    Optimisation of Generation Models for Clusters of Photovoltaic Plants

    Get PDF
    The present work analyses the actual production profiles of a group of tens of thousands of PV plants. Actual PV generation profiles are represented as hourly average powers gathered from the energy meters measured at the point of common coupling with the grid. After filtering, data cleaning and statistical analysis, reference PV plants are selected for the improvements of the PV generation models. Production profiles are calculated by using literature generation models, with weather data as inputs. An optimisation is performed on the parameters of the literature models to minimise the differences between the cumulative distribution functions of calculated profiles and measured data. The study compares the performance of the different models and shows how the optimisation increases the quality of the calculated profiles

    Statistical Validation and Power Modelling of Hourly Profiles for a Large-Scale Photovoltaic Plant Portfolio

    Get PDF
    In the last decades, the number of photovoltaic (PV) generators significantly increased over the world. An accurate analysis of the massive data gathered from the meters of the PV plants can improve the management of their intermittent generation. This paper presents a methodology to analyse the production profiles of a portfolio of thousands of PV plants installed in an Italian region. The procedure faces the problem of filtering poor and incomplete data, then uses a stratified sampling technique for the statistical validation of the remaining profiles. Finally, the checked production profiles are used to adjust the energy model to better match the measured data and calculate the whole PV portfolio production

    Reliability analysis and repair activity for the components of 350 kw inverters in a large scale grid-connected photovoltaic system

    Get PDF
    The reliability of photovoltaic (PV) generators is strongly affected by the performance of Direct Current/Alternating Current (DC/AC) converters, being the major source of PV under-performance. However, generally, their reliability is not investigated at component level: thus, the present work presents a reliability analysis and the repair activity for the components of full bridge DC/AC converters. In the first part of the paper, a reliability analysis using failure rates from literature is carried out for 132 inverters (AC rated power of 350 kW each) with global AC power of 46 MW in a large scale grid-connected PV plant. Then, in the second part of the work, results from literature are compared with data obtained by analyzing industrial maintenance reports in the years 2015–2017. In conclusion, the yearly energy losses involved in the downtime are quantified, as well as their availability

    Maintenance Activity, Reliability, Availability, and Related Energy Losses in Ten Operating Photovoltaic Systems up to 1.8 MW

    Get PDF
    In general, photovoltaic (PV) plants do not include components with moving parts and, as a consequence, they are wrongly considered maintenance-free. Thus, this article presents a maintenance, reliability, and availability analysis of ten PV systems, with different inverter configurations, in the context of the intermittent renewable energy source systems, including the wind farms. The first part of the analysis consists of the evaluation of reliability using failure rates from the literature. In the second part, these results are compared with data obtained from industrial maintenance reports in the years 2016-2018. Finally, the yearly energy losses and the availability of each PV plant are assessed

    Innovative teaching on photovoltaic generation

    Get PDF
    One of the most important technologies for the renewable energy production is the Photovoltaic (PV) one. In the last decades, the enormous growth in the world of Photovoltaic installation capacity, and future trends, makes the knowledge of this topic fundamental for engineers working in the energy field with this competence, and not only. Thus, for students enrolled in industrial engineering courses, appropriate and innovative teaching methods are necessary. This paper aims to describe the structure of the course 'Photovoltaic Power Generation' in which solar resource and the photovoltaic generators, including power electronics, are explained. The topics of traditional theoretical lectures are presented, with the links to practical exercises and laboratories

    Experimental testing of a horizontal-axis wind turbine to assess its performance

    Get PDF
    This paper describes a test procedure to investigate the performance of a micro wind turbine with horizontal-axis. A 3D model of a rotor with five blades has been designed by a MATLAB software; its airfoil is optimized to efficiently work at low wind speed. The rotor is coupled to an electric generator and this equipment is tested in a wind tunnel. An anemometer is used to measure and set the desired wind speeds. Electric quantities, i.e., voltage, current and power, are acquired by a digital multimeter. A variable resistance is used to change the operating point of the generator. Preliminary results are reported that refer to the application of the proposed test procedures to a wind turbine with a 0.2 m2 swept area

    Comparison of correction methods of wind speed for performance evaluation of wind turbines

    Get PDF
    The performance of horizontal axis wind turbines strongly depends on the speed of the wind that enters in the rotor of the turbine. Unfortunately, this quantity is rarely available since the wind speed is measured on the back of the turbine, where a lower value is present. For this reason, two correction methods are usually employed that require two input quantities: the wind speed on the back of the turbine nacelle and the wind speed detected by a meteorological station close to the investigated turbine. Since an anemometric station is not always available, a third method is here proposed that does not require this input quantity. The proposed method relies on the wind speed on the back of the turbine and the manufacturer power curve. The effectiveness of such a method is shown by comparison to the results obtained with the standard methods implemented on a wind power plant in Southern Italy

    Innovative Laboratories for Teaching on Photovoltaic Generation in Higher Education

    Get PDF
    The production of energy from Photovoltaic technology is becoming more and more relevant. Therefore, it is essential that academic world focuses attention on this topic in order to properly teach and transmit knowledge, skills and abilities. These ones are very useful in work activities. The academic course 'Photovoltaic Power Generation' aims to better explain theoretical aspects by practical activities which require the implementation of innovative laboratories for learning. This paper presents the guidelines for replication of laboratory practices (twin labs), already offered to Italian students, in the context of the project EU-MONG

    Obturator prosthesis rehabilitation after maxillectomy: Functional and aesthetical analysis in 25 patients

    Get PDF
    The number of patients undergoing a surgical resection of the maxilla for oncological reasons is constantly increasing, the most common complication of which remains the communication between oral and nasal cavities. On the basis of data arising from the literature regarding the treatment options of maxillary oncological post-surgical defects, obturator prosthesis remains the most used worldwide. We studied 25 patients (with at least 1-year follow up) rehabilitated by obturator prosthesis after maxillary resection leading to oro-nasal communication, providing data on the objective/subjective evaluation of such rehabilitation and mastication performance measured by a two-color chewing gum test. The type of defect was classified according to the classification system proposed by Aramany. Among the patients in our study, 72% rated a higher score for either stability and retention than for aesthetic appearance, as confirmed by the Kapur score rated by clinicians. The two-color chewing gum test shows similar results as only one patient had insufficient chewing function. Interestingly, we found no correlation between the masticatory function and residual denture, confirming that the maxillary obturator remains a predictable solution in such patients regardless of the anatomical alterations following surgery
    • …
    corecore