10,000 research outputs found

    Q-enhanced fold-and-bond MEMS inductors

    Get PDF
    This work presents a novel coil fabrication technology to enhance quality factor (Q factor) of microfabricated inductors for implanted medical wireless sensing and data/power transfer applications. Using parylene as a flexible thin-film device substrate, a post-microfabrication substrate folding-and-bonding method is developed to effectively increase the metal thickness of the surface-micromachined inductors, resulting in their lower self-resistance so their higher quality factor. One-fold-and-bond coils are successfully demonstrated as an example to verify the feasibility of the fabrication technology with measurement results in good agreements with device simulation. Depending on target specifications, multiple substrate folding-and-bonding can be extensively implemented to facilitate further improved electrical characteristics of the coils from single fabrication batch. Such Q-enhanced inductors can be broadly utilized with great potentials in flexible integrated wireless devices/systems for intraocular prostheses and other biomedical implants

    Noninvasive prediction of Blood Lactate through a machine learning-based approach.

    Get PDF
    We hypothesized that blood lactate concentration([Lac]blood) is a function of cardiopulmonary variables, exercise intensity and some anthropometric elements during aerobic exercise. This investigation aimed to establish a mathematical model to estimate [Lac]blood noninvasively during constant work rate (CWR) exercise of various intensities. 31 healthy participants were recruited and each underwent 4 cardiopulmonary exercise tests: one incremental and three CWR tests (low: 35% of peak work rate for 15 min, moderate: 60% 10 min and high: 90% 4 min). At the end of each CWR test, venous blood was sampled to determine [Lac]blood. 31 trios of CWR tests were employed to construct the mathematical model, which utilized exponential regression combined with Taylor expansion. Good fitting was achieved when the conditions of low and moderate intensity were put in one model; high-intensity in another. Standard deviation of fitting error in the former condition is 0.52; in the latter is 1.82 mmol/liter. Weighting analysis demonstrated that, besides heart rate, respiratory variables are required in the estimation of [Lac]blood in the model of low/moderate intensity. In conclusion, by measuring noninvasive cardio-respiratory parameters, [Lac]blood during CWR exercise can be determined with good accuracy. This should have application in endurance training and future exercise industry

    iLoc-Euk: A Multi-Label Classifier for Predicting the Subcellular Localization of Singleplex and Multiplex Eukaryotic Proteins

    Get PDF
    Predicting protein subcellular localization is an important and difficult problem, particularly when query proteins may have the multiplex character, i.e., simultaneously exist at, or move between, two or more different subcellular location sites. Most of the existing protein subcellular location predictor can only be used to deal with the single-location or “singleplex” proteins. Actually, multiple-location or “multiplex” proteins should not be ignored because they usually posses some unique biological functions worthy of our special notice. By introducing the “multi-labeled learning” and “accumulation-layer scale”, a new predictor, called iLoc-Euk, has been developed that can be used to deal with the systems containing both singleplex and multiplex proteins. As a demonstration, the jackknife cross-validation was performed with iLoc-Euk on a benchmark dataset of eukaryotic proteins classified into the following 22 location sites: (1) acrosome, (2) cell membrane, (3) cell wall, (4) centriole, (5) chloroplast, (6) cyanelle, (7) cytoplasm, (8) cytoskeleton, (9) endoplasmic reticulum, (10) endosome, (11) extracellular, (12) Golgi apparatus, (13) hydrogenosome, (14) lysosome, (15) melanosome, (16) microsome (17) mitochondrion, (18) nucleus, (19) peroxisome, (20) spindle pole body, (21) synapse, and (22) vacuole, where none of proteins included has pairwise sequence identity to any other in a same subset. The overall success rate thus obtained by iLoc-Euk was 79%, which is significantly higher than that by any of the existing predictors that also have the capacity to deal with such a complicated and stringent system. As a user-friendly web-server, iLoc-Euk is freely accessible to the public at the web-site http://icpr.jci.edu.cn/bioinfo/iLoc-Euk. It is anticipated that iLoc-Euk may become a useful bioinformatics tool for Molecular Cell Biology, Proteomics, System Biology, and Drug Development Also, its novel approach will further stimulate the development of predicting other protein attributes

    A Multi-Label Classifier for Predicting the Subcellular Localization of Gram-Negative Bacterial Proteins with Both Single and Multiple Sites

    Get PDF
    Prediction of protein subcellular localization is a challenging problem, particularly when the system concerned contains both singleplex and multiplex proteins. In this paper, by introducing the “multi-label scale” and hybridizing the information of gene ontology with the sequential evolution information, a novel predictor called iLoc-Gneg is developed for predicting the subcellular localization of Gram-positive bacterial proteins with both single-location and multiple-location sites. For facilitating comparison, the same stringent benchmark dataset used to estimate the accuracy of Gneg-mPLoc was adopted to demonstrate the power of iLoc-Gneg. The dataset contains 1,392 Gram-negative bacterial proteins classified into the following eight locations: (1) cytoplasm, (2) extracellular, (3) fimbrium, (4) flagellum, (5) inner membrane, (6) nucleoid, (7) outer membrane, and (8) periplasm. Of the 1,392 proteins, 1,328 are each with only one subcellular location and the other 64 are each with two subcellular locations, but none of the proteins included has pairwise sequence identity to any other in a same subset (subcellular location). It was observed that the overall success rate by jackknife test on such a stringent benchmark dataset by iLoc-Gneg was over 91%, which is about 6% higher than that by Gneg-mPLoc. As a user-friendly web-server, iLoc-Gneg is freely accessible to the public at http://icpr.jci.edu.cn/bioinfo/iLoc-Gneg. Meanwhile, a step-by-step guide is provided on how to use the web-server to get the desired results. Furthermore, for the user's convenience, the iLoc-Gneg web-server also has the function to accept the batch job submission, which is not available in the existing version of Gneg-mPLoc web-server. It is anticipated that iLoc-Gneg may become a useful high throughput tool for Molecular Cell Biology, Proteomics, System Biology, and Drug Development
    • …
    corecore