1,260 research outputs found
High resolution spectroscopic measurements of carbon dioxide and carbon monoxide
A modified 1.83 meter Jarrell-Ash spectrometer is reported. The instrument was double passed and achieved a resolution of 0.05 cm at 15 micrometers. An integrating voltmeter was used to optimize the available integration time. Data were obtained in the 15 micrometer and 4.3 micrometer band of CO2 and the 4.6 micrometer and 2.3 micrometer bands of CO. The data are summarized and examples of typical spectra are given. All the data are stored on IBM cards
Fundamentals of Fourier transform spectroscopy
Comprehensive review of theories, data handling, systems, and calibration in Fourier transform spectroscop
Transmissivity of carbon monoxide
The line strengths and self- and nitrogen-broadened half widths for selected lines of the 4.6 micron fundamental band of carbon monoxide were determined. The band strength determined at stp. is higher than previously reported measurements. The half widths agree well with other measurements and calculations
Application of shock tubes to transonic airfoil testing at high Reynolds numbers
Performance analysis of a gas-driven shock tube shows that transonic airfoil flows with chord Reynolds numbers of the order of 100 million can be produced, with limitations being imposed by the structural integrity of the facility or the model. A study of flow development over a simple circular arc airfoil at zero angle of attack was carried out in a shock tube at low and intermediate Reynolds numbers to assess the testing technique. Results obtained from schlieren photography and airfoil pressure measurements show that steady transonic flows similar to those produced for the same airfoil in a wind tunnel can be generated within the available testing time in a shock tube with properly contoured test section walls
Transmissivity of carbon monoxide in the 2.3 microns band region
Line strengths and self and nitrogen broadened half-widths have been determined from high resolution spectroscopic measurements of selected lines in the 2.3 micrometer band region of CO. The CO 0-2 total band strength is estimated to be 2.086 + or - 0.146 cm/1 (ATM-cm)/1 STP which is higher than most previously reported values. The line half-widths are also generally higher than those in the literature
A Fourier transform spectrometer for the measurement of atmospheric thermal radiation
Fourier transform spectrometer for measurement of atmospheric thermal radiatio
How Much DC Power Is Necessary?
Many proposals for future power systems for warships are extant. Anticipated improvements in capability, operating economy, and signature reduction may not be uniquely associated with these power systems. Alternatives are available for constructing variable speed drives and prime movers for ships with electric drives. These alternatives may open new design possibilities
Bioaccessibility Tests Accurately Estimate Bioavailability Of Lead To Quail
Hazards of soil-borne lead (Pb) to wild birds may be more accurately quantified if the bioavailability of that Pb is known. To better understand the bioavailability of Pb to birds, the authors measured blood Pb concentrations in Japanese quail (Coturnix japonica) fed diets containing Pb-contaminated soils. Relative bioavailabilities were expressed by comparison with blood Pb concentrations in quail fed a Pb acetate reference diet. Diets containing soil from 5 Pb-contaminated Superfund sites had relative bioavailabilities from 33% to 63%, with a mean of approximately 50%. Treatment of 2 of the soils with phosphorus (P) significantly reduced the bioavailability of Pb. Bioaccessibility of Pb in the test soils was then measured in 6 in vitro tests and regressed on bioavailability: the relative bioavailability leaching procedure at pH 1.5, the same test conducted at pH 2.5, the Ohio State University in vitro gastrointestinal method, the urban soil bioaccessible lead test, the modified physiologically based extraction test, and the waterfowl physiologically based extraction test. All regressions had positive slopes. Based on criteria of slope and coefficient of determination, the relative bioavailability leaching procedure at pH 2.5 and Ohio State University in vitro gastrointestinal tests performed very well. Speciation by X-ray absorption spectroscopy demonstrated that, on average, most of the Pb in the sampled soils was sorbed to minerals (30%), bound to organic matter (24%), or present as Pb sulfate (18%). Additional Pb was associated with P (chloropyromorphite, hydroxypyromorphite, and tertiary Pb phosphate) and with Pb carbonates, leadhillite (a lead sulfate carbonate hydroxide), and Pb sulfide. The formation of chloropyromorphite reduced the bioavailability of Pb, and the amendment of Pb-contaminated soils with P may be a thermodynamically favored means to sequester Pb
- …