111 research outputs found

    Extended cavity diode lasers with tracked resonances

    Full text link
    We present a painless, almost-free upgrade to present extended cavity diode lasers (ECDLs), which improves the long term mode-hop free performance by stabilizing the resonance of the internal cavity to the external cavity. This stabilization is based on the observation that the frequency or amplitude noise of the ECDL is lowest at the optimum laser diode temperature or injection current. Thus, keeping the diode current at the level where the noise is lowest ensures mode-hop free operation within one of the stable regions of the mode chart, even if these should drift due to external influences. This method can be applied directly to existing laser systems without modifying the optical setup. We demonstrate the method in two ECDLs stabilized to vapor cells at 852 nm and 895 nm wavelength. We achieve long term mode-hop free operation and low noise at low power consumption, even with an inexpensive non-antireflection coated diode.Comment: 5 pages, 6 figure

    An Approach to Assertion Application via Generalised Resolution

    Get PDF
    In this paper we address assertion retrieval and application in theorem proving systems or proof planning systems for classical first-order logic. Due to Huang the notion of assertion comprises mathematical knowledge such as definitions, theorems, and axioms. We propose a distributed mediator module between a mathematical knowledge base KB and a theorem proving system TP which is independent of the particular proof representation format of TP and which applies generalised resolution in order to analyze the logical consequences of arbitrary assertions for a proof context at hand. Our approach is applicable also to the assumptions which are dynamically created during a proof search process. It therefore realises a crucial first step towards full automation of assertion level reasoning. We discuss the benefits and connection of our approach to proof planning and motivate an application in a project aiming at a tutorial dialogue system for mathematics

    Bose-Einstein condensate as a quantum memory for a photonic polarization qubit

    Full text link
    A scheme based on electromagnetically induced transparency is used to store light in a Bose-Einstein condensate. In this process, a photonic polarization qubit is stored in atomic Zeeman states. The performance of the storage process is characterized and optimized. The average process fidelity is 1.000 +/- 0.004. For long storage times, temporal fluctuations of the magnetic field reduce this value, yielding a lifetime of the fidelity of 1.1 +/- 0.2 ms. The write-read efficiency of the pulse energy can reach 0.53 +/- 0.05

    My migraine voice survey. aA global study of disease burden among individuals with migraine for whom preventive treatments have failed

    Get PDF
    Background: Migraine is associated with many debilitating symptoms that affect daily functioning. My Migraine Voice is a large global cross-sectional study aimed at understanding the full burden and impact of migraine directly from patients suffering from ≥4 monthly migraine days (MMDs) with a history of prophylactic treatment failure. Methods: This study was conducted worldwide (31 countries across North and South Americas, Europe, the Middle East and Northern Africa, and the Asia-Pacific region) using an online survey administered to adults with migraine who reported ≥4 MMDs in the 3 months preceding survey administration, with pre-specified criteria of 90% having used preventive migraine treatment (80% with history of ≥1 treatment failure). Prophylactic treatment failure was defined as a reported change in preventive medication by individuals with migraine for any reason, at least once. Results: In total, 11,266 individuals participated in the survey. Seventy-four percent of the participants reported spending time in darkness/isolation due to migraine (average: 19 h/month). While 85% of all respondents reported negative aspects of living with migraine (feeling helpless, depressed, not understood), sleeping difficulties (83%), and fear of the next attack (55%), 57% shared ≥1 positive aspect (learning to cope, becoming a stronger person). Forty-nine percent reported feeling limited in daily activities throughout all migraine phases. Migraine impact on professional, private, or social domains was reported by 87% of respondents (51% in all domains). In the previous 12 months, 38% of respondents had visited the emergency department (average: 3.3 visits), whereas 23% stayed in hospital overnight (average: 3.2 nights) due to migraine. Conclusions: The burden of migraine is substantial among this cohort of individuals with at least 4 migraine days per month and for whom at least 1 preventive migraine treatment had failed. Interestingly, respondents reported some positive aspects in their migraine journey; the greater resilience and strength brought on by coping with migraine suggests that if future treatments could address existing unmet needs, these individuals with migraine will be able to maximize their contribution to society

    Controlling a magnetic Feshbach resonance with laser light

    Full text link
    The capability to tune the strength of the elastic interparticle interaction is crucial for many experiments with ultracold gases. Magnetic Feshbach resonances are a tool widely used for this purpose, but future experiments would benefit from additional flexibility such as spatial modulation of the interaction strength on short length scales. Optical Feshbach resonances offer this possibility in principle, but suffer from fast particle loss due to light-induced inelastic collisions. Here we show that light near-resonant with a molecular bound-to-bound transition can be used to shift the magnetic field at which a magnetic Feshbach resonance occurs. This makes it possible to tune the interaction strength with laser light and at the same time induce considerably less loss than an optical Feshbach resonance would do

    Ovarian and Breast Cancer Risks Associated With Pathogenic Variants in RAD51C and RAD51D.

    Get PDF
    BACKGROUND: The purpose of this study was to estimate precise age-specific tubo-ovarian carcinoma (TOC) and breast cancer (BC) risks for carriers of pathogenic variants in RAD51C and RAD51D. METHODS: We analyzed data from 6178 families, 125 with pathogenic variants in RAD51C, and 6690 families, 60 with pathogenic variants in RAD51D. TOC and BC relative and cumulative risks were estimated using complex segregation analysis to model the cancer inheritance patterns in families while adjusting for the mode of ascertainment of each family. All statistical tests were two-sided. RESULTS: Pathogenic variants in both RAD51C and RAD51D were associated with TOC (RAD51C: relative risk [RR] = 7.55, 95% confidence interval [CI] = 5.60 to 10.19; P = 5 × 10-40; RAD51D: RR = 7.60, 95% CI = 5.61 to 10.30; P = 5 × 10-39) and BC (RAD51C: RR = 1.99, 95% CI = 1.39 to 2.85; P = 1.55 × 10-4; RAD51D: RR = 1.83, 95% CI = 1.24 to 2.72; P = .002). For both RAD51C and RAD51D, there was a suggestion that the TOC relative risks increased with age until around age 60 years and decreased thereafter. The estimated cumulative risks of developing TOC to age 80 years were 11% (95% CI = 6% to 21%) for RAD51C and 13% (95% CI = 7% to 23%) for RAD51D pathogenic variant carriers. The estimated cumulative risks of developing BC to 80 years were 21% (95% CI = 15% to 29%) for RAD51C and 20% (95% CI = 14% to 28%) for RAD51D pathogenic variant carriers. Both TOC and BC risks for RAD51C and RAD51D pathogenic variant carriers varied by cancer family history and could be as high as 32-36% for TOC, for carriers with two first-degree relatives diagnosed with TOC, or 44-46% for BC, for carriers with two first-degree relatives diagnosed with BC. CONCLUSIONS: These estimates will facilitate the genetic counseling of RAD51C and RAD51D pathogenic variant carriers and justify the incorporation of RAD51C and RAD51D into cancer risk prediction models

    Time to culture positivity and sputum smear microscopy during tuberculosis therapy.

    Get PDF
    Sputum smear microscopy is widely used for tuberculosis diagnosis and treatment monitoring. We evaluated the correlation between smear microscopy and time to liquid culture positivity during early tuberculosis treatment. The study included patients with smear-positive pulmonary tuberculosis hospitalized at a tuberculosis reference centre in Germany between 01/2012 and 05/2013. Patient records were reviewed and clinical, radiological and microbiological data were analysed. Sputum samples were collected before treatment initiation and weekly thereafter. A number of 310 sputum samples from 30 patients were analysed. Time to liquid culture positivity inversely correlated with smear grade (Spearman's rho -0.439, p<0.001). There was a better correlation within the first two months vs. after two months of therapy (-0.519 vs. -0.416) with a trend to a more rapid increase in time to positivity between baseline and week 2 in patients who culture-converted within the first two months (5.9 days vs. 9.4 days, p = 0.3). In conclusion, the numbers of acid-fast bacilli in sputum smears of patients with pulmonary tuberculosis and time to culture positivity for M. tuberculosis cultures from sputum are correlated before and during tuberculosis treatment. A considerable proportion of patients with culture conversion after two months of therapy continued to have detectable acid-fast bacilli on sputum smears
    corecore