690 research outputs found

    Extraction frequencies at a university orthodontic clinic in the 21st century: Demographic and diagnostic factors affecting the likelihood of extraction

    Get PDF
    The aims of this study were 1) to report contemporary orthodontic extraction frequencies at a university center and 2) to investigate what patient-related factors might influence the likelihood of extraction

    In-vivo force decay of nickel-titanium closed-coil springs

    Get PDF
    Nickel-titanium (NiTi) closed coil springs are purported to deliver constant forces over extended ranges of activation and working times. In vivo studies supporting this claim are limited. The objective of this study is to evaluate changes in force decay properties of NiTi closed coil springs after clinical use

    Biomechanical characterization of the periodontal ligament: Orthodontic tooth movement

    Get PDF
    To quantify the biomechanical properties of the bovine periodontal ligament (PDL) in postmortem sections and to apply these properties to study orthodontic tooth intrusion using finite element analysis (FEA). We hypothesized that PDL’s property inherited heterogeneous (anatomical dependency) and nonlinear stress-strain behavior that could aid FEA to delineate force vectors with various rectangular archwires

    An investigation of siloxane cross-linked hydroxyapatite–gelatin/copolymer composites for potential orthopedic applications

    Get PDF
    Causes of bone deficiency are numerous, but biomimetic alloplastic grafts provide an alternative to repair tissue naturally. Previously, a hydroxyapatite-gelatin modified siloxane (HAp-Gemosil) composite was prepared by cross-linking (N, N′-bis[(3-trimethoxysilyl)propyl]ethylene diamine (enTMOS) around the HAp-Gel nanocomposite particles, to mimic the natural composition and properties of bone. However, the tensile strength remained too low for many orthopedic applications. It was hypothesized that incorporating a polymer chain into the composite could help improve long range interaction. Furthermore, designing this polymer to interact with the enTMOS siloxane cross-linked matrix would provide improved adhesion between the polymer and the ceramic composite, and improve mechanical properties. To this end, copolymers of L-Lactide (LLA), and a novel alkyne derivatized trimethylene carbonate, propargyl carbonate (PC), were synthesized. Incorporation of PC during copolymerization affects properties of copolymers such as molecular weight, Tg, and % PC incorporation. More importantly, PC monomers bear a synthetic handle, allowing copolymers to undergo post-polymerization functionalization with graft monomers to specifically tailor the properties of the final composite. For our investigation, P(LLA-co-PC) copolymers were functionalized by an azido-silane (AS) via copper catalyzed azide-alkyne cycloaddition (CuAAC) through terminal alkyne on PC monomers. The new functionalized polymer, P(LLA-co-PC)(AS) was blended with HAp-Gemosil, with the azido-silane linking the copolymer to the silsesquioxane matrix within the final composite

    Transplantation of Human Umbilical Mesenchymal Stem Cells from Wharton's Jelly after Complete Transection of the Rat Spinal Cord

    Get PDF
    BACKGROUND: Human umbilical mesenchymal stem cells (HUMSCs) isolated from Wharton's jelly of the umbilical cord can be easily obtained and processed compared with embryonic or bone marrow stem cells. These cells may be a valuable source in the repair of spinal cord injury. METHODOLOGY/PRINCIPAL FINDINGS: We examine the effects of HUMSC transplantation after complete spinal cord transection in rats. Approximately 5x10(5) HUMSCs were transplanted into the lesion site. Three groups of rats were implanted with either untreated HUMSCs (referred to as the stem cell group), or HUMSCs treated with neuronal conditioned medium (NCM) for either three days or six days (referred to as NCM-3 and NCM-6 days, respectively). The control group received no HUMSCs in the transected spinal cord. Three weeks after transplantation, significant improvements in locomotion were observed in all the three groups receiving HUMSCs (stem cell, NCM-3 and NCM-6 days groups). This recovery was accompanied by increased numbers of regenerated axons in the corticospinal tract and neurofilament-positive fibers around the lesion site. There were fewer microglia and reactive astrocytes in both the rostral and caudal stumps of the spinal cord in the stem cell group than in the control group. Transplanted HUMSCs survived for 16 weeks and produced large amounts of human neutrophil-activating protein-2, neurotrophin-3, basic fibroblast growth factor, glucocorticoid induced tumor necrosis factor receptor, and vascular endothelial growth factor receptor 3 in the host spinal cord, which may help spinal cord repair. CONCLUSIONS/SIGNIFICANCE: Transplantation of HUMSCs is beneficial to wound healing after spinal cord injury in rats

    Antidepressant-Like Activity of the Ethanolic Extract from Uncaria lanosa Wallich var. appendiculata Ridsd in the Forced Swimming Test and in the Tail Suspension Test in Mice

    Get PDF
    This study investigated the antidepressant activity of ethanolic extract of U. lanosa Wallich var. appendiculata Ridsd (ULEtOH) for two-weeks administrations by using FST and TST on mice. In order to understand the probable mechanism of antidepressant-like activity of ULEtOH in FST and TST, the researchers measured the levels of monoamines and monoamine oxidase activities in mice brain, and combined the antidepressant drugs (fluoxetine, imipramine, maprotiline, clorgyline, bupropion and ketanserin). Lastly, the researchers analyzed the content of RHY in the ULEtOH. The results showed that ULEtOH exhibited antidepressant-like activity in FST and TST in mice. ULEtOH increased the levels of 5-HT and 5-HIAA in cortex, striatum, hippocampus, and hypothalamus, the levels of NE and MHPG in cortex and hippocampus, the level of NE in striatum, and the level of DOPAC in striatum. Two-week injection of IMI, CLO, FLU and KET enhanced the antidepressant-like activity of ULEtOH. ULEtOH inhibited the activity of MAO-A. The amount of RHY in ULEtOH was 17.12 mg/g extract. Our findings support the view that ULEtOH exerts antidepressant-like activity. The antidepressant-like mechanism of ULEtOH may be related to the increase in monoamines levels in the hippocampus, cortex, striatum, and hypothalamus of mice

    Localized mechanics of dentin self-etching adhesive system

    Get PDF
    The bond strength of composite resins (CRs) to dentin is influenced by the interfacial microstructure of the hybrid layer (HL) and the resin tags (TAG). The contemporary self-etching primer adhesive systems overcame the inconvenient of the etch-and-rinse protocol. Studies, however, have demonstrated that HL thickness and TAG length vary according to the wetting time and additional use of acid-etching prior to self-etching primers. This study investigated the localized stress distribution in the HL and the dentin/adhesive interface. Two HL thicknesses (3 or 6 µm), two TAG lengths (13 or 17 µm) and two loading conditions (perpendicular and oblique-25º) were investigated by the finite element (FE) analysis. Five two-dimensional FE models (M) of a dentin specimen restored with CR (38 x 64 µm) were constructed: M1 - no HL and no TAG; M2 - 3 µm of HL and 13 µm of TAG; M3 - 3 µm of HL and 17 µm of TAG; M4 - 6 µm of HL and 13 µm of TAG; and M5 - 6 µm of HL and 17 µm of TAG. Two distributed loadings (L) (20N) were applied on CR surface: L1 - perpendicular, and L2 - oblique (25º). Fixed interfacial conditions were assigned on the border of the dentin specimen. Ansys 10.0 (Ansys®, Houston, PA, USA) software was used to calculate the stress fields. The peak of von Mises (sigmavM) and maximum principal stress (sigmamax) was higher in L2 than in L1. Microstructures (HL and TAG) had no effect on local stresses for L1. Decreasing HL decreased sigmavM and sigmamax in all structures for L2, but the TAG length had influence only on the peributular dentin. The thickness of HL had more influence on the sigmavM and sigmamax than TAG length. The peritubular dentin and its adjacent structures showed the highest sigmavM and sigmamax, mainly in the oblique loading

    Comparison of postoperative changes in the distal and proximal segments between conventional and sliding mini-plate fixation following mandibular setback

    Get PDF
    The purpose of the present study was to evaluate the postoperative three-dimensional (3D) changes in the proximal segments after mandibular setback sagittal split ramus osteotomy and to compare the changes between the conventional mini-plate fixation and semi-rigid sliding plate fixation

    Comparison of Cortical Bone Trajectory to Pedicle-Based Dynamic Stabilization: An Analysis of 291 Patients

    Get PDF
    Objective Pedicle-based dynamic stabilization (DS) has gained popularity outside of America. Although pedicle screw (PS) loosening has always been a concern, it is reportedly innocuous. Cortical bone trajectory (CBT) screw is an emerging option with less invasiveness and similar effectiveness to PS in short-segment lumbar fusion. This study aimed to verify the use of CBT for DS by comparing the outcomes between pedicle- and CBT-based DS. Methods Consecutive patients with lumbar spondylosis or low-grade spondylolisthesis who underwent 1- or 2-level DS between L3–5 with a minimum follow-up of 24 months were reviewed. Screw loosening was determined by computed tomography and the incidences were compared. Results A total of 291 patients who underwent Dynesys DS (235 pedicle- and 56 CBT-based, respectively) were compared. The demographics and preoperative conditions were similar. All the clinical outcomes improved at 24-month postoperation, while the CBT-based group had less operation time and blood loss than the pedicle-based group. The rates of screw loosening were lower in the CBT-based (5.4% per screw and 12.5% per patient) than the pedicle-based group (9% per screw and 26.4% per patient). Furthermore, there were no differences in the clinical outcomes and complication profiles. Conclusion The CBT-based DS for 1- or 2-level lumbar degeneration demonstrated equivalent clinical improvement as the pedicle-based DS. The adaption of CBT-based screws for DS could be a less invasive approach (shorter operation time and less blood loss), with lower chances of screw loosening than the conventional PS-based DS
    corecore