are clearly collected and detected. To reach such performance low energy calibration systems have been successfully developed: - A pulsed UV lamp extracting photoelectrons from the inner surface of the detector - Various radioactive sources allowing low energy peaks through fluorescence processes. The bench mark result is the observation of a well resolved peak at 270 eV due to carbon fluorescence which is unique performance for such large-massive detector. It opens a new window in dark matter and low energy neutrino search and may allow detection of neutrinos from a nuclear reactor or from supernova via neutrino-nucleus elastic scatteringComment: 14 pages,16 figure

    Progress on a spherical TPC for low energy neutrino detection

    Full text link
    The new concept of the spherical TPC aims at relatively large target masses with low threshold and background, keeping an extremely simple and robust operation. Such a device would open the way to detect the neutrino-nucleus interaction, which, although a standard process, remains undetected due to the low energy of the neutrino-induced nuclear recoils. The progress in the development of the fist 1 m3^3 prototype at Saclay is presented. Other physics goals of such a device could include supernova detection, low energy neutrino oscillations and study of non-standard properties of the neutrino, among others.Comment: 3 pages, talk given at the 9th Workshop on Topics in Astroparticle and Underground Physics, Zaragoza, September 10-1

    Micromegas TPC studies at high magnetic fields using the charge dispersion signal

    Get PDF
    The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD) readout TPC can achieve the target resolution with existing techniques using 1 mm or narrower pads at the expense of increased detector cost and complexity. The new MPGD readout technique of charge dispersion can achieve good resolution without resorting to narrow pads. This has been demonstrated previously for 2 mm x 6 mm pads with GEMs and Micromegas in cosmic ray tests and in a KEK beam test in a 1 Tesla magnet. We have recently tested a Micromegas-TPC using the charge dispersion readout concept in a high field super-conducting magnet at DESY. The measured Micromegas gain was found to be constant within 0.5% for magnetic fields up to 5 Tesla. With the strong suppression of transverse diffusion at high magnetic fields, we measure a flat 50 micron resolution at 5 Tesla over the full 15 cm drift length of our prototype TPC.Comment: 7 pages, 3 figure
    corecore