29 research outputs found

    Computational Simulations for Aortic Coarctation: Representative Results From a Sampling of Patients

    Get PDF
    Treatments for coarctation of the aorta (CoA) can alleviate blood pressure (BP) gradients(D), but long-term morbidity still exists that can be explained by altered indices of hemodynamics and biomechanics. We introduce a technique to increase our understanding of these indices for CoA under resting and nonresting conditions, quantify their contribution to morbidity, and evaluate treatment options. Patient-specific computational fluid dynamics (CFD) models were created from imaging and BP data for one normal and four CoA patients (moderate native CoA: D12 mmHg, severe native CoA: D25 mmHg and postoperative end-to-end and end-to-side patients: D0 mmHg). Simulations incorporated vessel deformation, downstream vascular resistance and compliance. Indices including cyclic strain, time-averaged wall shear stress (TAWSS), and oscillatory shear index (OSI) were quantified. Simulations replicated resting BP and blood flow data. BP during simulated exercise for the normal patient matched reported values. Greatest exercise-induced increases in systolic BP and mean and peak DBP occurred for the moderate native CoA patient (SBP: 115 to 154 mmHg; mean and peak DBP: 31 and 73 mmHg). Cyclic strain was elevated proximal to the coarctation for native CoA patients, but reduced throughout the aorta after treatment. A greater percentage of vessels was exposed to subnormal TAWSS or elevated OSI for CoA patients. Local patterns of these indices reported to correlate with atherosclerosis in normal patients were accentuated by CoA. These results apply CFD to a range of CoA patients for the first time and provide the foundation for future progress in this area

    Computational simulations demonstrate altered wall shear stress in aortic coarctation patients previously treated by resection with end-to-end anastomosis

    Get PDF
    Background.  Atherosclerotic plaque in the descending thoracic aorta (dAo) is related to altered wall shear stress (WSS) for normal patients. Resection with end-to-end anastomosis (RWEA) is the gold standard for coarctation of the aorta (CoA) repair, but may lead to altered WSS indices that contribute to morbidity. Methods.  Computational fluid dynamics (CFD) models were created from imaging and blood pressure data for control subjects and age- and gender-matched CoA patients treated by RWEA (four males, two females, 15 ± 8 years). CFD analysis incorporated downstream vascular resistance and compliance to generate blood flow velocity, time-averaged WSS (TAWSS), and oscillatory shear index (OSI) results. These indices were quantified longitudinally and circumferentially in the dAo, and several visualization methods were used to highlight regions of potential hemodynamic susceptibility. Results.  The total dAo area exposed to subnormal TAWSS and OSI was similar between groups, but several statistically significant local differences were revealed. Control subjects experienced left-handed rotating patterns of TAWSS and OSI down the dAo. TAWSS was elevated in CoA patients near the site of residual narrowings and OSI was elevated distally, particularly along the left dAo wall. Differences in WSS indices between groups were negligible more than 5 dAo diameters distal to the aortic arch. Conclusions.  Localized differences in WSS indices within the dAo of CoA patients treated by RWEA suggest that plaque may form in unique locations influenced by the surgical repair. These regions can be visualized in familiar and intuitive ways allowing clinicians to track their contribution to morbidity in longitudinal studies

    Computational Fluid Dynamic Simulations for Determination of Ventricular Workload in Aortic Arch Obstructions

    Get PDF
    Objective The cardiac workload associated with various types of aortic obstruction was determined using computational fluid dynamic simulations. Methods Computed tomography image data were collected from 4 patients with 4 distinct types of aortic arch obstructions and 4 controls. The categorization of arch hypoplasia corresponded to the “A, B, C” nomenclature of arch interruption; a type “D” was added to represent diffuse arch hypoplasia. Measurements of the vessel diameter were compared against the normal measurements to determine the degree of narrowing. Three-dimensional models were created for each patient, and additional models were created for type A and B hypoplasia to represent 25%, 50%, and 75% diameter narrowing. The boundary conditions for the computational simulations were chosen to achieve realistic flow and pressures in the control cases. The simulations were then repeated after changing the boundary conditions to represent a range of cardiac and vascular adaptations. The resulting cardiac workload was compared with the control cases. Results Of the 4 patients investigated, 1 had aortic coarctation and 3 had aortic hypoplasia. The cardiac workload of the patients with 25% narrowing type A and B hypoplasia was not appreciably different from that of the control. When comparing the different arch obstructions, 75% type A, 50% type B, and 50% type D hypoplasia required a greater workload increase than 75% coarctation. Conclusions The present study has determined the hemodynamic significance of aortic arch obstruction using computational simulations to calculate the cardiac workload. These results suggest that all types of hypoplasia pose more of a workload challenge than coarctation with an equivalent degree of narrowing

    Evaluation of a novel Y-shaped extracardiac Fontan baffle using computational fluid dynamics

    Get PDF
    ObjectivesThe objective of this work is to evaluate the hemodynamic performance of a new Y-graft modification of the extracardiac conduit Fontan operation. The performance of the Y-graft design is compared to two designs used in current practice: a t-junction connection of the venae cavae and an offset between the inferior and superior venae cavae.MethodsThe proposed design replaces the current tube grafts used to connect the inferior vena cava to the pulmonary arteries with a Y-shaped graft. Y-graft hemodynamics were evaluated at rest and during exercise with a patient-specific model from magnetic resonance imaging data together with computational fluid dynamics. Four clinically motivated performance measures were examined: Fontan pressures, energy efficiency, inferior vena cava flow distribution, and wall shear stress. Two variants of the Y-graft were evaluated: an “off-the-shelf” graft with 9-mm branches and an “area-preserving” graft with 12-mm branches.ResultsEnergy efficiency of the 12-mm Y-graft was higher than all other models at rest and during exercise, and the reduction in efficiency from rest to exercise was improved by 38%. Both Y-graft designs reduced superior vena cava pressures during exercise by as much as 5 mm Hg. The Y-graft more equally distributed the inferior vena cava flow to both lungs, whereas the offset design skewed 70% of the flow to the left lung. The 12-mm graft resulted in slightly larger regions of low wall shear stress than other models; however, minimum shear stress values were similar.ConclusionsThe area-preserving 12-mm Y-graft is a promising modification of the Fontan procedure that should be clinically evaluated. Further work is needed to correlate our performance metrics with clinical outcomes, including exercise intolerance, incidence of protein-losing enteropathy, and thrombus formation

    Sex differences in patients with repaired tetralogy of Fallot support a tailored approach for males and females:a cardiac magnetic resonance study

    Get PDF
    Purpose Substantial differences between sexes exist with respect to cardiovascular diseases, including congenital heart disease. Nevertheless, clinical decisions in the long-term follow-up of patients with repaired tetralogy of Fallot (rTOF) are currently based on unisex thresholds for cardiac magnetic resonance (CMR) measurements. This study aimed to assess whether sex differences exist in cardiac adaptation to hemodynamic loading conditions in patients with rTOF. Methods and Results This cross-sectional, two-center, combined pediatric and adult cohort included 320 rTOF patients (163 males, 51%) who underwent routine CMR. Despite similar age (median and interquartile range [m + IQR] 23.4 [15.2-34.4] years), surgical history, and hemodynamic loading, males with rTOF demonstrated higher biventricular CMR-derived volumes and masses, indexed for body surface area, compared to females (e.g. m + IQR right ventricular (RV) end-diastolic volume: males 123 [100-151] mL/m2, females 114 [94-131] mL/m2, P = 0.007). Sex-specific Z-scores of biventricular volumes and masses were similar for males and females. RV volumes and masses correlated with hemodynamic loading, but these relations did not differ between sexes. Biventricular ejection fraction (EF) appeared to be lower in male patients, compared to female patients (e.g. m + IQR RVEF: males 48 [43-54]%, females 52 [46-57]%, P < 0.001). Conclusion Indexed ventricular volumes and masses are higher in males with rTOF, compared to females, similar to the healthy population. RV hypertrophy and dilatation correlated to loading conditions similarly for both sexes. However, under comparable loading conditions, males demonstrated more severe functional impairment. These results indicate that sex-differences should no longer be ignored in treatment strategies, including timing of pulmonary valve replacement

    Computational simulation of postoperative pulmonary flow distribution in Alagille patients with peripheral pulmonary artery stenosis

    No full text
    International audienceBackgroundUp to 90% of individuals with Alagille syndrome have congenital heart diseases. Peripheral pulmonary artery stenosis (PPS), resulting in right ventricular hypertension and pulmonary flow disparity, is one of the most common abnormalities, yet the hemodynamic effects are ill-defined, and optimal patient management and treatment strategies are not well established. The purpose of this pilot study is to use recently refined computational simulation in the setting of multiple surgical strategies, to examine the influence of pulmonary artery reconstruction on hemodynamics in this population.Materials and MethodsBased on computed tomography angiography and cardiac catheterization data, preoperative pulmonary artery models were constructed for 4 patients with Alagille syndrome with PPS (all male, age range: 0.6–2.9 years), and flow simulations with deformable walls were performed. Surgeon directed virtual surgery, mimicking the surgical procedure, was then performed to derive postoperative models. Postoperative simulation-derived hemodynamics and blood flow distribution were then compared with the clinical results.ResultsSimulations confirmed substantial resistance, resulting from preoperative severe ostial stenoses, and the use of newly developed adaptive outflow boundary conditions led to excellent agreement with in vivo measurements. Relief of PPS decreased pulmonary artery pressures and improved pulmonary flow distribution both in vivo and in silico with good correlation.ConclusionsUsing adaptive outflow boundary conditions, computational simulations can estimate postoperative overall pulmonary flow distribution in patients with Alagille syndrome after pulmonary artery reconstruction. Obstruction relief along with pulmonary artery vasodilation determines postoperative pulmonary flow distribution and newer methods can incorporate these physiologic changes. Evolving blood flow simulations may be useful in surgical or transcatheter planning and in understanding the complex interplay among various obstructions in patients with peripheral pulmonary stenosis

    Computational simulations demonstrate altered wall shear stress in aortic coarctation patients treated by resection with end-to-end anastomosis.

    No full text
    International audienceBACKGROUND: Atherosclerotic plaque in the descending thoracic aorta (dAo) is related to altered wall shear stress (WSS) for normal patients. Resection with end-to-end anastomosis (RWEA) is the gold standard for coarctation of the aorta (CoA) repair, but may lead to altered WSS indices that contribute to morbidity. METHODS: Computational fluid dynamics (CFD) models were created from imaging and blood pressure data for control subjects and age- and gender-matched CoA patients treated by RWEA (four males, two females, 15 ± 8 years). CFD analysis incorporated downstream vascular resistance and compliance to generate blood flow velocity, time-averaged WSS (TAWSS), and oscillatory shear index (OSI) results. These indices were quantified longitudinally and circumferentially in the dAo, and several visualization methods were used to highlight regions of potential hemodynamic susceptibility. RESULTS: The total dAo area exposed to subnormal TAWSS and OSI was similar between groups, but several statistically significant local differences were revealed. Control subjects experienced left-handed rotating patterns of TAWSS and OSI down the dAo. TAWSS was elevated in CoA patients near the site of residual narrowings and OSI was elevated distally, particularly along the left dAo wall. Differences in WSS indices between groups were negligible more than 5 dAo diameters distal to the aortic arch. CONCLUSIONS: Localized differences in WSS indices within the dAo of CoA patients treated by RWEA suggest that plaque may form in unique locations influenced by the surgical repair. These regions can be visualized in familiar and intuitive ways allowing clinicians to track their contribution to morbidity in longitudinal studies
    corecore