452 research outputs found

    An Image Retrieval System Based on the Color Complexity of Images

    Get PDF
    The fuzzy color histogram (FCH) spreads each pixel's total membership value to all histogram bins based on their color similarity. The FCH is insensitive to quantization errors. However, the FCH can state only the global properties of an image rather than the local properties. For example, it cannot depict the color complexity of an image. To characterize the color complexity of an image, this paper presents two image features -- the color variances among adjacent segments (CVAAS) and the color variances of the pixels within an identical segment (CVPWIS). Both features can explain not only the color complexity but also the principal pixel colors of an image. Experimental results show that the CVAAS and CVPWIS based image retrieval systems can provide a high accuracy rate for finding out the database images that satisfy the users' requirement. Moreover, both systems can also resist the scale variances of images as well as the shift and rotation variances of segments in images

    An Automatic Indirect Immunofluorescence Cell Segmentation System

    Get PDF
    Indirect immunofluorescence (IIF) with HEp-2 cells has been used for the detection of antinuclear autoantibodies (ANA) in systemic autoimmune diseases. The ANA testing allows us to scan a broad range of autoantibody entities and to describe them by distinct fluorescence patterns. Automatic inspection for fluorescence patterns in an IIF image can assist physicians, without relevant experience, in making correct diagnosis. How to segment the cells from an IIF image is essential in developing an automatic inspection system for ANA testing. This paper focuses on the cell detection and segmentation; an efficient method is proposed for automatically detecting the cells with fluorescence pattern in an IIF image. Cell culture is a process in which cells grow under control. Cell counting technology plays an important role in measuring the cell density in a culture tank. Moreover, assessing medium suitability, determining population doubling times, and monitoring cell growth in cultures all require a means of quantifying cell population. The proposed method also can be used to count the cells from an image taken under a fluorescence microscope

    BN-embedded monolayer graphene with tunable electronic and topological properties

    Full text link
    Finding an effective and controllable way to create a sizable energy gap in graphene-based systems has been a challenging topic of intensive research. We propose that the hybrid of boron nitride and graphene (h-BNC) at low BN doping serves as an ideal platform for band-gap engineering and valleytronic applications. We report a systematic first-principles study of the atomic configurations and band gap opening for energetically favorable BN patches embedded in graphene. Based on first-principles calculations, we construct a tight-binding model to simulate general doping configurations in large supercells. Unexpectedly, the calculations find a linear dependence of the band gap on the effective BN concentration at low doping, arising from an induced effective on-site energy difference at the two C sublattices as they are substituted by B and N dopants alternately. The significant and tunable band gap of a few hundred meVs, with preserved topological properties of graphene and feasible sample preparation in the laboratory, presents great opportunities to realize valley physics applications in graphene systems at room temperature

    Effectiveness of influenza vaccination in patients with end-stage renal disease receiving hemodialysis: a population-based study.

    Get PDF
    BackgroundLittle is known on the effectiveness of influenza vaccine in ESRD patients. This study compared the incidence of hospitalization, morbidity, and mortality in end-stage renal disease (ESRD) patients undergoing hemodialysis (HD) between cohorts with and without influenza vaccination.MethodsWe used the insurance claims data from 1998 to 2009 in Taiwan to determine the incidence of these events within one year after influenza vaccination in the vaccine (N = 831) and the non-vaccine (N = 3187) cohorts. The vaccine cohort to the non-vaccine cohort incidence rate ratio and hazard ratio (HR) of morbidities and mortality were measured.ResultsThe age-specific analysis showed that the elderly in the vaccine cohort had lower hospitalization rate (100.8 vs. 133.9 per 100 person-years), contributing to an overall HR of 0.81 (95% confidence interval (CI) 0.72-0.90). The vaccine cohort also had an adjusted HR of 0.85 [95% CI 0.75-0.96] for heart disease. The corresponding incidence of pneumonia and influenza was 22.4 versus 17.2 per 100 person-years, but with an adjusted HR of 0.80 (95% CI 0.64-1.02). The vaccine cohort had lowered risks than the non-vaccine cohort for intensive care unit (ICU) admission (adjusted HR 0.20, 95% CI 0.12-0.33) and mortality (adjusted HR 0.50, 95% CI 0.41-0.60). The time-dependent Cox model revealed an overall adjusted HR for mortality of 0.30 (95% CI 0.26-0.35) after counting vaccination for multi-years.ConclusionsESRD patients with HD receiving the influenza vaccination could have reduced risks of pneumonia/influenza and other morbidities, ICU stay, hospitalization and death, particularly for the elderly

    Effects of PTFE micro-particles on the fiber-matrix interface of polyoxymethylene/glass fiber/polytetrafluoroethylene composites

    Get PDF
    Reinforcing polyoxymethylene (POM) with glass fibers (GF) enhances its mechanical properties, but at the expense of tribological performance. Formation of a transfer film to facilitate tribo-contact is compromised due to the abrasiveness of GF. As a solid lubricant, for example, polytetrafluoroethylene (PTFE) significantly improves friction and wear resistance. The effects of chemically etched PTFE micro-particles on the fiber-matrix interface of POM/GF/PTFE composites have not been systematically characterized. The aim of this study is to investigate their tribological performance as a function of micro-PTFE blended by weight percentage. Samples were prepared by different compositions of PTFE (0, 1.7, 4.0, 9.5, 15.0 and 17.3 wt.%). The surface energy of PTFE micro-particles was increased by etching for 10 min using sodium naphthalene salt in tetrahydrofuran. Tribological performance was characterized through simultaneous acquisition of the coefficient of friction and wear loss on a reciprocating test rig in accordance to Procedure A of ASTM G133-95. Friction and wear resistance improved as the micro-PTFE weight ratio was increased. Morphology analysis of worn surfaces showed transfer film formation, encapsulating the abrasive GF. Energy dispersive X-ray spectroscopy (EDS) revealed increasing PTFE concentration from the GF surface interface region (0.5, 1.0, 1.5, 2.0, 2.5 µm)

    Potential Osteoporosis Recovery by Deep Sea Water through Bone Regeneration in SAMP8 Mice

    Get PDF
    The aim of this study is to examine the therapeutic potential of deep sea water (DSW) on osteoporosis. Previously, we have established the ovariectomized senescence-accelerated mice (OVX-SAMP8) and demonstrated strong recovery of osteoporosis by stem cell and platelet-rich plasma (PRP). Deep sea water at hardness (HD) 1000 showed significant increase in proliferation of osteoblastic cell (MC3T3) by MTT assay. For in vivo animal study, bone mineral density (BMD) was strongly enhanced followed by the significantly increased trabecular numbers through micro-CT examination after a 4-month deep sea water treatment, and biochemistry analysis showed that serum alkaline phosphatase (ALP) activity was decreased. For stage-specific osteogenesis, bone marrow-derived stromal cells (BMSCs) were harvested and examined. Deep sea water-treated BMSCs showed stronger osteogenic differentiation such as BMP2, RUNX2, OPN, and OCN, and enhanced colony forming abilities, compared to the control group. Interestingly, most untreated OVX-SAMP8 mice died around 10 months; however, approximately 57% of DSW-treated groups lived up to 16.6 months, a life expectancy similar to the previously reported life expectancy for SAMR1 24 months. The results demonstrated the regenerative potentials of deep sea water on osteogenesis, showing that deep sea water could potentially be applied in osteoporosis therapy as a complementary and alternative medicine (CAM)

    Outcomes of patients with rodenticide poisoning at a far east poison center

    Get PDF
    BACKGROUND: Rodenticide poisoning remains a major public health problem in Asian countries. Nevertheless, very few data are available in world literature regarding the outcomes of these patients. Therefore, the purpose of this study was to investigate the clinical outcomes of rodenticide poisonings in our hospital and to compare these data with published reports from other international poison centers. FINDINGS: We retrospectively examined the records of 20 patients with rodenticide poisoning (8 brodifacoum, 12 bromadiolone) who were referred to Chang Gung Memorial Hospital between 2000 and 2011. It was found that most of the rodenticide patients were middle-aged adults. Both genders were equally affected and many patients had a past history of major depressive disorder or schizophrenia. Nevertheless, patients with bromadiolone were referred significantly sooner than patients with brodifacoum poisoning (0.1 ± 0.1 versus 5.5 ± 10.5, P < 0.001). Furthermore, it was found that patients with brodifacoum suffered higher incidences of ecchymosis (50.0% versus 0%, P = 0.006) and hematuria (50.0% versus 0%, P = 0.006) than patients with bromadiolone poisoning. Laboratory analysis also demonstrated a poorer hemostatic profile of patients with brodifacoum [prothrombin time (PT), international normalized ratio (INR), 4.3 ± 4.8 versus 1.0 ± 0.1, P = 0.032; PT prolongation, 50.0% versus 0%, P = 0.006; activated partial thromboplastin time (aPTT) prolongation, 50.0% versus 0%, P = 0.006] than patients with bromadiolone poisoning. At the end of analysis, no patient died of the poisoning. CONCLUSION: The favorable outcome (zero mortality rate) is comparable to the published reports from other international poison centers. Further studies are warranted

    Novel Ultrasonographic Fatty Liver Indicator Can Predict Hepatitis in Children With Non-alcoholic Fatty Liver Disease

    Get PDF
    Background: Childhood non-alcoholic fatty liver disease (NAFLD) is a public health issue worldwide. To date, liver biopsy remains the gold standard for diagnosing the severity of NAFLD. However, this invasive procedure might contribute to complications. Owing to this reason, a good non-invasive tool to estimate NAFLD in children is urgently needed. We sought to investigate whether a non-invasive semi-quantitative ultrasonographic fatty liver indicator (US-FLI) can estimate NAFLD in children.Methods: Children aged between 10 and 18 years were enrolled prospectively. Abdominal ultrasonography was performed by a single experienced pediatric gastroenterologist and the non-invasive semi-quantitative US-FLI score were used. Patients were diagnosed with NAFLD if they had a US-FLI score ≥2. The anthropometric measures, obesity-related biochemical results, and levels of tumor necrosis factor-α, interleukin-6, caspase-cleaved cytokeratin fragment of cytokeratin 18 (M30), and adiponectin were also checked.Results: Overall, 117 children aged 10–18 years were enrolled. The anthropometric measures and obesity-related biochemical parameters (hsCRP, triglyceride, uric acid, AST, ALT, γ-GT, homeostatic model assessment insulin resistance (HOMA-IR), and M30) were significantly higher in the obesity group than in the non-obesity group (p &lt; 0.05). Similarly, the US-FLI score was significantly higher in the obesity group than that in the non-obesity group (p &lt; 0.001). Multiple linear regression showed that the US-FLI score was significantly associated with the waist-to-height ratio, uric acid, adiponectin, and M30 levels (all p &lt; 0.05) in children with obesity. The US-FLI score ≥6 was the optimal cut-off point for predicting the hepatitis in children with NAFLD. The area under the receiver operating characteristic curve was 0.710 (95% CI: 0.572–0.847; p = 0.005).Conclusions: The non-invasive US-FLI score can predict hepatitis in children with NAFLD without mandatory liver biopsy. Moreover, the waist-to-height ratio, uric acid, adiponectin, and M30 levels were significantly associated with US-FLI score in children with obesity
    corecore