2,687 research outputs found
Mechanical breakdown of bent silicon nanowires imaged by coherent x-ray diffraction
We have developed a method of coherent x-ray diffractive imaging to surmount its inability to image the structure of strongly strained crystals. We used calculated models from finite–element analysis to guide an iterative algorithm to fit experimental data from a series of increasingly bent wires cut into silicon-on-insulator films. Just before mechanical fracture, the wires were found to contain new phase structures, which are identified as dislocations associated with crossing the elastic limit
Bragg projection ptychography on niobium phase domains
Bragg projection ptychography (BPP) is a coherent x-ray diffraction imaging technique which combines the strengths of scanning microscopy with the phase contrast of x-ray ptychography. Here we apply it for high resolution imaging of the phase-shifted crystalline domains associated with epitaxial growth. The advantages of BPP are that the spatial extent of the sample is arbitrary, it is nondestructive, and it gives potentially diffraction limited spatial resolution. Here we demonstrate the application of BPP for revealing the domain structure caused by epitaxial misfit in a nanostructured metallic thin film. Experimental coherent diffraction data were collected from a niobium thin film, epitaxially grown on a sapphire substrate as the beam was scanned across the sample. The data were analyzed by BPP using a carefully selected combination of refinement procedures. The resulting image shows a close packed array of epitaxial domains, shifted with respect to each other due to misfit between the film and its substrate
In vivo evaluation of ankle kinematics and tibiotalar joint contact strains using digital volume correlation and 3Â T clinical MRI
BACKGROUND: In vivo evaluation of ankle joint biomechanics is key to investigating the effect of injuries on the mechanics of the joint and evaluating the effectiveness of treatments. The objectives of this study were to 1) investigate the kinematics and contact strains of the ankle joint and 2) to investigate the correlation between the tibiotalar joint contact strains and the prevalence of osteochondral lesions of the talus distribution. METHODS: Eight healthy human ankle joints were subjected to compressive load and 3 T MRIs were obtained before and after applying load. The MR images in combination with digital volume correlation enabled non-invasive measurement of ankle joint kinematics and tibiotalar joint contact strains in three dimensions. FINDINGS: The total translation of the calcaneus was smaller (0.48 ± 0.15 mm, p < 0.05) than the distal tibia (0.93 ± 0.16 mm) and the talus (1.03 ± 0.26 mm). These movements can produce compressive and shear joint contact strains (approaching 9%), which can cause development of lesions on joints. 87.5% of peak tensile, compressive, and shear strains in the tibiotalar joint took place in the medial and lateral zones. INTERPRETATION: The findings suggested that ankle bones translate independently from each other, and in some cases in opposite directions. These findings help explain the distribution of osteochondral lesions of the talus which have previously been observed to be in medial and lateral regions of the talar dome in 90% of cases. They also provide a reason for the central region of talar dome being less susceptible to developing osteochondral lesions
Micro-beam Laue alignment of multi-reflection Bragg coherent diffraction imaging measurements
Multi-reflection Bragg coherent diffraction imaging has the potential to allow three-dimensional (3D) resolved measurements of the full lattice strain tensor in specific micro-crystals. Until now such measurements were hampered by the need for laborious, time-intensive alignment procedures. Here a different approach is demonstrated, using micro-beam Laue X-ray diffraction to first determine the lattice orientation of the micro-crystal. This information is then used to rapidly align coherent diffraction measurements of three or more reflections from the crystal. Based on these, 3D strain and stress fields in the crystal are successfully determined. This approach is demonstrated on a focused ion beam milled micro-crystal from which six reflections could be measured. Since information from more than three independent reflections is available, the reliability of the phases retrieved from the coherent diffraction data can be assessed. Our results show that rapid, reliable 3D coherent diffraction measurements of the full lattice strain tensor in specific micro-crystals are now feasible and can be successfully carried out even in heavily distorted samples
Imaging shape and strain in nanoscale engineered semiconductors for photonics by coherent x-ray diffraction
Coherent x-ray diffractive imaging is a nondestructive technique that extracts three-dimensional electron density and strain maps from materials with nanometer resolution. It has been utilized for materials in a range of applications, and has significant potential for imaging buried nanostructures in functional devices. Here, we show that coherent x-ray diffractive imaging is able to bring new understanding to a lithography-based nanofabrication process for engineering the optical properties of semiconducting GaAs1-yNy on a GaAs substrate. This technique allows us to test the process reliability and the manufactured patterns quality. We demonstrate that regular and sharp geometrical structures can be produced on a few-micron scale, and that the strain distribution is uniform even for highly strained sub-microscopic objects. This nondestructive study would not be possible using conventional microscopy techniques. Our results pave the way for tailoring the optical properties of emitters with nanometric precision for nanophotonics and quantum technology applications
Cryoelectron-microscopy structure of the enteropathogenic Escherichia coli type III secretion system EspA filament.
Enteropathogenic Escherichia coli (EPEC) and enterohemorrhagic Escherichia coli (EHEC) utilize a macromolecular type III secretion system (T3SS) to inject effector proteins into eukaryotic cells. This apparatus spans the inner and outer bacterial membranes and includes a helical needle protruding into the extracellular space. Thus far observed only in EPEC and EHEC and not found in other pathogenic Gram-negative bacteria that have a T3SS is an additional helical filament made by the EspA protein that forms a long extension to the needle, mediating both attachment to eukaryotic cells and transport of effector proteins through the intestinal mucus layer. Here, we present the structure of the EspA filament from EPEC at 3.4 Ă… resolution. The structure reveals that the EspA filament is a right-handed 1-start helical assembly with a conserved lumen architecture with respect to the needle to ensure the seamless transport of unfolded cargos en route to the target cell. This functional conservation is despite the fact that there is little apparent overall conservation at the level of sequence or structure with the needle. We also unveil the molecular details of the immunodominant EspA epitope that can now be exploited for the rational design of epitope display systems
Phase-Diverse Coherent Diffractive Imaging: High Sensitivity with Low Dose
This Letter demonstrates that coherent diffractive imaging (CDI), in combination with phase-diversity methods, provides reliable and artefact free high-resolution images. Here, using x rays, experimental results show a threefold improvement in the available image contrast. Furthermore, in conditions requiring low imaging dose, it is demonstrated that phase-diverse CDI provides a factor of 2 improvement in comparison to previous CDI techniques
High-resolution three-dimensional partially coherent diffraction imaging
The wave properties of light, particularly its coherence, are responsible for interference effects, which can be exploited in powerful imaging applications. Coherent diffractive imaging relies heavily on coherence and has recently experienced rapid growth. Coherent diffractive imaging recovers an object from its diffraction pattern by computational phasing with the potential of wavelength-limited resolution. Diminished coherence results in reconstructions that suffer from artefacts or fail completely. Here we demonstrate ab initio phasing of partially coherent diffraction patterns in three dimensions, while simultaneously determining the coherence properties of the illuminating wavefield. Both the dramatic improvements in image interpretability and the three-dimensional evaluation of the coherence will have broad implications for quantitative imaging of nanostructures and wavefield characterization with X-rays and electrons
Dynamic Imaging Using Ptychography
We demonstrate through experiment an example of “mixed state”reconstruction using x-ray ptychography. We demonstrate successful imaging of a vibrating sample that has dynamics that are of one order magnitude faster than the measurement times. We show how increased vibrational amplitude leads to an increased population of illumination modes, a characteristic of partial coherence. Implications of a vibrating sample are explored, with its possible use in manipulating coherent wave field mode shapes and coherence properties
Do bone mineral content and density determine fracture in children? A possible threshold for physical activity
BackgroundRelations between bone parameters, physical exertion, and childhood fractures are complex. We aimed to estimate the associations between fracture history and bone mineral content (BMC) and areal bone mineral density (aBMD) at 7 years of age, by levels of physical activity, as a proxy for trauma frequency.MethodsWe used data collected from 2,261 children of the Generation XXI birth cohort, assembled in 2005/6 in Porto, Portugal. At the age of 7 years (2012/4), fracture history, time spent per week in active play, and sports practice were reported by parents. Subtotal and lumbar spine (LS) BMC and aBMD were measured using whole-body dual-energy X-ray absorptiometry.ResultsBoys and girls in the highest categories of time spent in sports practice or active play generally had higher BMC and aBMD. Among girls, BMC and aBMD were protective of fracture only in the highest quarter of active play (>660 min/week)-odds ratios (OR; 95% confidence interval (95% CI)) for subtotal BMC=0.27 (0.11-0.67), subtotal aBMD=0.18 (0.06-0.49), and LS aBMD=0.41 (0.22-0.75). For boys in the highest quarter of sports practice (>240 min/week), subtotal and LS BMC were protective of fracture-OR=0.39 (0.16-0.98) and 0.51 (0.27-0.96), respectively.ConclusionIn prepubertal children, BMC and aBMD predicted fracture history only in the highest levels of physical activity.info:eu-repo/semantics/publishedVersio
- …