273 research outputs found

    Ion traps fabricated in a CMOS foundry

    Get PDF
    We demonstrate trapping in a surface-electrode ion trap fabricated in a 90-nm CMOS (complementary metal-oxide-semiconductor) foundry process utilizing the top metal layer of the process for the trap electrodes. The process includes doped active regions and metal interconnect layers, allowing for co-fabrication of standard CMOS circuitry as well as devices for optical control and measurement. With one of the interconnect layers defining a ground plane between the trap electrode layer and the p-type doped silicon substrate, ion loading is robust and trapping is stable. We measure a motional heating rate comparable to those seen in surface-electrode traps of similar size. This is the first demonstration of scalable quantum computing hardware, in any modality, utilizing a commercial CMOS process, and it opens the door to integration and co-fabrication of electronics and photonics for large-scale quantum processing in trapped-ion arrays.Comment: 4 pages, 3 figure

    Precision measurement of the 5 2S1/2 - 4 2D5/2 quadrupole transition isotope shift between 88Sr+ and 86Sr+

    Full text link
    We have measured the isotope shift of the narrow quadrupole-allowed 5 2S1/2 - 4 2D5/2 transition in 86Sr+ relative to the most abundant isotope 88Sr+. This was accomplished using high-resolution laser spectroscopy of individual trapped ions, and the measured shift is Delta-nu_meas^(88,86) = 570.281(4) MHz. We have also tested a recently developed and successful method for ab-initio calculation of isotope shifts in alkali-like atomic systems against this measurement, and our initial result of Delta-nu_calc^(88,86) = 457(28) MHz is also presented. To our knowledge, this is the first high precision measurement and calculation of that isotope shift. While the measurement and the calculation are in broad agreement, there is a clear discrepancy between them, and we believe that the specific mass shift was underestimated in our calculation. Our measurement provides a stringent test for further refinements of theoretical isotope shift calculation methods for atomic systems with a single valence electron

    Fundamental phenomena on fuel decomposition and boundary layer combustion processes with applications to hybrid rocket motors

    Get PDF
    An experimental study on the fundamental processes involved in fuel decomposition and boundary layer combustion in hybrid rocket motors is being conducted at the High Pressure Combustion Laboratory of the Pennsylvania State University. This research should provide an engineering technology base for development of large scale hybrid rocket motors as well as a fundamental understanding of the complex processes involved in hybrid propulsion. A high pressure slab motor has been designed for conducting experimental investigations. Oxidizer (LOX or GOX) is injected through the head-end over a solid fuel (HTPB) surface. Experiments using fuels supplied by NASA designated industrial companies will also be conducted. The study focuses on the following areas: measurement and observation of solid fuel burning with LOX or GOX, correlation of solid fuel regression rate with operating conditions, measurement of flame temperature and radical species concentrations, determination of the solid fuel subsurface temperature profile, and utilization of experimental data for validation of a companion theoretical study also being conducted at PSU

    High fidelity transport of trapped-ion qubits through an X-junction trap array

    Full text link
    We report reliable transport of 9Be+ ions through a 2-D trap array that includes a separate loading/reservoir zone and an "X-junction". During transport the ion's kinetic energy in its local well increases by only a few motional quanta and internal-state coherences are preserved. We also examine two sources of energy gain during transport: a particular radio-frequency (RF) noise heating mechanism and digital sampling noise. Such studies are important to achieve scaling in a trapped-ion quantum information processor.Comment: 4 pages, 3 figures Updated to reduce manuscript to four pages. Some non-essential information was removed, including some waveform information and more detailed information on the tra

    Electron impact ionization loading of a surface electrode ion trap

    Full text link
    We demonstrate a method for loading surface electrode ion traps by electron impact ionization. The method relies on the property of surface electrode geometries that the trap depth can be increased at the cost of more micromotion. By introducing a buffer gas, we can counteract the rf heating assocated with the micromotion and benefit from the larger trap depth. After an initial loading of the trap, standard compensation techniques can be used to cancel the stray fields resulting from charged dielectric and allow for the loading of the trap at ultra-high vacuum.Comment: 4 pages, 5 eps figures. Shift in focus, minor correction

    T-junction ion trap array for two-dimensional ion shuttling, storage and manipulation

    Get PDF
    We demonstrate a two-dimensional 11-zone ion trap array, where individual laser-cooled atomic ions are stored, separated, shuttled, and swapped. The trap geometry consists of two linear rf ion trap sections that are joined at a 90 degree angle to form a T-shaped structure. We shuttle a single ion around the corners of the T-junction and swap the positions of two crystallized ions using voltage sequences designed to accommodate the nontrivial electrical potential near the junction. Full two-dimensional control of multiple ions demonstrated in this system may be crucial for the realization of scalable ion trap quantum computation and the implementation of quantum networks.Comment: 3 pages, 5 figure
    corecore