16 research outputs found

    Monitoring, management, and outcome of hypotension in Intensive Care Unit patients, an international survey of the European Society of Intensive Care Medicine

    Get PDF
    INTRODUCTION: Hypotension in the ICU is common, yet management is challenging and variable. Insight in management by ICU physicians and nurses may improve patient care and guide future hypotension treatment trials and guidelines. METHODS: We conducted an international survey among ICU personnel to provide insight in monitoring, management, and perceived consequences of hypotension. RESULTS: Out of 1464 respondents, 1197 (81.7%) were included (928 physicians (77.5%) and 269 nurses (22.5%)). The majority indicated that hypotension is underdiagnosed (55.4%) and largely preventable (58.8%). Nurses are primarily in charge of monitoring changes in blood pressure, physicians are in charge of hypotension treatment. Balanced crystalloids, dobutamine, norepinephrine, and Trendelenburg position were the most frequently reported fluid, inotrope, vasopressor, and positional maneuver used to treat hypotension. Reported complications believed to be related to hypotension were AKI and myocardial injury. Most ICUs do not have a specific hypotension treatment guideline or protocol (70.6%), but the majority would like to have one in the future (58.1%). CONCLUSIONS: Both physicians and nurses report that hypotension in ICU patients is underdiagnosed, preventable, and believe that hypotension influences morbidity. Hypotension management is generally not protocolized, but the majority of respondents would like to have a specific hypotension management protocol

    Definition and incidence of hypotension in intensive care unit patients, an international survey of the European Society of Intensive Care Medicine

    Get PDF
    Introduction: Although hypotension in ICU patients is associated with adverse outcome, currently used definitions are unknown and no universally accepted definition exists. Methods: We conducted an international, peer-reviewed survey among ICU physicians and nurses to provide insight in currently used definitions, estimations of incidence, and duration of hypotension. Results: Out of 1394 respondents (1055 physicians (76%) and 339 nurses (24%)), 1207 (82%) completed the questionnaire. In all patient categories, hypotension definitions were predominantly based on an absolute MAP of 65 mmHg, except for the neuro(trauma) category (75 mmHg, p &lt; 0.001), without differences between answers from physicians and nurses. Hypotension incidence was estimated at 55%, and time per day spent in hypotension at 15%, both with nurses reporting higher percentages than physicians (estimated mean difference 5%, p = 0.01; and 4%, p &lt; 0.001). Conclusions: An absolute MAP threshold of 65 mmHg is most frequently used to define hypotension in ICU patients. In neuro(trauma) patients a higher threshold was reported. The majority of ICU patients are estimated to endure hypotension during their ICU admission for a considerable amount of time, with nurses reporting a higher estimated incidence and time spent in hypotension than physicians.</p

    Multi-site and multi-depth near-infrared spectroscopy in a model of simulated (central) hypovolemia: lower body negative pressure

    Get PDF
    Purpose: To test the hypothesis that the sensitivity of near-infrared spectroscopy (NIRS) in reflecting the degree of (compensated) hypovolemia would be affected by the application site and probing depth. We simultaneously applied multi-site (thenar and forearm) and multi-depth (15-2.5 and 25-2.5 mm probe distance) NIRS in a model of simulated hypovolemia: lower body negative pressure (LBNP). Methods: The study group comprised 24 healthy male volunteers who were subjected to an LBNP protocol in which a baseline period of 30 min was followed by a step-wise manipulation of negative pressure in the following steps: 0, -20, -40, -60, -80 and -100 mmHg. Stroke volume and heart rate were measured using volume-clamp finger plethysmography. Two multi-depth NIRS devices were used to measure tissue oxygen saturation (StO2) and tissue hemoglobin index (THI) continuously in the thenar and the forearm. To monitor the shift of blood volume towards the lower extremities, calf THI was measured by single-depth NIRS. Results: The main findings were that the application of LBNP resulted in a significant reduction in stroke volume which was accompanied by a reduction in forearm StO2 and THI. Conclusions: NIRS can be used to detect changes in StO2 and THI consequent upon central hypovolemia. Forearm NIRS measurements reflect hypovolemia more sensitively than thenar NIRS measurements. The sensitivity of these NIRS measurements does not depend on NIRS probing depth. The LBNP-induced shift in blood volume is reflected by a decreased THI in the forearm and an increased THI in the calf

    目次

    Get PDF
    Cardiopulmonary interactions induced by mechanical ventilation are complex and only partly understood. Applied tidal volumes and/or airway pressures largely mediate changes in right ventricular preload and afterload. Effects on left ventricular function are mostly secondary to changes in right ventricular loading conditions. It is imperative to dissect the several causes of haemodynamic compromise during mechanical ventilation as undiagnosed ventricular dysfunction may contribute to morbidity and mortalit

    Basic concepts of fluid responsiveness

    Get PDF
    Predicting fluid responsiveness, the response of stroke volume to fluid loading, is a relatively novel concept that aims to optimise circulation, and as such organ perfusion, while avoiding futile and potentially deleterious fluid administrations in critically ill patients. Dynamic parameters have shown to be superior in predicting the response to fluid loading compared with static cardiac filling pressures. However, in routine clinical practice the conditions necessary for dynamic parameters to predict fluid responsiveness are frequently not met. Passive leg raising as a means to alter biventricular preload in combination with subsequent measurement of the change in stroke volume can provide a fast and accurate way to guide fluid management in a broad population of critically ill patient

    Ventilator-induced central venous pressure variation can predict fluid responsiveness in post-operative cardiac surgery patients

    No full text
    Ventilator-induced dynamic hemodynamic parameters such as stroke volume variation (SVV) and pulse pressure variation (PPV) have been shown to predict fluid responsiveness in contrast to static hemodynamic parameters such as central venous pressure (CVP). We hypothesized that the ventilator-induced central venous pressure variation (CVPV) could predict fluid responsiveness. Twenty-two elective cardiac surgery patients were studied post-operatively on the intensive care unit during mechanical ventilation with tidal volumes of 6-8 ml/kg without spontaneous breathing efforts or cardiac arrhythmia. Before and after administration of 500mL hydroxyethyl starch, SVV and PPV were measured using pulse contour analysis by modified Modelflow(®) , while CVP was obtained from a central venous catheter positioned in the superior vena cava. CVPV was calculated as 100 × (CVPmax -CVPmin )/[(CVPmax + CVPmin) /2]. Nineteen patients (86%) were fluid responders defined as an increase in cardiac output of ≥ 15% after fluid administration. CVPV decreased upon fluid loading in responders, but not in non-responders. Baseline CVP values showed no correlation with a change in cardiac output in contrast to baseline SVV (r = 0.60, P = 0.003), PPV (r = 0.58, P = 0.005), and CVPV (r = 0.63, P = 0.002). Baseline values of SVV > 9% and PPV > 8% could predict fluid responsiveness with a sensitivity of 89% and 95%, respectively, both with a specificity of 100%. Baseline CVPV could identify all fluid responders and non-responders correctly at a cut-off value of 12%. There was no difference between the area under the receiver operating characteristic curves of SVV, PPV, and CVPV. The use of ventilator-induced CVPV could predict fluid responsiveness similar to SVV and PPV in post-operative cardiac surgery patient

    Monitoring, management, and outcome of hypotension in Intensive Care Unit patients, an international survey of the European Society of Intensive Care Medicine

    No full text
    Introduction: Hypotension in the ICU is common, yet management is challenging and variable. Insight in management by ICU physicians and nurses may improve patient care and guide future hypotension treatment trials and guidelines. Methods: We conducted an international survey among ICU personnel to provide insight in monitoring, management, and perceived consequences of hypotension. Results: Out of 1464 respondents, 1197 (81.7%) were included (928 physicians (77.5%) and 269 nurses (22.5%)). The majority indicated that hypotension is underdiagnosed (55.4%) and largely preventable (58.8%). Nurses are primarily in charge of monitoring changes in blood pressure, physicians are in charge of hypotension treatment. Balanced crystalloids, dobutamine, norepinephrine, and Trendelenburg position were the most frequently reported fluid, inotrope, vasopressor, and positional maneuver used to treat hypotension. Reported complications believed to be related to hypotension were AKI and myocardial injury. Most ICUs do not have a specific hypotension treatment guideline or protocol (70.6%), but the majority would like to have one in the future (58.1%). Conclusions: Both physicians and nurses report that hypotension in ICU patients is underdiagnosed, preventable, and believe that hypotension influences morbidity. Hypotension management is generally not protocolized, but the majority of respondents would like to have a specific hypotension management protocol
    corecore