29 research outputs found

    The Antarctic Submillimeter Telescope and Remote Observatory (AST/RO)

    Get PDF
    AST/RO, a 1.7 m diameter telescope for astronomy and aeronomy studies at wavelengths between 200 and 2000 microns, was installed at the South Pole during the 1994-1995 Austral summer. The telescope operates continuously through the Austral winter, and is being used primarily for spectroscopic studies of neutral atomic carbon and carbon monoxide in the interstellar medium of the Milky Way and the Magellanic Clouds. The South Pole environment is unique among observatory sites for unusually low wind speeds, low absolute humidity, and the consistent clarity of the submillimeter sky. Four heterodyne receivers, an array receiver, three acousto-optical spectrometers, and an array spectrometer are installed. A Fabry-Perot spectrometer using a bolometric array and a Terahertz receiver are in development. Telescope pointing, focus, and calibration methods as well as the unique working environment and logistical requirements of the South Pole are described.Comment: 57 pages, 15 figures. Submitted to PAS

    The Sample Analysis at Mars Investigation and Instrument Suite

    Full text link

    Randomized Evaluation of the TriActiv Balloon-Protection Flush and Extraction System for the Treatment of Saphenous Vein Graft Disease

    Get PDF
    ObjectivesThe Protection During Saphenous Vein Graft Intervention to Prevent Distal Embolization (PRIDE) study compared outcomes with the TriActiv System (Kensey Nash Corp., Exton, Pennsylvania), a balloon-protection flush and extraction device, with an embolic protection group during treatment of saphenous venous grafts (SVGs).BackgroundTreatment of SVGs with embolic protection reduces adverse cardiac events.MethodsWe conducted a prospective trial randomizing 631 patients with coronary ischemia and lesions in SVGs to embolic protection with the TriActiv System or control group (Guardwire System [Medtronic AVE, Santa Rosa, California] or Filterwire EX [Boston Scientific Corp., Maple Grove, Minnesota]).ResultsThe incidence of major adverse cardiac events at 30 days was 11.2% for the TriActiv group and 10.1% for the control group (relative risk = 1.1%; 95% confidence interval 0.67 to 1.76; p = 0.65; p = 0.02 for non-inferiority). Safety and efficacy end points were similar between groups except that patients randomized to the TriActiv System had more hemorrhagic complications (10.9% vs. 5.4%; p = 0.01).ConclusionsThe TriActiv System was not inferior to approved embolic protection devices for the treatment of diseased SVGs

    Using Open-Source Tools to Fulfill Digital Preservation Requirements

    No full text
    This workshop offers a space to talk about open-source software for digital preservation, and the particular challenges of developing systems and integrating them into local environments and workflows. Topics will include current efforts and grant-funded initiatives to integrate different open source archival software tools; the development of workflows involving multiple open source tools for digital preservation, forensics, discovery and access; and the identification of gaps which may need filled by these or other tools
    corecore