8,079 research outputs found
Noise reduction in muon tomography for detecting high density objects
The muon tomography technique, based on multiple Coulomb scattering of cosmic
ray muons, has been proposed as a tool to detect the presence of high density
objects inside closed volumes. In this paper a new and innovative method is
presented to handle the density fluctuations (noise) of reconstructed images, a
well known problem of this technique. The effectiveness of our method is
evaluated using experimental data obtained with a muon tomography prototype
located at the Legnaro National Laboratories (LNL) of the Istituto Nazionale di
Fisica Nucleare (INFN). The results reported in this paper, obtained with real
cosmic ray data, show that with appropriate image filtering and muon momentum
classification, the muon tomography technique can detect high density
materials, such as lead, albeit surrounded by light or medium density material,
in short times. A comparison with algorithms published in literature is also
presented
An electromagnetic shashlik calorimeter with longitudinal segmentation
A novel technique for longitudinal segmentation of shashlik calorimeters has
been tested in the CERN West Area beam facility. A 25 tower very fine samplings
e.m. calorimeter has been built with vacuum photodiodes inserted in the first 8
radiation lengths to sample the initial development of the shower. Results
concerning energy resolution, impact point reconstruction and electron/pion
separation are reported.Comment: 13 pages, 12 figure
Accountants\u27 Liability to Third Parties under Bily v. Arthur Young & (and) Company: Does a Watchdog Need Protection
Update of the search for supersymmetric particles in light gravitino scenarios at = 204-208 GeV
Precision measurements of Linear Scattering Density using Muon Tomography
We demonstrate that muon tomography can be used to precisely measure the
properties of various materials. The materials which have been considered have
been extracted from an experimental blast furnace, including carbon (coke) and
iron oxides, for which measurements of the linear scattering density relative
to the mass density have been performed with an absolute precision of 10%. We
report the procedures that are used in order to obtain such precision, and a
discussion is presented to address the expected performance of the technique
when applied to heavier materials. The results we obtain do not depend on the
specific type of material considered and therefore they can be extended to any
application.Comment: 16 pages, 4 figure
- …