3 research outputs found

    B-mode sonographic evaluation of optic nerve sheath diameter and lens thickness in Nigerian adults with glaucoma

    Get PDF
    Objective: This study was done to investigate the effect(s) of glaucoma on the ocular optic nerve sheath diameter and lens thickness using B-mode ultrasonography.Materials and methods: One hundred and twenty study participants were recruited; 60 subjects with glaucoma and 60 age- and sex-matched controls without glaucoma. The optic nerve sheath diameter and lens thickness of both eyes were measured using a linear high frequency transducer with frequency of 6.5-12MHz.Results: The mean optic nerve sheath diameter of the glaucomatous eyes (3.57 ± 0.19mm and 3.59 ± 0.33mm on the right and left, respectively) were significantly thinner than that of controls (4.23 ± 0.34 mm and 4.26 ± 0.30 mm on the right and left, respectively; p < 0.001). There is increased mean lens thickness in the glaucomatous eyes (4.15 ± 0.43mm and 4.18 ± 0.46mm on the right and left, respectively) than in the controls (4.01 ± 0.56mm and 3.99 ± 0.45mm on the right and left, respectively) with a statistically significant difference seen in the left eye (p = 0.024).Conclusion: B-mode ultrasound is a reliable tool of assessing the nerve sheath diameter and lens thickness in glaucoma. Optic nerve sheath diameter is reduced in glaucomaKeywords: Glaucoma, ultrasonography, optic nerve sheath diameter, lens thickness

    B-mode sonographic evaluation of optic nerve sheath diameter and lens thickness in Nigerian adults with glaucoma

    Get PDF
    Objective: This study was done to investigate the effect(s) of glaucoma on the ocular optic nerve sheath diameter and lens thickness using B-mode ultrasonography. Materials and methods: One hundred and twenty study participants were recruited; 60 subjects with glaucoma and 60 age- and sex-matched controls without glaucoma. The optic nerve sheath diameter and lens thickness of both eyes were measured using a linear high frequency transducer with frequency of 6.5-12MHz. Results: The mean optic nerve sheath diameter of the glaucomatous eyes (3.57 \ub1 0.19mm and 3.59 \ub1 0.33mm on the right and left, respectively) were significantly thinner than that of controls (4.23 \ub1 0.34 mm and 4.26 \ub1 0.30 mm on the right and left, respectively; p < 0.001). There is increased mean lens thickness in the glaucomatous eyes (4.15 \ub1 0.43mm and 4.18 \ub1 0.46mm on the right and left, respectively) than in the controls (4.01 \ub1 0.56mm and 3.99 \ub1 0.45mm on the right and left, respectively) with a statistically significant difference seen in the left eye (p = 0.024). Conclusion: B-mode ultrasound is a reliable tool of assessing the nerve sheath diameter and lens thickness in glaucoma. Optic nerve sheath diameter is reduced in glaucom
    corecore