3,520 research outputs found
Dark matter directional detection with MIMAC
MiMac is a project of micro-TPC matrix of gaseous (He3, CF4) chambers for
direct detection of non-baryonic dark matter. Measurement of both track and
ionization energy will allow the electron-recoil discrimination, while access
to the directionnality of the tracks will open a unique way to distinguish a
geniune WIMP signal from any background. First reconstructed tracks of 5.9 keV
electrons are presented as a proof of concept.Comment: 4 pages, proc. of the 44th Rencontres De Moriond: Electroweak
Interactions And Unified Theories, 7-14 Mar 2009, La Thuile, Ital
Component-resolved diagnosis of pollen allergy based on skin testing with profilin, polcalcin and lipid transfer protein pan-allergens
BACKGROUND Allergy diagnosis needs to be improved in patients suffering from pollen polysensitization due to the existence of possible confounding factors in this type of patients. OBJECTIVE To evaluate new diagnostic strategies by comparing skin responses to pan-allergens and conventional allergenic extracts with specific IgE (sIgE) to purified allergen molecules. METHODS One thousand three hundred and twenty-nine pollen-allergic patients were diagnosed by a combination of an in vitro method with a panel of 13 purified allergens, including major allergens and pan-allergens, using a high-capacity screening technology (ADVIA-Centaur®) and skin prick test (SPT) to pan-allergens and conventional extracts. RESULTS There was a high concordance (κ index) between in vitro (sIgE to major allergens) and in vivo (SPT to conventional extracts) methods in patients who were not sensitized to pan-allergens, but SPT with conventional extracts failed to diagnose patients with sensitization to pan-allergens. In patients who were simultaneously sensitized to polcalcins and profilins, there was a duplication both in the number of sensitizations to major allergens and in the years of disease evolution. There was a statistical association between sensitization to profilins and/or lipid transfer proteins and food allergy (P<0.0001). CONCLUSION The novel diagnostic strategy has proven to be a valuable tool in daily clinical practice. Introduction of routine SPT to pan-allergens is a simple and feasible way of improving diagnostic efficacy. Patients sensitized to pan-allergens should be tested by an adequate panel of allergenic molecules in order to identify the allergens that are responsible for the allergic disease
First tests of a Micromegas TPC in a magnetic field
Talk given by P. ColasSince the summer of 2003, a large Micromegas TPC prototype (1000 channels, 50 cm drift, 50 cm diameter) has been operated in a 2T superconducting magnet at Saclay. A description of this apparatus and first results from cosmic ray tests are presented. Additional measurements using simpler detectors with a laser source, an X-ray gun and radio-active sources are discussed. Drift velocity and gain measurements, electron attachment and aging studies for a Micromegas TPC are presented. In particular, using simulations and measurements, it is shown that an mixture is optimal for operation at a future Linear Collider
Micromegas in a Bulk
In this paper we present a novel way to manufacture the bulk Micromegas
detector. A simple process based on the PCB (Printed Circuit Board) technology
is employed to produce the entire sensitive detector. Such fabrication process
could be extended to very large area detectors made by the industry. The low
cost fabrication together with the robustness of the electrode materials will
make it extremely attractive for several applications ranging from particle
physics and astrophysics to medicineComment: 6 pages, 4 figure
Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal
The Time Projection Chamber (TPC) for the International Linear Collider will
need to measure about 200 track points with a resolution close to 100 m. A
Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired
resolution with existing techniques using sub-millimeter width pads at the
expense of a large increase in the detector cost and complexity. We have
recently applied a new MPGD readout concept of charge dispersion to a prototype
GEM-TPC and demonstrated the feasibility of achieving good resolution with pads
similar in width to the ones used for the proportional wire TPC. The charge
dispersion studies were repeated with a Micromegas TPC amplification stage. We
present here our first results on the Micromegas-TPC resolution with charge
dispersion. The TPC resolution with the Micromegas readout is compared to our
earlier GEM results and to the resolution expected from electron statistics and
transverse diffusion in a gaseous TPC.Comment: 5 pages, 8 figures, to appar in the Proceedings of the 2005
International Linear Collider Workshop (LCWS05), Stanford, 18-22 March 200
Preparation of Barley Pollen Mother Cells for Confocal and Super Resolution Microscopy
Recombination (crossover) drives the release of genetic diversity in plant breeding programs. However, in barley, recombination is skewed toward the telomeric ends of its seven chromosomes, restricting the re-assortment of about 30% of the genes located in the centromeric regions of its large 5.1 Gb genome. A better understanding of meiosis and recombination could provide ways of modulating crossover distribution and frequency in barley as well as in other grasses, including wheat. While most research on recombination has been carried out in the model plant Arabidopsis thaliana, recent studies in barley (Hordeum Vulgare) have provided new insights into the control of crossing over in large genome species. A major achievement in these studies has been the use of cytological procedures to follow meiotic events. This protocol provides detailed practical steps required to perform immunostaining of barley meiocytes (pollen mother cells) for confocal or structured illumination microscopy.</p
Ultra low energy results and their impact to dark matter and low energy neutrino physics
We present ultra low energy results taken with the novel Spherical
Proportional Counter. The energy threshold has been pushed down to about 25 eV
and single electrons are clearly collected and detected. To reach such
performance low energy calibration systems have been successfully developed: -
A pulsed UV lamp extracting photoelectrons from the inner surface of the
detector - Various radioactive sources allowing low energy peaks through
fluorescence processes. The bench mark result is the observation of a well
resolved peak at 270 eV due to carbon fluorescence which is unique performance
for such large-massive detector. It opens a new window in dark matter and low
energy neutrino search and may allow detection of neutrinos from a nuclear
reactor or from supernova via neutrino-nucleus elastic scatteringComment: 14 pages,16 figure
Progress on a spherical TPC for low energy neutrino detection
The new concept of the spherical TPC aims at relatively large target masses
with low threshold and background, keeping an extremely simple and robust
operation. Such a device would open the way to detect the neutrino-nucleus
interaction, which, although a standard process, remains undetected due to the
low energy of the neutrino-induced nuclear recoils. The progress in the
development of the fist 1 m prototype at Saclay is presented. Other physics
goals of such a device could include supernova detection, low energy neutrino
oscillations and study of non-standard properties of the neutrino, among
others.Comment: 3 pages, talk given at the 9th Workshop on Topics in Astroparticle
and Underground Physics, Zaragoza, September 10-1
Micromegas TPC studies at high magnetic fields using the charge dispersion signal
The International Linear Collider (ILC) Time Projection Chamber (TPC)
transverse space-point resolution goal is 100 microns for all tracks including
stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas
Detector (MPGD) readout TPC can achieve the target resolution with existing
techniques using 1 mm or narrower pads at the expense of increased detector
cost and complexity. The new MPGD readout technique of charge dispersion can
achieve good resolution without resorting to narrow pads. This has been
demonstrated previously for 2 mm x 6 mm pads with GEMs and Micromegas in cosmic
ray tests and in a KEK beam test in a 1 Tesla magnet. We have recently tested a
Micromegas-TPC using the charge dispersion readout concept in a high field
super-conducting magnet at DESY. The measured Micromegas gain was found to be
constant within 0.5% for magnetic fields up to 5 Tesla. With the strong
suppression of transverse diffusion at high magnetic fields, we measure a flat
50 micron resolution at 5 Tesla over the full 15 cm drift length of our
prototype TPC.Comment: 7 pages, 3 figure
- …
