1,188 research outputs found

    Astrometric Positions and Proper Motions of 19 Radio Stars

    Full text link
    We have used the Very Large Array, linked with the Pie Town Very Long Baseline Array antenna, to determine astrometric positions of 19 radio stars in the International Celestial Reference Frame (ICRF). The positions of these stars were directly linked to the positions of distant quasars through phase referencing observations. The positions of the ICRF quasars are known to 0.25 mas, thus providing an absolute reference at the angular resolution of our radio observations. Average values for the errors in our derived positions for all sources were 13 mas and 16 mas in R.A. and declination respectively, with accuracies approaching 1-2 mas for some of the stars observed. Differences between the ICRF positions of the 38 quasars, and those measured from our observations showed no systematic offsets, with mean values of -0.3 mas in R.A. and -1.0 mas in declination. Standard deviations of the quasar position differences of 17 mas and 11 mas in R.A. and declination respectively, are consistent with the mean position errors determined for the stars. Our measured positions were combined with previous Very Large Array measurements taken from 1978-1995 to determine the proper motions of 15 of the stars in our list. With mean errors of approximately 1.6 mas/yr, the accuracies of our proper motions approach those derived from Hipparcos, and for a few of the stars in our program, are better than the Hipparcos values. Comparing the positions of our radio stars with the Hipparcos catalog, we find that at the epoch of our observations, the two frames are aligned to within formal errors of approximately 3 mas. This result confirms that the Hipparcos frame is inertial at the expected level.Comment: 20 pages, 9 figures Accepted by the Astronomical Journal, 2003 March 1

    Time-evolution of the Rule 150 cellular automaton activity from a Fibonacci iteration

    Get PDF
    The total activity of the single-seeded cellular rule 150 automaton does not follow a one-step iteration like other elementary cellular automata, but can be solved as a two-step vectorial, or string, iteration, which can be viewed as a generalization of Fibonacci iteration generating the time series from a sequence of vectors of increasing length. This allows to compute the total activity time series more efficiently than by simulating the whole spatio-temporal process, or even by using the closed expression.Comment: 4 pages (3 figs included

    SiS in the circumstellar envelope of IRC +10126: maser and quasi-thermal emission

    Full text link
    We present new Effelsberg-100 m, ATCA, and VLA observations of rotational SiS transitions in the circumstellar envelope (CSE) of IRC +10216. Thanks to the high angular resolution achieved by the ATCA observations, we unambiguously confirm that the molecule's J=1-0 transition exhibits maser action in this CSE, as first suggested more than thirty years ago. The maser emission's radial velocity peaking at a local standard of rest velocity of -39.862±\pm0.065 km/s indicates that it arises from an almost fully accelerated shell. Monitoring observations show time variability of the SiS (1-0) maser. The two lowest-JJ SiS quasi-thermal emission lines trace a much more extended emitting region than previous high-J SiS observations. Their distributions show that the SiS quasi-thermal emission consists of two components: one is very compact (radius<1.5", corresponding to <3×1015\times 10^{15} cm), and the other extends out to a radius >11". An incomplete shell-like structure is found in the north-east, which is indicative of existing SiS shells. Clumpy structures are also revealed in this CSE. The gain of the SiS (1-0) maser (optical depths of about -5 at the blue-shifted side and, assuming inversion throughout the entire line's velocity range, about -2 at the red-shifted side) suggests that it is unsaturated. The SiS (1-0) maser can be explained in terms of ro-vibrational excitation caused by infrared pumping, and we propose that infrared continuum emission is the main pumping source.Comment: Accepted for publication in ApJ. A high-resolution version can be found at https://gongyan2444.github.io/pdf/cw-leo-sis.pdf 3D movies of SiS cubes can be found at https://gongyan2444.github.io/movie/sis10-3d.avi and https://gongyan2444.github.io/movie/sis21-3d.av

    Analysis of the loop length distribution for the negative weight percolation problem in dimensions d=2 through 6

    Full text link
    We consider the negative weight percolation (NWP) problem on hypercubic lattice graphs with fully periodic boundary conditions in all relevant dimensions from d=2 to the upper critical dimension d=6. The problem exhibits edge weights drawn from disorder distributions that allow for weights of either sign. We are interested in in the full ensemble of loops with negative weight, i.e. non-trivial (system spanning) loops as well as topologically trivial ("small") loops. The NWP phenomenon refers to the disorder driven proliferation of system spanning loops of total negative weight. While previous studies where focused on the latter loops, we here put under scrutiny the ensemble of small loops. Our aim is to characterize -using this extensive and exhaustive numerical study- the loop length distribution of the small loops right at and below the critical point of the hypercubic setups by means of two independent critical exponents. These can further be related to the results of previous finite-size scaling analyses carried out for the system spanning loops. For the numerical simulations we employed a mapping of the NWP model to a combinatorial optimization problem that can be solved exactly by using sophisticated matching algorithms. This allowed us to study here numerically exact very large systems with high statistics.Comment: 7 pages, 4 figures, 2 tables, paper summary available at http://www.papercore.org/Kajantie2000. arXiv admin note: substantial text overlap with arXiv:1003.1591, arXiv:1005.5637, arXiv:1107.174

    Pulmonary Hypertension in Patients with Chronic Fibrosing Idiopathic Interstitial Pneumonias

    Get PDF
    Background Pulmonary hypertension (PH) is a common finding in patients with chronic fibrosing idiopathic interstitial pneumonias (IIP). Little is known about the response to pulmonary vasodilator therapy in this patient population. COMPERA is an international registry that prospectively captures data from patients with various forms of PH receiving pulmonary vasodilator therapies. Methods We retrieved data from COMPERA to compare patient characteristics, treatment patterns, response to therapy and survival in newly diagnosed patients with idiopathic pulmonary arterial hypertension (IPAH) and PH associated with IIP (PH-IIP). Results Compared to patients with IPAH (n = 798), patients with PH-IIP (n = 151) were older and predominantly males. Patients with PH-IIP were treated predominantly with phosphodiesterase-5 inhibitors (88% at entry, 87% after 1 year). From baseline to the first follow-up visit, the median improvement in 6MWD was 30 m in patients with IPAH and 24.5 m in patients with PH-IIP (p = 0.457 for the difference between both groups). Improvements in NYHA functional class were observed in 22.4% and 29.5% of these patients, respectively (p = 0.179 for the difference between both groups). Survival rates were significantly worse in PH-IIP than in IPAH (3-year survival 34.0 versus 68.6%; p<0.001). Total lung capacity, NYHA class IV, and mixed-venous oxygen saturation were independent predictors of survival in patients with PH-IIP. Conclusions Patients with PH-IIP have a dismal prognosis. Our results suggest that pulmonary vasodilator therapy may be associated with short-term functional improvement in some of these patients but it is unclear whether this treatment affects survival

    Weak and Compact Radio Emission in Early High-Mass Star Forming Regions: I. VLA Observations

    Get PDF
    We present a high sensitivity radio continuum survey at 6 and 1.3\,cm using the Karl G. Jansky Very Large Array towards a sample of 58 high-mass star forming regions. Our sample was chosen from dust clumps within infrared dark clouds with and without IR sources (CMC-IRs, CMCs, respectively), and hot molecular cores (HMCs), with no previous, or relatively weak radio continuum detection at the 11\,mJy level. Due to the improvement in the continuum sensitivity of the VLA, this survey achieved map rms levels of \sim 3-10 μ\muJy beam1^{-1} at sub-arcsecond angular resolution. We extracted 70 centimeter continuum sources associated with 1.2\,mm dust clumps. Most sources are weak, compact, and are prime candidates for high-mass protostars. Detection rates of radio sources associated with the mm dust clumps for CMCs, CMC-IRs and HMCs are 6%\%, 53%\% and 100%\%, respectively. This result is consistent with increasing high-mass star formation activity from CMCs to HMCs. The radio sources located within HMCs and CMC-IRs occur close to the dust clump centers with a median offset from it of 12,000\,AU and 4,000\,AU, respectively. We calculated 5 - 25\,GHz spectral indices using power law fits and obtain a median value of 0.5 (i.e., flux increasing with frequency), suggestive of thermal emission from ionized jets. In this paper we describe the sample, observations, and detections. The analysis and discussion will be presented in Paper II.Comment: Accepted for publication in the ApJ

    A paper based graphene-nanocauliflower hybrid composite for point of care biosensing

    Get PDF
    Graphene paper has diverse applications in printed circuit board electronics, bioassays, 3D cell culture, and biosensing. Although development of nanometal-graphene hybrid composites is commonplace in the sensing literature, to date there are only a few examples of nanometal-decorated graphene paper for use in biosensing. In this manuscript, we demonstrate the synthesis and application of Pt nano cauliflower-functionalized graphene paper for use in electrochemical biosensing of small molecules (glucose, acetone, methanol) or detection of pathogenic bacteria (Escherichia coli O157:H7). Raman spectroscopy, scanning electron microscopy and energy dispersive spectroscopy were used to show that graphene oxide deposited on nanocellulose crystals was partially reduced by both thermal and chemical treatment. Fractal platinum nanostructures were formed on the reduced graphene oxide paper, producing a conductive paper with an extremely high electroactive surface area, confirmed by cyclic voltammetry and electrochemical impedance spectroscopy. To show the broad applicability of the material, the platinum surface was functionalized with three different biomaterials: 1) glucose oxidase (via chitosan encapsulation); 2) a DNA aptamer (via covalent linking), or 3) a chemosensory protein (via his linking). We demonstrate the application of this device for point of care biosensing. The detection limit for both glucose (0.08 ± 0.02 μM) and E. coli O157:H7 (1.3 ± 0.1 CFU mL-1) were competitive with, or superior to, previously reported devices in the biosensing literature. The response time (6 sec for glucose and 10 min for E. coli) were also similar to silicon biochip and commercial electrode sensors. The results demonstrate that the nanocellulose-graphene-nanoplatinum material is an excellent paper-based platform for development of electrochemical biosensors targeting small molecules or whole cells for use in point of care biosensing

    VLA+PT Astrometry of 46 Radio Stars

    Get PDF
    We have used the Very Large Array (VLA), linked with the Pie Town Very Long Baseline Array antenna, to determine astrometric positions of 46 radio stars in the International Celestial Reference Frame (ICRF). Positions were obtained in the ICRF directly through phase referencing of the stars to nearby ICRF quasars whose positions are accurate at the 0.25 mas level. Radio star positions are estimated to be accurate at the 10 mas level, with position errors approaching a few milli-arcseconds for some of the stars observed. Our measured positions were combined with previous measurements taken from as early as 1978 to obtain proper motion estimates for all 46 stars with average uncertainties of ~1.7 mas/yr. We compared our radio star positions and proper motions with the Hipparcos Catalogue data, and find consistency in the reference frames produced by each data set on the 1-sigma level, with errors of ~2.7 mas per axis for the reference frame orientation angles at our mean epoch of 2003.78. No significant spin is found between our radio data frame and the Hipparcos Celestial Reference Frame (HCRF) with largest rotation rates of +0.55 and -0.41 mas/yr around the x and z axes, respectively, with 1-sigma errors of 0.36 mas/yr. Thus, our results are consistent with a non-rotating Hipparcos frame with respect to the ICRF.Comment: 29 pages, 8 figures, accepted for publication in the Astronomical Journa
    corecore