141 research outputs found
Impedance drop determines ablation lesion volume at the same level of ablation index
New parameters such as ablation index (AI) have been developed to create reliable ablation lesions. This study was performed to evaluate whether RF energy delivery with the same ablation index creates the similar ablation lesion volume. Ablation lesions were created in 5 pig hearts at ex-vivo state. Ablation was performed using an external-irrigation contact-force sensing catheter on the epicardial side of the left ventricle with 90-degree of angle. RF ablation time was adjusted for targeting AI 600 at 8 different conditions. Lesion volume created with 0–5g of contact force at 20 W was significantly lower than that of 11–20g at 40W despite of the same AI (125 ± 76.2 vs. 272 ± 49.5 mm3, P < 0.05). Quality of ablation lesion was variable in the condition of poor contact at low power for the ablation of ex-vivo swine left ventricle, and high-quality lesions could be expected when the impedance drop is satisfactory even though the same level of AI is applied during ablation
Young age: an independent risk factor for disease-free survival in women with operable breast cancer
BACKGROUND: The incidence of breast cancer in young women (age < 35) is low. The biology of the disease in this age group is poorly understood, and there are conflicting data regarding the prognosis for these women compared to older patients. METHODS: We retrospectively analyzed 2040 consecutive primary invasive breast cancer patients who underwent surgical procedures at our institution between 1990 and 1999. The younger age group was defined as patients aged <35 years at the time of diagnosis. The clinicopathological characteristics and treatment outcomes were compared between younger and older age groups. RESULTS: A total of 256 (12.5%) patients were aged <35. There was a significantly higher incidence of nuclear grade 3 and medullary histological-type tumors in younger patients compared to older patients. Axillary lymph node status, T stage, histological grade, c-erbB2 expression and estrogen receptor status did not differ significantly between the two age groups. Younger patients had a greater probability of recurrence and death at all time periods. Although there was no significant difference in disease-free survival between the two age groups in lymph node-negative patients, the younger group showed worse prognosis among lymph node-positive patients (p < 0.001). In multivariate analysis, young age remained a significant predictor of recurrence (p = 0.010). CONCLUSION: Young age (<35) is an independent risk factor for relapse in operable breast cancer patients
Differentiation of the right versus left outflow tract ventricular arrhythmias using local activation time at the His bundle electrogram
Background
Although multiple algorithms based on surface electrocardiographic criteria have been introduced to localize idiopathic ventricular arrhythmia (VA) origins from the outflow tract (OT), their diagnostic accuracy and clinical usefulness remain limited. We evaluated whether local activation time of the His bundle region could differentiate left and right ventricular OT VA origins in the early stage of electrophysiology study.
Methods
We studied 30 patients who underwent catheter ablation for OT VAs with a left bundle branch block pattern and inferior axis QRS morphology. The interval between the local V signal on the mapping catheter placed in the RVOT and His bundle region (V(RVOT)-V(HB) interval) and the interval from QRS complex onset to the local V signal on the His bundle region (QRS-V(HB) interval) were measured during VAs.
Results
The V(RVOT)-V(HB) and QRS-V(HB) intervals were significantly shorter in patients with LVOT VAs. The area under the curve (AUC) for the V(RVOT)-V(HB) interval by receiver operating characteristic analysis was 0.865. A cutoff value of ≤ 50 ms predicted an LVOT origin of VA with sensitivity, specificity, and positive and negative predictive values of 100%, 62.5%, 40%, and 100%, respectively. The QRS-V(HB) interval showed similar diagnostic accuracy (AUC, 0.840), and a cutoff value of ≤ 15 ms predicted an LVOT origin of VA with a sensitivity, specificity, and positive and negative predictive values of 100%, 70.8%, 45.2%, and 100%, respectively.
Conclusion
The V(RVOT)-V(HB) and QRS-V(HB) intervals could differentiate left from right OT origins of VA with high sensitivity and negative predictive values
Importance of Clinical and Echocardiographic Hemodynamic Assessment in Chronic Pulmonary Embolism
We describe a 42-year-old man presenting to the emergency department with cardiogenic shock. He had a prior history of acute pulmonary embolism (PE), and had been on anticoagulation for 2 years. Although computed tomographic pulmonary angiography performed at the emergency department showed no change in the extent of PE and did not support a role of surgical treatment, pulmonary embolectomy was recommended by attending physician based on clinical and echocardiographic hemodynamic findings like unstable vital sign and markedly enlarged right ventricle with severely depressed systolic function. Surgery confirmed the presence of fresh thrombi. After surgery, hemodynamic status was progressively improved, but the patient died due to pneumonia and pulmonary hemorrhage
Recurrent Syncope Triggered by Temporal Lobe Epilepsy: Ictal Bradycardia Syndrome
Ictal asystole is potentially lethal, and known to originate from the involvement of limbic autonomic regions. Appropriate treatment must include an antiepileptic drug and the implantation of a pacemaker. We report the case of a 54-year-old male with recurrent syncope secondary to ictal asystole triggered by temporal lobe epilepsy. This was confirmed by combined Holter and video-electroencephalogram monitoring
Neurotrophic interactions between neurons and astrocytes following AAV1-Rheb(S16H) transduction in the hippocampus in vivo
Background and Purpose: We recently reported that AAV1-Rheb(S16H) transduction could protect hippocampal neurons through the induction of brain-derived neurotrophic factor (BDNF) in the rat hippocampus in vivo. It is still unclear how neuronal BDNF produced by AAV1-Rheb(S16H) transduction induces neuroprotective effects in the hippocampus and whether its up-regulation contributes to the enhance of a neuroprotective system in the adult brain. Experimental Approach: To determine the presence of a neuroprotective system in the hippocampus of patients with Alzheimer's disease (AD), we examined the levels of glial fibrillary acidic protein, BDNF and ciliary neurotrophic factor (CNTF) and their receptors, tropomyocin receptor kinase B (TrkB) and CNTF receptor α(CNTFRα), in the hippocampus of AD patients. We also determined whether AAV1-Rheb(S16H) transduction stimulates astroglial activation and whether reactive astrocytes contribute to neuroprotection in models of hippocampal neurotoxicity in vivo and in vitro. Key Results: AD patients may have a potential neuroprotective system, demonstrated by increased levels of full-length TrkB and CNTFRα in the hippocampus. Further AAV1-Rheb(S16H) transduction induced sustained increases in the levels of full-length TrkB and CNTFRα in reactive astrocytes and hippocampal neurons. Moreover, neuronal BDNF produced by Rheb(S16H) transduction of hippocampal neurons induced reactive astrocytes, resulting in CNTF production through the activation of astrocytic TrkB and the up-regulation of neuronal BDNF and astrocytic CNTF which had synergistic effects on the survival of hippocampal neurons in vivo. Conclusions and Implications: The results demonstrated that Rheb(S16H) transduction of hippocampal neurons could strengthen the neuroprotective system and this intensified system may have a therapeutic value against neurodegeneration in the adult brain. © 2019 The Authors. British Journal of Pharmacology published by John Wiley & Sons Ltd on behalf of British Pharmacological Society1
The Utility of Multi-detector Row Spiral CT for Detection of Coronary Artery Stenoses
Contrast-enhanced multi-detector row spiral computed tomography (MDCT) was introduced as a promising noninvasive method for vascular imaging. This study examined the accuracy of this technique for detecting significant coronary artery stenoses. Both MDCT(Sensation 16, Siemens, Germany, 12 × 0.75 mm collimation and 0.42 sec rotation speed, 120 kV, 500 effective mA, and 2.7 mm/rotation table-feed) and invasive coronary angiography (CAG) were performed on 61 patients (mean age 59.2 ± 10, 44 men) who were suspected of having coronary artery disease. All patients were treated with atenolol (25 - 50 mg) prior to imaging and the heart rate was maintained below 65 beats per minutes during image acquisition. The images were reconstructed in the diastole around TI - 400 ms with a 0.5 mm increment and a 1.0 mm thickness. All coronary arteries with a diameter of 2.0 mm or more were assessed for the presence of a stenosis (> 50% luminal narrowing). Two independent radiologists who were unaware of the results of the invasive CAG evaluated the MDCT data, and the results were compared with those from the invasive CAG (interval 1- 27, mean 11 days). An evaluation of the CT coronary angiogram (CTCA) was possible in 58 of the 61 patients (95%). Image acquisition of the major coronary arteries including the left main trunk was available in 229 out of 244 arteries. Invasive CAG showed that 35 out of 58 patients had significant coronary artery stenoses by. patient analysis of those who could be evaluated showed that CT coronary angiography correctly classified 30 out of 35 patients as having at least 1 coronary stenosis (sensitivity 85.7%, specificity 91.3%, positive predictive value 93.8%, negative predictive value 80.8%). By analyzing each coronary artery, CAG found 62 stenotic coronary arteries in the 229 coronary arteries that could be evaluated. MDCT correctly detected 50 out of 62 stenotic coronary arteries and an absence of stenosis was correctly identified in 156 out of 167 normal coronary arteries (sensitivity 80.6%, specificity 93.4%, positive predictive value 81.9%, negative predictive value 92.8%). The non-invasive technique of MDCT for examining the coronary artery appears to be a useful method for detecting coronary artery stenoses with a high accuracy particularly with the proximal portion and large arteries
- …